    INSTALLATION C3419M-D (11/08) In-Ceiling Back Box Heavy Duty Spectra ® IV Series ...

  • Schneider Electric C3419M-D (11/08) - page 2

    2 C3419M-D (11/08) Installation BACK MOUNTING PLA TES  MOUNTING RING  CEILING  NOT S UPPLIED 1 5 36 4 2 ...

  • Schneider Electric C3419M-D (11/08) - page 3

    C3419M-D (11/08) 3 1. Locate the center point of the mounting location and insert the compass tool into the ceili ng. Draw a c ircle. 2. Cut out the circle. 3. Use the mounting ring as a template to mark the screw hole pattern onto th e mounting surface. Prepare the holes. 4. Install the mounting plat es. Use the eight 10-32 x 3-inch screws (suppl ...

  • Schneider Electric C3419M-D (11/08) - page 4

    4 C3419M-D (11/08) 7 8 VIDEO UTP+ UTP- RX- RX+ TX+ TX- PWR- PWR+ GND AUX2 GND GND NO NC COM 7 6 5 4 3 2 1 ALARMS AUX1 ...

  • Schneider Electric C3419M-D (11/08) - page 5

    C3419M-D (11/08) 5 7. Install the back box by compressing the sp ring clips and pushing t he back box through the hole. T ighten the sc rews until you he ar a clicki ng noise. 8. Connect the wiring to t he circuit b oard inside th e back box. Whe n finished, clo se the door to the back bo x and turn on the power . The green LED will glow. NOTES: ? ...

  • Schneider Electric C3419M-D (11/08) - page 6

    6 C3419M-D (11/08) TRIM LEASH  BALL STUD  BALL STUD RECEIVER  BARREL KEY LOCK  SWITCH 1 AND 2 11 9 10 ...

  • Schneider Electric C3419M-D (11/08) - page 7

    C3419M-D (11/08) 7 9. Configure D IP switches SW1 and SW2 located on the top of the dome drive. For DIP switch se ttings, refer to the labels located on the to p of the dome drive or to Switch Settings on page 8. NOTE: When connecting mo re than one Spectra ® dome to a single controller , te rminate the unit farthest fr om the controller . T o ter ...

  • Schneider Electric C3419M-D (11/08) - page 8

    8 C3419M-D (11/08) Switch Settings WAR N I N G: If you are using Pelco D-type or P-t ype control, your system may not operat e if the baud rate and address swi tches are n ot set corr ectly . The swit ches are set at the fac tory at the d efaults fo r Pelco D- type contr ol (2400 baud and address 1). T able E. Switch Settings for SW2 Special System ...

  • Schneider Electric C3419M-D (11/08) - page 9

    C3419M-D (11/08) 9 T able F . Switch Settings for SW1, P- T y pe Control NOTE: For Coaxitron con trols, SW1 is not used; se t all switch es to OFF . For D-type co ntrol systems, refer to T able G. T able G. Switch Settings for SW1, D-T y pe Control NOTE: For Coaxitron con trols, SW1 is not used ; set all switch es to OFF . For P-type control system ...

  • Schneider Electric C3419M-D (11/08) - page 10

    10 C3419M-D (11/08) SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 71 ON ON ON OFF OFF OFF ON O FF 72 OFF OFF OFF ON OFF OFF ON OFF 73 ON OFF OFF ON OFF OFF ON OFF 74 OFF ON OFF ON OFF OFF ON OFF 75 ON ON OFF ON OFF OFF ON OFF 76 OFF OFF ON ON OFF OFF ON OFF 77 ON OFF ON ON OFF OFF ON OFF 78 OFF ON ON ON OFF OFF ON ...

  • Schneider Electric C3419M-D (11/08) - page 11

    C3419M-D (11/08) 11 SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 151 ON ON ON OFF ON OFF OFF ON 152 OFF OFF OFF ON ON OFF OFF ON 153 ON OFF OFF ON ON OFF OFF ON 154 OFF ON OFF ON ON OFF OFF ON 155 ON ON OFF ON ON OFF OFF ON 156 OFF OFF ON ON ON OFF OFF ON 157 ON OFF ON ON ON OFF OFF ON 158 OFF ON ON ON ON OFF OFF ...

  • Schneider Electric C3419M-D (11/08) - page 12

    12 C3419M-D (11/08) SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF O FF OFF ON ON ON 228 OFF OFF ON OFF OFF ON ON ON 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON ON OFF OFF ON ON O ...

  • Schneider Electric C3419M-D (11/08) - page 13

    C3419M-D (11/08) 13 Specifications GENERAL Construction Back Box Aluminum Dome Drive Aluminum, thermoplasti c Lower Dome Clear polycarb onate, 0.090-inch thick Cage Thicknes s 0.12 x 0.30- inch cast sta inless steel Cage Color Black, for maximum discreetness Cable Entry (Back Box) 0.75-inch co nduit fitti ng Pan Movement 360° contin uous pan rotat ...

  • Schneider Electric C3419M-D (11/08) - page 14

    14 C3419M-D (11/08) The materials used in the manufacture of this document and its co mponents are compliant to the requirements of Directive 2002/9 5/EC. This equipment contains electrical or electronic components that mu st be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical an ...

  • Schneider Electric C3419M-D (11/08) - page 15

    PRODUCT W ARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or repl ace, without c harge, any merc handise proved defective in material or workmanshi p for a period of one year after the date of shipment. Exceptions to this warranty are as noted b elow: • Five year s: – Fiber optic prod ucts – TW3000 Series unshield ed twisted pair ( ...

  • Schneider Electric C3419M-D (11/08) - page 16

    Pelco, Inc. W orldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el (800) 289-9100 Fax (800) 289-9150 International T el +1 (559) 29 2-1981 Fax +1 (559) 348-1120 www .pelco.com ...

Produzent Schneider Electric Kategorie Webcam

Dokumente, die wir vom Produzenten des Geräts Schneider Electric C3419M-D (11/08) erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Schneider Electric
- Bedienungsanleitungen C3419M-D (11/08)
- Produktkarten Schneider Electric
- Informationsbroschüren
- oder Energieetiketten Schneider Electric C3419M-D (11/08)
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Schneider Electric C3419M-D (11/08).

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Schneider Electric C3419M-D (11/08), Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Schneider Electric C3419M-D (11/08). Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Schneider Electric C3419M-D (11/08) ansehen.

Die komplette Bedienungsanleitung des Geräts Schneider Electric C3419M-D (11/08), wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Schneider Electric C3419M-D (11/08) hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Schneider Electric C3419M-D (11/08) verständlich ist.

Eine gänzliche Bedienungsanleitung von Schneider Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Schneider Electric C3419M-D (11/08) bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Schneider Electric C3419M-D (11/08) befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Schneider Electric C3419M-D (11/08), die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Schneider Electric C3419M-D (11/08) - die uns die ersten Schritte während der Nutzung von Schneider Electric C3419M-D (11/08) erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Schneider Electric C3419M-D (11/08) hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Schneider Electric C3419M-D (11/08) im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Schneider Electric C3419M-D (11/08)?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Schneider Electric C3419M-D (11/08) nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Schneider Electric C3419M-D (11/08) hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)