Transition Networks CPSMC0800-100 - page 1
T r ansition Netw orks CPSMC08xx-100 8-Slot P ointSystem™ Chassis User’ s Guide revision B CPSMC0800-100 A C -powered CPSMC0810-100 DC -po wered ...
-
Transition Networks CPSMC0800-100 - page 2
2 CPSMC08xx-100 PointSystem™ Chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Compliance Information CISPR22/EN55022 Class A + EN55024 CE Mark FCC Regulations T his equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. T hese limits a ...
-
Transition Networks CPSMC0800-100 - page 3
3 CPSMC08xx-100 PointSystem™ Chassis T able of Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 Unpacking the CPSMC08xx-100 Equipment . . . . . . . . . . . . . . . . .5 2 Slide-in-Modules . ...
-
Transition Networks CPSMC0800-100 - page 4
4 CPSMC08xx-100 PointSystem™ Chassis introduction 1 Intr oduction 1.1 Description T he T ransition Netw orks PointSy stem™ CPSMC08xx-100 is a 19-inch, rac k- mountable chassis for selected T ransition Networks media conv erter slide-in- modules. T he chassis allows the netw ork administrator to connect v arious copper and fiber -optic network m ...
-
Transition Networks CPSMC0800-100 - page 5
5 CPSMC08xx-100 PointSystem™ Chassis introduction 1.2 Unpacking the CPSMC08xx-100 Equipment Use the following list to verify the shipment: Item P art Number 8-Slot chassis with A C power supply CPSMC0800-100 8-Slot chassis with DC po wer supply CPSMC0810-100 PointSy stem™ chassis face plates (5) CPSFP-200 P ower Cord (varies b y country) F ocal ...
-
Transition Networks CPSMC0800-100 - page 6
6 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2 Slide-in-Modules 2.1 Media Converter Slide-in-Modules T ransition Networks media con verter slide-in-modules, installed in slots at the front of the chassis, allo w the network administrator to connect various copper and fiber - optic network media ov er protocols that include Ethernet, F a ...
-
Transition Networks CPSMC0800-100 - page 7
7 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2.1.3 Installing the Media Converter Slide-in-Modules CA UTION: W ear a grounding device and observe electrostatic disc harge precautions when installing the media con verter slide-in-module(s) into the chassis. F ailure to observ e this caution could result in damage to, and subsequent failu ...
-
Transition Networks CPSMC0800-100 - page 8
8 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2.4 Replacing the Media Converter Slide-in-Modules CA UTION: W ear a grounding device and observe electrostatic discharge precautions when replacing media con verter slide-in-module(s). F ailure to observ e this ...
-
Transition Networks CPSMC0800-100 - page 9
9 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2 Management Modules Optional network management is provided b y SNMP software embedded in T ransition Networks P ointSystem ™ management module(s) that can be installed in the CPSMC08xx-100 chassis. T ransitio ...
-
Transition Networks CPSMC0800-100 - page 10
10 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2.2 Installing the Management Modules CA UTION: W ear a grounding device and observe electrostatic disc harge precautions when installing the management module(s) in the CPSMC08xx-100 chassis. F ailure to observ ...
-
Transition Networks CPSMC0800-100 - page 11
11 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2.2.3 Replacing the Management Modules CA UTION: W ear a grounding device and observe electrostatic discharge precautions when replacing media con verter slide-in-module(s). F ailure to obser ve this caution could result in damage to, and subsequent failure of, the management module(s). NO T ...
-
Transition Networks CPSMC0800-100 - page 12
12 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3 P ow ering the CPSMC08xx-100 T he CPSMC08xx-100 chassis can be powered through an AC or DC power supply . An optional auxiliary power supply , with instant fail over protection, is also a vailable. NO TE: The CPSMC08xx-100 c hassis does not hav e an ON/OFF switc h. • P ower up the chassis b ...
-
Transition Networks CPSMC0800-100 - page 13
13 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3.1.2 DC P ow er Supply • T his product is intended to be used in a restricted access location. Proper earthing (grounding) is required to ensure safe operation. Grounding terminals are provided (section 4.1.3) for proper grounding of the device as per customer installation requirements and l ...
-
Transition Networks CPSMC0800-100 - page 14
14 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3.2 Auxiliar y P ow er Supply T he CPSMC08xx-100 chassis can also be supplied with auxiliary power from an external power conv erter , which is connected to the c hassis through the auxiliary power inlet, located on the bac k panel. (Both and A C and a DC external power converter are a vailable ...
-
Transition Networks CPSMC0800-100 - page 15
15 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3.2.2 DC Auxiliar y P ow er Supply • T his product is intended to be used in a restricted access location. Proper earthing (grounding) is required to ensure safe operation. Grounding terminals are provided (section 4.1.3) for proper grounding of the device as per customer installation require ...
-
Transition Networks CPSMC0800-100 - page 16
16 CPSMC08xx-100 PointSystem ™ Chassis chassis 4 CPSMC08xx-100 Chassis 4.1 Installing the CPSMC08xx-100 Chassis T he CPSMC08xx-100 can be installed in a standard 19-inch rac k or on a table, shelf, or other stable surface. CA UTION: Install the chassis so that the air flow ar ound it is not restricted. 4.1.1 T able-T op Installation T he CPSMC08x ...
-
Transition Networks CPSMC0800-100 - page 17
17 CPSMC08xx-100 PointSystem ™ Chassis chassis T o install the CPSMC08xx-100 chassis into a standard 19-inc h rack: 1. Determine the preferred alignment of the c hassis in the rac k. NO TE: Installation bracket mounting screws are provided. Rac k mount screws and clip nuts are NO T provided. 2. Locate six (6) installation brac ket mounting screws ...
-
Transition Networks CPSMC0800-100 - page 18
18 CPSMC08xx-100 PointSystem ™ Chassis chassis 4.1.3 Grounding Lugs T he CPSMC08xx-100 comes equipped with grounding lugs, whic h are provided for a grounding conductor wire terminated with a two-hole, compr ession-type, grounding connector . T he grounding wire -- which must be a copper conductor -- is not included with the chassis and must be p ...
-
Transition Networks CPSMC0800-100 - page 19
19 CPSMC08xx-100 PointSystem ™ Chassis chassis 4.2 Cascade Option T he management module cascade option allows the network administr ator to connect up to eight (8) CPSMC08xx-100 chassis into one manageable stac k, providing a single management source for up to 55 installed media con verter devices. T o create the cascade option, the CPSMM-200 Du ...
-
Transition Networks CPSMC0800-100 - page 20
20 CPSMC08xx-100 PointSystem ™ Chassis chassis T o cascade two or more CPSMC08xx-100 chassis: 1. Locate one (1) T ransition Networks management module cascade cable (with RJ-45 connectors installed at both ends) (P/N 6026) for each set of tw o (2) chassis to be cascaded. NO TE: T ransition Networks management module cascade cables are one (1) met ...
-
Transition Networks CPSMC0800-100 - page 21
21 CPSMC08xx-100 PointSystem ™ Chassis chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 4.3 Connecting the Slide-in-Modules to the Network Once the CPSMC08xx-100 chassis has been installed, the media con verter slide-in- modules ma y be connected to the network. CA UTION: Connect input/output network cables O ...
-
Transition Networks CPSMC0800-100 - page 22
22 CPSMC08xx-100 PointSystem ™ Chassis network mgmt. 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 5 Netw ork Management T he CPSMM100 firmware and the F ocalPoint™ application are described in the Foc alPoint™ 2.0 Management Application and CPSMM100 Firmware user’ s guide (P/N 33293). T his manual is includ ...
-
Transition Networks CPSMC0800-100 - page 23
23 CPSMC08xx-100 PointSystem ™ Chassis network mgmt. 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 DB-9 Serial Port T he DB-9 serial port allows the network administr ator to configure and manage the CPSMC08xx-100 chassis using the SNMP Command-Line Interface (CLI) at an attached terminal or terminal emulator . Us ...
-
Transition Networks CPSMC0800-100 - page 24
24 CPSMC08xx-100 PointSystem ™ Chassis troubleshooting 6 T r oubleshooting 1. Are ANY of the POWER LEDs on an y of the slide-in-modules illuminated; AND/OR are the fans oper ating? YES • T he chassis is recei ving power . Proceed to the next step. NO • Ensure all power supply cables for proper connection. • Ensure the AC receptacle on the w ...
-
Transition Networks CPSMC0800-100 - page 25
25 CPSMC08xx-100 PointSystem ™ Chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 T echnical Specifications F or use with T ransition Networks Model CPSMC08xx-100 or equiv alent. Dimensions 17 x 10.4 x 1.8 inches (432 x 264 x 46 mm) Shipping W eight 8 lbs. (3.6 kg) A C P ow er Supply P ower Input: 100-240 V , 5 ...
-
Transition Networks CPSMC0800-100 - page 26
26 CPSMC08xx-100 PointSystem ™ Chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Cable Specifications Null Modem Cable T he Null Modem Cable is used for connecting a terminal or terminal emulator to the management module’ s DB-9 connector to access the command-line interface. T he table below shows the pin a ...
-
Transition Networks CPSMC0800-100 - page 27
27 CPSMC08xx-100 PointSystem ™ Chassis CO AX Cable Coaxial cable media is used for circuits suc h as DS3, E1 and 10Base-2 Ethernet. T he impedance of the coaxial cable is determined by the interface type, for example: • 75 ohm for DS3. • 50 ohm for 10Base-2 Ethernet. Special attention should be giv en to the grounding requirements of coaxial ...
-
Transition Networks CPSMC0800-100 - page 28
28 CPSMC08xx-100 PointSystem ™ Chassis Contact Us Technical Support T echnical support is a vailable 24 hours a da y . United States: 1-800-260-1312 International: 00-1-952-941-7600 Transition Now Chat liv e via the W eb with a T ransition Networks T echnical Support Specialist. Log onto www .transition.com and click the T ransition No w link. We ...
-
Transition Networks CPSMC0800-100 - page 29
29 CPSMC08xx-100 PointSystem ™ Chassis W arr anty Limited Lifetime Warranty Effectiv e for products shipped May 1, 1999 and after . Every T ransition Networks' labeled product purc hased after May 1, 1999 will be free from defects in material and workmanship for its lifetime. T his warr anty covers the original user only and is not transfera ...
-
Transition Networks CPSMC0800-100 - page 30
30 CPSMC08xx-100 PointSystem ™ Chassis Before making any non-w arranty repair , T ransition Networks requires a $200.00 charge plus actual shipping costs to and from the customer . If the repair is greater than $200.00, an estimate is issued to the customer for authorization of repair . If no authorization is obtained, or the product is deemed no ...
¿Tienes una pregunta acerca de Transition Networks CPSMC0800-100?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Transition Networks CPSMC0800-100, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Transition Networks CPSMC0800-100 probablemente compartirá una forma de solucionarlo.