  • Miller Electric OM-2219 - page 1

    Visit our website at www.M il ler Weld s.c om OM -2219 188 036G October 1999 Processes Processes Descrip tio n Air Plasma Cutting and Gouging Air Plasma Cutter Spectrum L ynx R ...

  • Miller Electric OM-2219 - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .MillerW eld ...

  • Miller Electric OM-2219 - page 3

    T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Plasma Arc Cutting Hazards 1 . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric OM-2219 - page 4

    ...

  • Miller Electric OM-2219 - page 5

    OM-2219 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING pom _nd_9/98 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means W arning! Watch ...

  • Miller Electric OM-2219 - page 6

    OM-2219 Page 2 D On inverter power sources, failed parts can ex- plode or cause other parts to explode when power is applied. Always wear a face shield and long sleeves when servicing inverters. EXPLODING P ARTS can injure. Sparks and hot metal blow out from the cutting arc. Chipping and grinding cause flying metal. FL YING SP ARKS can cause injury ...

  • Miller Electric OM-2219 - page 7

    OM-2219 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance HOT P ARTS can cause severe burns. D Do not touch hot parts bare handed. D Allow cooling period before working on torch. MOVING P ARTS can cause injury . D Keep away from moving parts such as fans. D Keep all doors, panels, covers, and guards closed and securely in ...

  • Miller Electric OM-2219 - page 8

    OM-2219 Page 4 1-4. Principal Safety Standards Safety in Welding and Cutting , ANSI Standard Z49.1, from American W elding Society , 550 N.W . LeJeune Rd, Miami FL 33126 Safety and Health Standards , OSHA 29 CFR 1910, from Superinten- dent o f Documents, U.S. Government Printing Of fice, Washington, D.C. 20402. Recommended Practices for Plasma Arc ...

  • Miller Electric OM-2219 - page 9

    OM-2219 Page 5 SECTION 1 – CONSIGNES DE S É CURIT É – LIRE A V ANT UTILISA TION pom_nd_fre_5/97 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives. Y Identifie un message de s é curit é particuli ...

  • Miller Electric OM-2219 - page 10

    OM-2219 Page 6 D N ’ approchez pas le tube du chalumeau et l ’ arc pilote lorsque la g â chette est enfonc é e. D Le c â ble de masse doit ê tre pinc é correctement sur la pi è ce à couper , m é tal contre m é tal (et non de telle sorte qu ’ il puisse se d é tacher), ou sur la table de travail le plus pr è s possible de la ligne de ...

  • Miller Electric OM-2219 - page 11

    OM-2219 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance DES PIECES CHAUDES peuvent pro- voquer des br û lures graves. D Ne pas toucher des parties chaudes à mains nues. D Laisser refroidir avant d ’ intervenir sur la torche. DES ORGANES MOBILES peuvent provoquer des blessures. D S ...

  • Miller Electric OM-2219 - page 12

    OM-2219 Page 8 1-4. Principales normes de s é curit é Safety in W elding and Cutting, norme ANSI Z49.1, de l ’ American W el- ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Of fice, Washington, D.C. 20402. Recommended Safe Practice for th ...

  • Miller Electric OM-2219 - page 13

    OM-2219 Page 9 SECTION 2 – INST ALLA TION 2-1. Specifications Rated Cutting Maximum Open- T ype of Output Plasma Gas Rated Output Rated Cutting Capacity Maximum Open- Circuit V oltage DC Direct Current, Straight 50 A @ 1 10 V olts DC, 0.7 in (16 mm) Direct Current, Straight Polarity (DCEN) Air Or Nitrogen Only 50 A @ 1 10 V olts DC, 50% Duty Cycl ...

  • Miller Electric OM-2219 - page 14

    OM-2219 Page 10 2-4. Selecting A Location loc_2 3/96 - ST-801 976 1 Lifting Handles Use handles to lift unit. 2 Hand Cart Use cart or similar device to move unit. Y Special installation may be required where gasoline or volatile liquids are present – see NEC Article 51 1 or CEC Section 20 . Dimensions And W eight 1 2 Y Do not move or operate unit ...

  • Miller Electric OM-2219 - page 15

    OM-2219 Page 1 1 2-5. Connecting W ork Clamp And Gas/Air Supply Ref. 801 977-A 1 Work Clamp 2 W orkpiece W ork clamp cable is attached to front o f unit. Connect work clamp to a clean, paint-free location on work- piece, as close to cutting area as possible. . Use only clean, dry air with 90 to 150 psi pressure. 3 Gas/Air Inlet Opening 4 Hose 5 T e ...

  • Miller Electric OM-2219 - page 16

    OM-2219 Page 12 SECTION 3 – OPERA TION If the welding generator includes a fine adjust control, be sure to set the control to maximum for full output control capacity . When using the Lynx, auxiliary power output is not available from the 120 or 240 V AC receptacles on the welding generator . NOTE 3-1. Controls Ref. ST -189 734 / Ref. 801 977 – ...

  • Miller Electric OM-2219 - page 17

    OM-2219 Page 13 1 Output Control 2 Power Switch Place controls as indicated above. Only gas/ air circuit is activated when the Power switch is turned On with Output Control in Gas/Air Set position. 3 Gas/Air Pressure Adjustment Knob Pull knob and turn to adjust pressure. Push knob in to lock setting. Select desired cutting output with Output Contro ...

  • Miller Electric OM-2219 - page 18

    OM-2219 Page 14 3-3. Sequence Of Operation Put On Personal Safety Equipment After cutting arc starts, slowly start moving torch across metal. Adjust torch speed so sparks go thru metal and out bottom of cut. Pause briefly at end of cut before releasing trigger . Install & Connect Equipment EXAMPLE Of Cutting Operation ST-801 400-A Press trigger ...

  • Miller Electric OM-2219 - page 19

    OM-2219 Page 15 SECTION 4 – MAINTENANCE & TROUBLESHOOTING 4-1. Routine Maintenance Y Disconnect power before maintaining. . Maintain more often during severe conditions. Each Use Check T orch T ip, Electrode, And Shield Cup Check Gas/Air Pressure Every Week Check Shield Cup Shutdown System 3 Months Service A i r Filter/Regulator Assembly Filt ...

  • Miller Electric OM-2219 - page 20

    OM-2219 Page 16 4-2. Ground Fault Circuit Interrupter (GFCI) Ref. 801 977-A / Ref. 802 180-A 1 Ground Fault Circuit Interrupter GFCI 2 Spring-Loaded Door (Shown Open) GFCI provides ground fault protec- tion for the input power connection. If a ground fault is detected, GFCI RESET button pops out and the unit will not function. Press button to reset ...

  • Miller Electric OM-2219 - page 21

    OM-2219 Page 17 4-3. T rouble Lights 1 Pressure Light Lights if gas/air pressure is below 40 PSI (276 kPa). Tur n power Of f, and check for prop- er gas/air pressure (see Section 3-2). 2 Cup Light Lights if shield cup is loose. T urn power Of f, and check shield cup connection (see torch Owner ’ s Manual). Power must be reset whenever the cup shu ...

  • Miller Electric OM-2219 - page 22

    OM-2219 Page 18 T rouble Remedy No cutting output; Power light of f; T rouble lights of f; Ready light o f f; fan mo- tor FM does not run. Place Power switch in On position. Reset welding generator circuit breaker CB1 and/or CB2. Check power plug connection at welding generator . Have Factory Authorized Service Agent check power switch S1, transfor ...

  • Miller Electric OM-2219 - page 23

    OM-2219 Page 19 SECTION 5 – ELECTRICAL DIAGRAM 193 622 Figure 5-1. Circuit Diagram ...

  • Miller Electric OM-2219 - page 24

    OM-2219 Page 20 SECTION 6 – P ARTS LIST . Hardware is common and not available unless listed. 802 180-C 1 2 3 4 6 7 8 9 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 48 49 50 5 47 53 54 51 51 52 57 55 55 56 19 Figure 6-1. Complete Assembly ...

  • Miller Electric OM-2219 - page 25

    OM-2219 Page 21 Description Part No. Dia. Mkgs. Item No. Figure 6-1. Complete Assembly Quantity 1 187 782 WRAPPER 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 126 416 HANDLE, molded 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric OM-2219 - page 26

    OM-2219 Page 22 Description Part No. Dia. Mkgs. Item No. Figure 6-1. Complete Assembly (continued) Quantity 51 138 442 LABEL, caution falling equipment 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 178 739 FITTING, plastic straight fem 1/8 NPT 1 . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric OM-2219 - page 27

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 7/00 Y ou r distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise ...

  • Miller Electric OM-2219 - page 28

    PRINTED IN USA  2000 Miller Electric Mfg. Co. 6/00 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Company 1635 West Spencer St reet Applet on, WI 54914 USA International He adquarters – USA USA Phone: 920-735-4505 Aut o-At t ended USA & C anada FAX: 920-735-4134 Int ernati onal F A X : 920-735-4125 European H eadqua rters – United ...

Produzent Miller Electric Kategorie Welder

Dokumente, die wir vom Produzenten des Geräts Miller Electric OM-2219 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Miller Electric
- Bedienungsanleitungen OM-2219
- Produktkarten Miller Electric
- Informationsbroschüren
- oder Energieetiketten Miller Electric OM-2219
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Miller Electric OM-2219.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Miller Electric OM-2219, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Miller Electric OM-2219. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Miller Electric OM-2219 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Miller Electric OM-2219, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Miller Electric OM-2219 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Miller Electric OM-2219 verständlich ist.

Eine gänzliche Bedienungsanleitung von Miller Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Miller Electric OM-2219 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Miller Electric OM-2219 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Miller Electric OM-2219, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Miller Electric OM-2219 - die uns die ersten Schritte während der Nutzung von Miller Electric OM-2219 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Miller Electric OM-2219 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Miller Electric OM-2219 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Miller Electric OM-2219?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Miller Electric OM-2219 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Miller Electric OM-2219 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen