  • Home Automation RC-1000 - page 1

    1 1 RC-1000 Th ermostat Installation Ins tructions DESCRIPTION The RC-1000 is a precision digital thermostat designed for 24 VAC he ating and cooling systems. The RC-1000 will support the following systems: ¾ Single Stage Heat/Cool Conventional ¾ Heat Pump (2 Stage Heat / 1 S tage Cool) ¾ Dual Fuel Heat Pump (2 Stage Heat / 1 Stage Coo l) The RC ...

  • Home Automation RC-1000 - page 2

    2 2 Location When replacing an ex isting thermostat, install the RC-1000 in the same location. If the existing location doesn' t meet the following criteria, choose a n ew location to mount the RC-1000. When choosing a location for the thermostat: 1. Ensure that the thermostat is mounted 5 feet above the floor and is at least 2 feet from an ou ...

  • Home Automation RC-1000 - page 3

    3 3 Connect each wire to the terminal st rip(s) on the thermostat base per the wiring diagram for your system application - See Figures 4 - 7. Form the thermostat wiring so that the ca ble lies flat between the termina l strip(s) and the center of the base - See Figure 2 . If a remote s y stem or temperature sensor is bein g used with the thermosta ...

  • Home Automation RC-1000 - page 4

    4 4 TYPICAL WIRING DIAGRAMS CA UTION : Do not short gas valve, fan, heat relay, or cool rela y ...even momentaril y. Do not attempt to hook up to live circuits. An accidental connection to a component on the thermostat circuit board could cause damage to the thermostat. 24VAC "HOT" 24VAC Common 24VAC CONTROL TRANSMFOM ER THERMOSTAT UP 1 3 ...

  • Home Automation RC-1000 - page 5

    5 5 3. When configured as a co nventional thermostat, by default this the rmostat does not turn the fan on with a call for heat. If the furnace requi res the thermostat to turn the fan on with a call for heat, confi gure the “System Mode” to “Fan On W ith Heat” under “System Options” . 4. A conventional thermostat can be configured for ...

  • Home Automation RC-1000 - page 6

    6 6 Single Stage Conventional 24VAC " HOT" Heat 24VAC Com mon* Fan Cool UP 24V AC CONTROL TRANSM FOMER Fan Relay Cool Relay Heat Relay HVAC SYSTEM THERMOSTAT (RC) (C) (Y1) (G) (W1) 1 3 8 6 7 * Common wire is required in “heat only” or “cool only” applications . Also use a common if heat, cool , or fan relay cannot supply 15m A to ...

  • Home Automation RC-1000 - page 7

    7 7 About Heat Pump System s 1) Terminal 5 (O) is energized for coolin g Terminal 6 (B) is energized for heating In most applications, the reversing valve is energiz ed for cooling and should be connected to the "O" terminal. If the heat pump requires the reve rsing valve to be energized fo r heating, connect the rev ersing valve to the & ...

  • Home Automation RC-1000 - page 8

    8 8 Heat Pum p (2 Stage Heat / 1 Stage Cool) 24VAC Common 24VAC "HOT" Auxilirary Heat Compressor Ground Fault Fan Compressor Relay Aux Heat Relay Fan Relay Fault Relay Reversing Valve Energized in Cool Energized in Heat 24VAC CONTROL TRANSM FOMER THERMOSTAT UP HVAC SYSTEM 7 6 8 3 1 (G) (Y1) (B) (C) (RC) 4 5 9 (O) (W2) (L) Figure 7 – Con ...

  • Home Automation RC-1000 - page 9

    9 9 REMOTE SYSTEM WIRING DIAGRAMS This thermostat has been prepro grammed with energ y saving pro gram schedules in accordance with the ENERGY STAR ® program. W hen used with a remote system, HAI recommends that the Program Mode be configured as “None” or “Occup ancy”. This will disable the internal program schedules. HAI HOME CONTROL SYST ...

  • Home Automation RC-1000 - page 10

    1 1 0 0 REMOTE SETBACK SWITCH The thermostat can be connected to a remote switch to toggle the desired heat and cool temperature se ttings between preset setpoints. A signal ca n be sent from the re mote switch location to ch ange the thermostat temperature setting s from the Occupancy Day temperature se ttings to the Occupancy Night temperature se ...

  • Home Automation RC-1000 - page 11

    1 1 1 1 REMOTE TEMPERATURE SENSOR A remote temperature se nsor can be installed to monitor the temperature from a re mote location or can be combined with the onboard temperature sensor for the average temperature of two locations. Run a twisted pair, shielded cable from the RC-10 00 to the remote temperature sensor location. For distances up to 10 ...

  • Home Automation RC-1000 - page 12

    1 1 2 2 SETUP AND CONFI GURATION NOTE: For proper operation of the features of this thermostat, the Ti me and Date must be set. Even w hen connected to an HAI controller which sets the time and day, the Date must be manually set in the ther mostat under the “S ettings” menu. INSTALLATION SETTINGS This section describes the items that the instal ...

  • Home Automation RC-1000 - page 13

    1 1 3 3 System Type *Conventional Dual Fuel Heat Pump 1 Heat Pump *Auto Changeover No Fan With Heat Auto Changeover Fan On With Heat Auto Changeover Fan On With Heat Auto Changeover Fan On With Heat Manual Changeover Fan On With Heat Manual Changeover Fan On With Heat Manual Changeover No Fan With Heat Manual Changeover Fan On With Heat Heat Onl y ...

  • Home Automation RC-1000 - page 14

    1 1 4 4 Cool Mi ni mu m On The number of minutes the thermostat forces the cooling system to remain on before turning off. Raising this number will increase the total time the cooling s y stem is on (saving energ y ), but may allow the temperature to drif t farther from setpoint (decreasing comfort). W hen combined with Cool Minimum Off, cycles per ...

  • Home Automation RC-1000 - page 15

    1 1 5 5 Auxiliary Heat Diffe rential: This determines how far from the setpoint the temperature has to be b efore the auxiliary heat turns on. This is onl y available for heat pump s y stems. Conventional (1 Cool / 1 Heat) Heat Pum p (1 Cool / 2 Heat) Dual Fuel Heat Pump (1 Cool / 2 Heat) EEC *On On / Off EEC *On On / Off EEC Settings Cool Anticipa ...

  • Home Automation RC-1000 - page 16

    1 1 6 6 TROUBLESHOOTIN G TIPS SYMP TOM ACTION TO TAKE 1. Check power to the thermostat Thermostat Dead 2. Check wiring diagrams SYMP TOM ACTION TO TAKE 1. Check for break in W or Y wire 2. Allow minimum off time to pass 3. Check sy stem options for correct setting s 4. If arrow is blinking, wait until startup delay expires 5. Mode is Off (Select He ...

Fabricante Home Automation Categoría Thermostat

Los documentos del dispositivo Home Automation RC-1000 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Home Automation
- manuales de instrucciones RC-1000
- hojas de producto Home Automation
- folletos informativos
- o etiquetas energéticas Home Automation RC-1000
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Home Automation RC-1000.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Home Automation RC-1000, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Home Automation RC-1000. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Home Automation RC-1000.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Home Automation RC-1000, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Home Automation RC-1000. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Home Automation RC-1000.

El manual de instrucciones completo de Home Automation debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Home Automation RC-1000 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Home Automation RC-1000, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Home Automation RC-1000 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Home Automation RC-1000 - que deben facilitarnos los primeros pasos durante el uso de Home Automation RC-1000
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Home Automation RC-1000
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Home Automation RC-1000 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Home Automation RC-1000?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Home Automation RC-1000, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Home Automation RC-1000 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)