Manuel d’utilisation Schneider Electric C3419M-D (11/08)

16 pages 1.4 mb
Télécharger

Aller à la page of 16

Summary
  • Schneider Electric C3419M-D (11/08) - page 1

    INSTALLATION C3419M-D (11/08) In-Ceiling Back Box Heavy Duty Spectra ® IV Series ...

  • Schneider Electric C3419M-D (11/08) - page 2

    2 C3419M-D (11/08) Installation BACK MOUNTING PLA TES  MOUNTING RING  CEILING  NOT S UPPLIED 1 5 36 4 2 ...

  • Schneider Electric C3419M-D (11/08) - page 3

    C3419M-D (11/08) 3 1. Locate the center point of the mounting location and insert the compass tool into the ceili ng. Draw a c ircle. 2. Cut out the circle. 3. Use the mounting ring as a template to mark the screw hole pattern onto th e mounting surface. Prepare the holes. 4. Install the mounting plat es. Use the eight 10-32 x 3-inch screws (suppl ...

  • Schneider Electric C3419M-D (11/08) - page 4

    4 C3419M-D (11/08) 7 8 VIDEO UTP+ UTP- RX- RX+ TX+ TX- PWR- PWR+ GND AUX2 GND GND NO NC COM 7 6 5 4 3 2 1 ALARMS AUX1 ...

  • Schneider Electric C3419M-D (11/08) - page 5

    C3419M-D (11/08) 5 7. Install the back box by compressing the sp ring clips and pushing t he back box through the hole. T ighten the sc rews until you he ar a clicki ng noise. 8. Connect the wiring to t he circuit b oard inside th e back box. Whe n finished, clo se the door to the back bo x and turn on the power . The green LED will glow. NOTES: ? ...

  • Schneider Electric C3419M-D (11/08) - page 6

    6 C3419M-D (11/08) TRIM LEASH  BALL STUD  BALL STUD RECEIVER  BARREL KEY LOCK  SWITCH 1 AND 2 11 9 10 ...

  • Schneider Electric C3419M-D (11/08) - page 7

    C3419M-D (11/08) 7 9. Configure D IP switches SW1 and SW2 located on the top of the dome drive. For DIP switch se ttings, refer to the labels located on the to p of the dome drive or to Switch Settings on page 8. NOTE: When connecting mo re than one Spectra ® dome to a single controller , te rminate the unit farthest fr om the controller . T o ter ...

  • Schneider Electric C3419M-D (11/08) - page 8

    8 C3419M-D (11/08) Switch Settings WAR N I N G: If you are using Pelco D-type or P-t ype control, your system may not operat e if the baud rate and address swi tches are n ot set corr ectly . The swit ches are set at the fac tory at the d efaults fo r Pelco D- type contr ol (2400 baud and address 1). T able E. Switch Settings for SW2 Special System ...

  • Schneider Electric C3419M-D (11/08) - page 9

    C3419M-D (11/08) 9 T able F . Switch Settings for SW1, P- T y pe Control NOTE: For Coaxitron con trols, SW1 is not used; se t all switch es to OFF . For D-type co ntrol systems, refer to T able G. T able G. Switch Settings for SW1, D-T y pe Control NOTE: For Coaxitron con trols, SW1 is not used ; set all switch es to OFF . For P-type control system ...

  • Schneider Electric C3419M-D (11/08) - page 10

    10 C3419M-D (11/08) SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 71 ON ON ON OFF OFF OFF ON O FF 72 OFF OFF OFF ON OFF OFF ON OFF 73 ON OFF OFF ON OFF OFF ON OFF 74 OFF ON OFF ON OFF OFF ON OFF 75 ON ON OFF ON OFF OFF ON OFF 76 OFF OFF ON ON OFF OFF ON OFF 77 ON OFF ON ON OFF OFF ON OFF 78 OFF ON ON ON OFF OFF ON ...

  • Schneider Electric C3419M-D (11/08) - page 11

    C3419M-D (11/08) 11 SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 151 ON ON ON OFF ON OFF OFF ON 152 OFF OFF OFF ON ON OFF OFF ON 153 ON OFF OFF ON ON OFF OFF ON 154 OFF ON OFF ON ON OFF OFF ON 155 ON ON OFF ON ON OFF OFF ON 156 OFF OFF ON ON ON OFF OFF ON 157 ON OFF ON ON ON OFF OFF ON 158 OFF ON ON ON ON OFF OFF ...

  • Schneider Electric C3419M-D (11/08) - page 12

    12 C3419M-D (11/08) SPECTRA ADDRESS SWITCH SETTI NG SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF O FF OFF ON ON ON 228 OFF OFF ON OFF OFF ON ON ON 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON ON OFF OFF ON ON O ...

  • Schneider Electric C3419M-D (11/08) - page 13

    C3419M-D (11/08) 13 Specifications GENERAL Construction Back Box Aluminum Dome Drive Aluminum, thermoplasti c Lower Dome Clear polycarb onate, 0.090-inch thick Cage Thicknes s 0.12 x 0.30- inch cast sta inless steel Cage Color Black, for maximum discreetness Cable Entry (Back Box) 0.75-inch co nduit fitti ng Pan Movement 360° contin uous pan rotat ...

  • Schneider Electric C3419M-D (11/08) - page 14

    14 C3419M-D (11/08) The materials used in the manufacture of this document and its co mponents are compliant to the requirements of Directive 2002/9 5/EC. This equipment contains electrical or electronic components that mu st be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical an ...

  • Schneider Electric C3419M-D (11/08) - page 15

    PRODUCT W ARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or repl ace, without c harge, any merc handise proved defective in material or workmanshi p for a period of one year after the date of shipment. Exceptions to this warranty are as noted b elow: • Five year s: – Fiber optic prod ucts – TW3000 Series unshield ed twisted pair ( ...

  • Schneider Electric C3419M-D (11/08) - page 16

    Pelco, Inc. W orldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el (800) 289-9100 Fax (800) 289-9150 International T el +1 (559) 29 2-1981 Fax +1 (559) 348-1120 www .pelco.com ...

Fabricant Schneider Electric Catégorie Webcam

Les documents que nous recevons du fabricant de l'appareilSchneider Electric C3419M-D (11/08) peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Schneider Electric
- manuels d’utilisations C3419M-D (11/08)
- fiches produit Schneider Electric
- dépliants
- ou étiquettes-énergie Schneider Electric C3419M-D (11/08)
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Schneider Electric C3419M-D (11/08).

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Schneider Electric C3419M-D (11/08), manuels d’entretien, brefs manuels ou manuels de l’utilisateur Schneider Electric C3419M-D (11/08). Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Schneider Electric C3419M-D (11/08).

Manuel d’utilisation complet de l’appareil Schneider Electric C3419M-D (11/08), quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Schneider Electric C3419M-D (11/08) par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Schneider Electric C3419M-D (11/08).

Le manuel d’utilisation complet Schneider Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Schneider Electric C3419M-D (11/08) - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Schneider Electric C3419M-D (11/08), FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSchneider Electric C3419M-D (11/08) qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Schneider Electric C3419M-D (11/08) - qui devraient nous aider dans les premières étapes lors de l'utilisation Schneider Electric C3419M-D (11/08)
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Schneider Electric C3419M-D (11/08)
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Schneider Electric C3419M-D (11/08) dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Schneider Electric C3419M-D (11/08)?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Schneider Electric C3419M-D (11/08), avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Schneider Electric C3419M-D (11/08) il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)