  • Dell 40G - page 1

    Victor Teeter Network Enabled Solutions Team Stacking Dell For ce10 MXL 10/40G Blade Switches ...

  • Dell 40G - page 2

    Stacking Dell Force10 MXL 10/ 40G Blade Switches v1.1 ii This document is f or informational pu rposes only and may cont ain typographical er rors and technical inaccuracies . The content is p rovided as is, withou t express or implied war ranties of any kind. © 2012 Dell Inc . All rights reserved. De ll and its affiliates cannot be responsible fo ...

  • Dell 40G - page 3

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 1 Contents Introduction ................................ ............................................................................. 3 Redundancy ........................................................................................................... 4 Failover roles .............. ...

  • Dell 40G - page 4

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 2 ...

  • Dell 40G - page 5

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 3 Introduction Numerous Dell ™ swi tches include a sta cking feature t hat allows multiple physica l switches to operate as a single logical s witch, p roviding a consolidated int erface for manag ement . T he Dell Force10 MXL 10/40 Gb switch is the latest Dell switch with this featur ...

  • Dell 40G - page 6

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 4 Additional stack mem bers can immedia tely utilize existing co nfiguration informatio n such as routing and switching configurati ons, VLANs, ACLs , port profil es, and security ce rtificates. Redundancy By connecting a ca ble from the last swi tch in a stack back to th e first switch ...

  • Dell 40G - page 7

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 5 Another way to comp letely wipe out a ll configurations and r eturn to factory def aults is to erase the meta-data (NVRAM) a nd delete th e startup configura tion by following th e instructions i n Restoring factory defaults be low. Restoring factor y defaults Usually a standalo ne MX ...

  • Dell 40G - page 8

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 6 no ip address shutdown ! interface TenGigabit Ethernet 0/2 no ip address -- More -- Additional stack -unit lines like t he one below may be fo und in an unstacked MX L if one or more expansion mod ules are present. In order to us e these ports f or stacking the qua d mode will need to ...

  • Dell 40G - page 9

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 7 Port numbering When installed in a Pow erEdge ™ M1000e Enclosure, th e MXL 10/40GbE external swi tch ports are numbered 33 to 56 from the bottom to th e top of the swi tch (ports 1-32 are inte rnal 10G ports): • 40GbE base -mod ule (built -in) ports:  In 2x 40GbE mode of operat ...

  • Dell 40G - page 10

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 8 Combining split 10GbE SFP+ ports into a single 40GbE QSFP+ p ort The MXL 10/40GbE Swit ch supports splittin g each 40G bE port on the base module or a 2 -Port 40GbE QSFP+ expansion mo dule into eight 10GbE SFP+ ports using a break out cable. However, ports must b e combined in to sing ...

  • Dell 40G - page 11

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 9 listed here whe n in port mode. If there is no “sta ck - unit” listing for t he first port number, then the po rts are not split and ar e running at 4 0 GbE. 2. interface fortyGigE 0/33 : interface TenG igabitEthernet 0/41 Each individual port mode is listed furt her down in th e ...

  • Dell 40G - page 12

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 10 Status : on line Next Boot : online Required Type : MXL -10/4 0GbE - 34 -port GE/TE/FG (X L) Current Type : MXL-10/40GbE - 34 -port GE/TE/FG (XL) Master priority : 0 Hardware Rev : X00 Num Ports : 56 Up Time : 1 wk , 3 day, 23 hr , 5 min FTOS Version : 8.3 .16.0E0 Jumbo Capable : y e ...

  • Dell 40G - page 13

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 11 QSFP+ built-in ports a re set to 40 Gb by default whi le expansion mo dule QSFP+ p orts are set to 10 Gb ports by default. To c hange a port from 1 0 Gb mode to 40 Gb mode, use the command FTOS(conf)# no sta ck-unit 0 port p portmode quad Please save and re load for the chang es to t ...

  • Dell 40G - page 14

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 12 Stacking multip le M XL swit ches in a single M1 000e Figure 5. Dell M1000e Blade Chassis B2 C2 A2 B1 C1 A1 4 1 7 5 2 8 6 3 9 CMC2 CMC1 KVM 123456 Gb Gb 2 1 CMC iKVM Gb Gb 2 1 CMC MXL Stack CONSOLE 33-36 37-40 LNK ACT LNK ACT Force10 MXL 10/40GbE 41-48 49-56 CONSOLE 33-36 37-40 LNK A ...

  • Dell 40G - page 15

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 13 The Dell M1000e Se rver Chassi s includes a manag ement console port on the CMC tha t allows a llows management of eac h module from a s ingle serial conn ection to the chassis. Fo r more information , see the Dell Blade Se rver CMC User 's Guide at http://support.dell.co m/supp ...

  • Dell 40G - page 16

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 14 FTOS# show invento ry optional- module Unit Slot Expecte d Inserted N ext Boot Power ------ ----- ------- -------- ------------- ------- -------- ----- ------ 0 0 Q SFP+ QSFP+ AUTO Good 0 1 QSF P+ QSFP+ AUT O Good In this example, sta ck-groups 2 thru 5 correspond to two 40G QSFP+ ex ...

  • Dell 40G - page 17

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 15 Note: When creating s tack ports on an MXL, all ports must be fixed or on the ex pansion module. Mixi ng fixed and expansion mod ule ports in o rder to stack is not supported. Maximum st ack-group per unit A maximum of 4 stack-groups per unit can be configured. In a ring topology, th ...

  • Dell 40G - page 18

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 16 1 Standby o nline MXL - 10/40G bE MXL-10/40GbE 8 .3.16.0E0 56 2 Member on line MXL -10/40GbE MXL -10/40GbE 8 .3.16.0E0 56 3 Member on line MXL -10/40GbE MX L-10/40GbE 8 .3.16.0E0 56 4 Member on line MXL -10/40GbE MXL -10/40GbE 8 .3.16.0E0 56 5 Member on line MXL -10/40GbE MXL -10/40G ...

  • Dell 40G - page 19

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 17 FTOS(conf)# sta ck-unit 1 provision ? MXL-10/40GbE 34-po rt GE/TE/FG (XL) FTOS(conf)# sta ck-unit 1 provision MXL -10/40GbE Certain configurati on changes on th e unit suc h as “fanout” and “stack - grou ps” may require sav ing and reloading the e ntire stack. Refer to the M ...

  • Dell 40G - page 20

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 18 the downloaded image is distributed to all mem ber units of the stack . The inst ructions below wi ll guide the user thro ugh these steps. Note: When upgradi ng a stack of swi tches, allow extra ti me betw een upgrade st eps for files and configurations to be co pied from the Master ...

  • Dell 40G - page 21

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 19 Image upgraded to a ll 4. Verify the new firmware w as copied to all sta ck members. FTOS# show boot syste m stack- unit all Current system ima ge information in th e system: =========== ======= ========== ================= Type Boot Typ e A B ------ ----- ------- -------- ----- ---- ...

  • Dell 40G - page 22

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 20 FTOS# show boot syste m stack- unit all Current system ima ge information in th e system: =========== ======= ========== ================= Type Boot Typ e A B ------ ----- ------- -------- ----- -------- ----- ------- -------- ----- Stack-unit 0 FLASH BOOT 8.3 .15.0 8 -3- 16 -0[boot] ...

  • Dell 40G - page 23

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 21 FTOS(conf)# no sta ck-unit 2 st ack-group 0 FTOS(conf)# no sta ck-unit 2 st ack-group 1 FTOS(conf)# no sta ck-unit 2 st ack-group 2 FTOS(conf)# no sta ck-unit 2 st ack-group 3 : : FTOS(conf)# no sta ck-unit 5 st ack-group 2 FTOS(conf)# no sta ck-unit 5 st ack-group 3 FTOS(conf)# exit ...

  • Dell 40G - page 24

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 22 FTOS# stack-unit 1 renumber 5 % ERROR: stack unit 5 already exis ts. If the new number a ssign ment is already used b y a logi cally provisi oned u nit in the stack, t he be low confirmation message to overwrite is dis played. FTOS# stack-unit 1 renumbe r 5 Stack unit 5 has configura ...

  • Dell 40G - page 25

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 23 Appendix A – Sta cking scenarios When creating s tack ports o n an MXL, all ports must be fixed or on the expansio n module. Mixing fix ed and expansion mod ule ports i n order to stack is not su pported. * When there a re six QSFP+ ports available on the swit ch, a max imum of 4 p ...

  • Dell 40G - page 26

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 24 Appendix B – Port mapping ...

  • Dell 40G - page 27

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 25 Appendix C - Net work switch vers ions Version information for t he network switc hes used i n creating this docum ent are as f ollows: Network switch Dell Force10 XML Software version 8.3.16.0, E8.3.16.163 , E8.3.16.0E0 ...

Fabricante Dell Categoría Switch

Los documentos del dispositivo Dell 40G que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Dell
- manuales de instrucciones 40G
- hojas de producto Dell
- folletos informativos
- o etiquetas energéticas Dell 40G
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Dell 40G.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Dell 40G, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Dell 40G. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Dell 40G.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Dell 40G, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Dell 40G. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Dell 40G.

El manual de instrucciones completo de Dell debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Dell 40G - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Dell 40G, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Dell 40G que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Dell 40G - que deben facilitarnos los primeros pasos durante el uso de Dell 40G
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Dell 40G
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Dell 40G en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Dell 40G?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Dell 40G, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Dell 40G probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)