    Victor Teeter Network Enabled Solutions Team Stacking Dell For ce10 MXL 10/40G Blade Switches ...

  • Dell 40G - page 2

    Stacking Dell Force10 MXL 10/ 40G Blade Switches v1.1 ii This document is f or informational pu rposes only and may cont ain typographical er rors and technical inaccuracies . The content is p rovided as is, withou t express or implied war ranties of any kind. © 2012 Dell Inc . All rights reserved. De ll and its affiliates cannot be responsible fo ...

  • Dell 40G - page 3

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 1 Contents Introduction ................................ ............................................................................. 3 Redundancy ........................................................................................................... 4 Failover roles .............. ...

  • Dell 40G - page 4

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 2 ...

  • Dell 40G - page 5

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 3 Introduction Numerous Dell ™ swi tches include a sta cking feature t hat allows multiple physica l switches to operate as a single logical s witch, p roviding a consolidated int erface for manag ement . T he Dell Force10 MXL 10/40 Gb switch is the latest Dell switch with this featur ...

  • Dell 40G - page 6

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 4 Additional stack mem bers can immedia tely utilize existing co nfiguration informatio n such as routing and switching configurati ons, VLANs, ACLs , port profil es, and security ce rtificates. Redundancy By connecting a ca ble from the last swi tch in a stack back to th e first switch ...

  • Dell 40G - page 7

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 5 Another way to comp letely wipe out a ll configurations and r eturn to factory def aults is to erase the meta-data (NVRAM) a nd delete th e startup configura tion by following th e instructions i n Restoring factory defaults be low. Restoring factor y defaults Usually a standalo ne MX ...

  • Dell 40G - page 8

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 6 no ip address shutdown ! interface TenGigabit Ethernet 0/2 no ip address -- More -- Additional stack -unit lines like t he one below may be fo und in an unstacked MX L if one or more expansion mod ules are present. In order to us e these ports f or stacking the qua d mode will need to ...

  • Dell 40G - page 9

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 7 Port numbering When installed in a Pow erEdge ™ M1000e Enclosure, th e MXL 10/40GbE external swi tch ports are numbered 33 to 56 from the bottom to th e top of the swi tch (ports 1-32 are inte rnal 10G ports): • 40GbE base -mod ule (built -in) ports:  In 2x 40GbE mode of operat ...

  • Dell 40G - page 10

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 8 Combining split 10GbE SFP+ ports into a single 40GbE QSFP+ p ort The MXL 10/40GbE Swit ch supports splittin g each 40G bE port on the base module or a 2 -Port 40GbE QSFP+ expansion mo dule into eight 10GbE SFP+ ports using a break out cable. However, ports must b e combined in to sing ...

  • Dell 40G - page 11

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 9 listed here whe n in port mode. If there is no “sta ck - unit” listing for t he first port number, then the po rts are not split and ar e running at 4 0 GbE. 2. interface fortyGigE 0/33 : interface TenG igabitEthernet 0/41 Each individual port mode is listed furt her down in th e ...

  • Dell 40G - page 12

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 10 Status : on line Next Boot : online Required Type : MXL -10/4 0GbE - 34 -port GE/TE/FG (X L) Current Type : MXL-10/40GbE - 34 -port GE/TE/FG (XL) Master priority : 0 Hardware Rev : X00 Num Ports : 56 Up Time : 1 wk , 3 day, 23 hr , 5 min FTOS Version : 8.3 .16.0E0 Jumbo Capable : y e ...

  • Dell 40G - page 13

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 11 QSFP+ built-in ports a re set to 40 Gb by default whi le expansion mo dule QSFP+ p orts are set to 10 Gb ports by default. To c hange a port from 1 0 Gb mode to 40 Gb mode, use the command FTOS(conf)# no sta ck-unit 0 port p portmode quad Please save and re load for the chang es to t ...

  • Dell 40G - page 14

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 12 Stacking multip le M XL swit ches in a single M1 000e Figure 5. Dell M1000e Blade Chassis B2 C2 A2 B1 C1 A1 4 1 7 5 2 8 6 3 9 CMC2 CMC1 KVM 123456 Gb Gb 2 1 CMC iKVM Gb Gb 2 1 CMC MXL Stack CONSOLE 33-36 37-40 LNK ACT LNK ACT Force10 MXL 10/40GbE 41-48 49-56 CONSOLE 33-36 37-40 LNK A ...

  • Dell 40G - page 15

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 13 The Dell M1000e Se rver Chassi s includes a manag ement console port on the CMC tha t allows a llows management of eac h module from a s ingle serial conn ection to the chassis. Fo r more information , see the Dell Blade Se rver CMC User 's Guide at http://support.dell.co m/supp ...

  • Dell 40G - page 16

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 14 FTOS# show invento ry optional- module Unit Slot Expecte d Inserted N ext Boot Power ------ ----- ------- -------- ------------- ------- -------- ----- ------ 0 0 Q SFP+ QSFP+ AUTO Good 0 1 QSF P+ QSFP+ AUT O Good In this example, sta ck-groups 2 thru 5 correspond to two 40G QSFP+ ex ...

  • Dell 40G - page 17

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 15 Note: When creating s tack ports on an MXL, all ports must be fixed or on the ex pansion module. Mixi ng fixed and expansion mod ule ports in o rder to stack is not supported. Maximum st ack-group per unit A maximum of 4 stack-groups per unit can be configured. In a ring topology, th ...

  • Dell 40G - page 18

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 16 1 Standby o nline MXL - 10/40G bE MXL-10/40GbE 8 .3.16.0E0 56 2 Member on line MXL -10/40GbE MXL -10/40GbE 8 .3.16.0E0 56 3 Member on line MXL -10/40GbE MX L-10/40GbE 8 .3.16.0E0 56 4 Member on line MXL -10/40GbE MXL -10/40GbE 8 .3.16.0E0 56 5 Member on line MXL -10/40GbE MXL -10/40G ...

  • Dell 40G - page 19

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 17 FTOS(conf)# sta ck-unit 1 provision ? MXL-10/40GbE 34-po rt GE/TE/FG (XL) FTOS(conf)# sta ck-unit 1 provision MXL -10/40GbE Certain configurati on changes on th e unit suc h as “fanout” and “stack - grou ps” may require sav ing and reloading the e ntire stack. Refer to the M ...

  • Dell 40G - page 20

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 18 the downloaded image is distributed to all mem ber units of the stack . The inst ructions below wi ll guide the user thro ugh these steps. Note: When upgradi ng a stack of swi tches, allow extra ti me betw een upgrade st eps for files and configurations to be co pied from the Master ...

  • Dell 40G - page 21

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 19 Image upgraded to a ll 4. Verify the new firmware w as copied to all sta ck members. FTOS# show boot syste m stack- unit all Current system ima ge information in th e system: =========== ======= ========== ================= Type Boot Typ e A B ------ ----- ------- -------- ----- ---- ...

  • Dell 40G - page 22

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 20 FTOS# show boot syste m stack- unit all Current system ima ge information in th e system: =========== ======= ========== ================= Type Boot Typ e A B ------ ----- ------- -------- ----- -------- ----- ------- -------- ----- Stack-unit 0 FLASH BOOT 8.3 .15.0 8 -3- 16 -0[boot] ...

  • Dell 40G - page 23

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 21 FTOS(conf)# no sta ck-unit 2 st ack-group 0 FTOS(conf)# no sta ck-unit 2 st ack-group 1 FTOS(conf)# no sta ck-unit 2 st ack-group 2 FTOS(conf)# no sta ck-unit 2 st ack-group 3 : : FTOS(conf)# no sta ck-unit 5 st ack-group 2 FTOS(conf)# no sta ck-unit 5 st ack-group 3 FTOS(conf)# exit ...

  • Dell 40G - page 24

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 22 FTOS# stack-unit 1 renumber 5 % ERROR: stack unit 5 already exis ts. If the new number a ssign ment is already used b y a logi cally provisi oned u nit in the stack, t he be low confirmation message to overwrite is dis played. FTOS# stack-unit 1 renumbe r 5 Stack unit 5 has configura ...

  • Dell 40G - page 25

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 23 Appendix A – Sta cking scenarios When creating s tack ports o n an MXL, all ports must be fixed or on the expansio n module. Mixing fix ed and expansion mod ule ports i n order to stack is not su pported. * When there a re six QSFP+ ports available on the swit ch, a max imum of 4 p ...

  • Dell 40G - page 26

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 24 Appendix B – Port mapping ...

  • Dell 40G - page 27

    S ta c ki n g D e ll Fo r c e1 0 M X L 1 0/ 4 0G S w i tc h es 25 Appendix C - Net work switch vers ions Version information for t he network switc hes used i n creating this docum ent are as f ollows: Network switch Dell Force10 XML Software version 8.3.16.0, E8.3.16.163 , E8.3.16.0E0 ...

Manufacturer Dell Category Switch

Documents that we receive from a manufacturer of a Dell 40G can be divided into several groups. They are, among others:
- Dell technical drawings
- 40G manuals
- Dell product data sheets
- information booklets
- or energy labels Dell 40G
All of them are important, but the most important information from the point of view of use of the device are in the user manual Dell 40G.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Dell 40G, service manual, brief instructions and user manuals Dell 40G. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Dell 40G.

Similar manuals

A complete manual for the device Dell 40G, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Dell 40G by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Dell 40G.

A complete Dell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Dell 40G - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Dell 40G, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Dell 40G, that we can find in the current document
3. Tips how to use the basic functions of the device Dell 40G - which should help us in our first steps of using Dell 40G
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Dell 40G
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Dell 40G in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Dell 40G?

Use the form below

If you did not solve your problem by using a manual Dell 40G, ask a question using the form below. If a user had a similar problem with Dell 40G it is likely that he will want to share the way to solve it.

Copy the text from the picture