  • Transition Networks CPSMC0800-100 - page 1

    T r ansition Netw orks CPSMC08xx-100 8-Slot P ointSystem™ Chassis User’ s Guide revision B CPSMC0800-100 A C -powered CPSMC0810-100 DC -po wered ...

  • Transition Networks CPSMC0800-100 - page 2

    2 CPSMC08xx-100 PointSystem™ Chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Compliance Information CISPR22/EN55022 Class A + EN55024 CE Mark FCC Regulations T his equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. T hese limits a ...

  • Transition Networks CPSMC0800-100 - page 3

    3 CPSMC08xx-100 PointSystem™ Chassis T able of Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 Unpacking the CPSMC08xx-100 Equipment . . . . . . . . . . . . . . . . .5 2 Slide-in-Modules . ...

  • Transition Networks CPSMC0800-100 - page 4

    4 CPSMC08xx-100 PointSystem™ Chassis introduction 1 Intr oduction 1.1 Description T he T ransition Netw orks PointSy stem™ CPSMC08xx-100 is a 19-inch, rac k- mountable chassis for selected T ransition Networks media conv erter slide-in- modules. T he chassis allows the netw ork administrator to connect v arious copper and fiber -optic network m ...

  • Transition Networks CPSMC0800-100 - page 5

    5 CPSMC08xx-100 PointSystem™ Chassis introduction 1.2 Unpacking the CPSMC08xx-100 Equipment Use the following list to verify the shipment: Item P art Number 8-Slot chassis with A C power supply CPSMC0800-100 8-Slot chassis with DC po wer supply CPSMC0810-100 PointSy stem™ chassis face plates (5) CPSFP-200 P ower Cord (varies b y country) F ocal ...

  • Transition Networks CPSMC0800-100 - page 6

    6 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2 Slide-in-Modules 2.1 Media Converter Slide-in-Modules T ransition Networks media con verter slide-in-modules, installed in slots at the front of the chassis, allo w the network administrator to connect various copper and fiber - optic network media ov er protocols that include Ethernet, F a ...

  • Transition Networks CPSMC0800-100 - page 7

    7 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2.1.3 Installing the Media Converter Slide-in-Modules CA UTION: W ear a grounding device and observe electrostatic disc harge precautions when installing the media con verter slide-in-module(s) into the chassis. F ailure to observ e this caution could result in damage to, and subsequent failu ...

  • Transition Networks CPSMC0800-100 - page 8

    8 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2.4 Replacing the Media Converter Slide-in-Modules CA UTION: W ear a grounding device and observe electrostatic discharge precautions when replacing media con verter slide-in-module(s). F ailure to observ e this ...

  • Transition Networks CPSMC0800-100 - page 9

    9 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2 Management Modules Optional network management is provided b y SNMP software embedded in T ransition Networks P ointSystem ™ management module(s) that can be installed in the CPSMC08xx-100 chassis. T ransitio ...

  • Transition Networks CPSMC0800-100 - page 10

    10 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2.2 Installing the Management Modules CA UTION: W ear a grounding device and observe electrostatic disc harge precautions when installing the management module(s) in the CPSMC08xx-100 chassis. F ailure to observ ...

  • Transition Networks CPSMC0800-100 - page 11

    11 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2.2.3 Replacing the Management Modules CA UTION: W ear a grounding device and observe electrostatic discharge precautions when replacing media con verter slide-in-module(s). F ailure to obser ve this caution could result in damage to, and subsequent failure of, the management module(s). NO T ...

  • Transition Networks CPSMC0800-100 - page 12

    12 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3 P ow ering the CPSMC08xx-100 T he CPSMC08xx-100 chassis can be powered through an AC or DC power supply . An optional auxiliary power supply , with instant fail over protection, is also a vailable. NO TE: The CPSMC08xx-100 c hassis does not hav e an ON/OFF switc h. • P ower up the chassis b ...

  • Transition Networks CPSMC0800-100 - page 13

    13 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3.1.2 DC P ow er Supply • T his product is intended to be used in a restricted access location. Proper earthing (grounding) is required to ensure safe operation. Grounding terminals are provided (section 4.1.3) for proper grounding of the device as per customer installation requirements and l ...

  • Transition Networks CPSMC0800-100 - page 14

    14 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3.2 Auxiliar y P ow er Supply T he CPSMC08xx-100 chassis can also be supplied with auxiliary power from an external power conv erter , which is connected to the c hassis through the auxiliary power inlet, located on the bac k panel. (Both and A C and a DC external power converter are a vailable ...

  • Transition Networks CPSMC0800-100 - page 15

    15 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3.2.2 DC Auxiliar y P ow er Supply • T his product is intended to be used in a restricted access location. Proper earthing (grounding) is required to ensure safe operation. Grounding terminals are provided (section 4.1.3) for proper grounding of the device as per customer installation require ...

  • Transition Networks CPSMC0800-100 - page 16

    16 CPSMC08xx-100 PointSystem ™ Chassis chassis 4 CPSMC08xx-100 Chassis 4.1 Installing the CPSMC08xx-100 Chassis T he CPSMC08xx-100 can be installed in a standard 19-inch rac k or on a table, shelf, or other stable surface. CA UTION: Install the chassis so that the air flow ar ound it is not restricted. 4.1.1 T able-T op Installation T he CPSMC08x ...

  • Transition Networks CPSMC0800-100 - page 17

    17 CPSMC08xx-100 PointSystem ™ Chassis chassis T o install the CPSMC08xx-100 chassis into a standard 19-inc h rack: 1. Determine the preferred alignment of the c hassis in the rac k. NO TE: Installation bracket mounting screws are provided. Rac k mount screws and clip nuts are NO T provided. 2. Locate six (6) installation brac ket mounting screws ...

  • Transition Networks CPSMC0800-100 - page 18

    18 CPSMC08xx-100 PointSystem ™ Chassis chassis 4.1.3 Grounding Lugs T he CPSMC08xx-100 comes equipped with grounding lugs, whic h are provided for a grounding conductor wire terminated with a two-hole, compr ession-type, grounding connector . T he grounding wire -- which must be a copper conductor -- is not included with the chassis and must be p ...

  • Transition Networks CPSMC0800-100 - page 19

    19 CPSMC08xx-100 PointSystem ™ Chassis chassis 4.2 Cascade Option T he management module cascade option allows the network administr ator to connect up to eight (8) CPSMC08xx-100 chassis into one manageable stac k, providing a single management source for up to 55 installed media con verter devices. T o create the cascade option, the CPSMM-200 Du ...

  • Transition Networks CPSMC0800-100 - page 20

    20 CPSMC08xx-100 PointSystem ™ Chassis chassis T o cascade two or more CPSMC08xx-100 chassis: 1. Locate one (1) T ransition Networks management module cascade cable (with RJ-45 connectors installed at both ends) (P/N 6026) for each set of tw o (2) chassis to be cascaded. NO TE: T ransition Networks management module cascade cables are one (1) met ...

  • Transition Networks CPSMC0800-100 - page 21

    21 CPSMC08xx-100 PointSystem ™ Chassis chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 4.3 Connecting the Slide-in-Modules to the Network Once the CPSMC08xx-100 chassis has been installed, the media con verter slide-in- modules ma y be connected to the network. CA UTION: Connect input/output network cables O ...

  • Transition Networks CPSMC0800-100 - page 22

    22 CPSMC08xx-100 PointSystem ™ Chassis network mgmt. 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 5 Netw ork Management T he CPSMM100 firmware and the F ocalPoint™ application are described in the Foc alPoint™ 2.0 Management Application and CPSMM100 Firmware user’ s guide (P/N 33293). T his manual is includ ...

  • Transition Networks CPSMC0800-100 - page 23

    23 CPSMC08xx-100 PointSystem ™ Chassis network mgmt. 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 DB-9 Serial Port T he DB-9 serial port allows the network administr ator to configure and manage the CPSMC08xx-100 chassis using the SNMP Command-Line Interface (CLI) at an attached terminal or terminal emulator . Us ...

  • Transition Networks CPSMC0800-100 - page 24

    24 CPSMC08xx-100 PointSystem ™ Chassis troubleshooting 6 T r oubleshooting 1. Are ANY of the POWER LEDs on an y of the slide-in-modules illuminated; AND/OR are the fans oper ating? YES • T he chassis is recei ving power . Proceed to the next step. NO • Ensure all power supply cables for proper connection. • Ensure the AC receptacle on the w ...

  • Transition Networks CPSMC0800-100 - page 25

    25 CPSMC08xx-100 PointSystem ™ Chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 T echnical Specifications F or use with T ransition Networks Model CPSMC08xx-100 or equiv alent. Dimensions 17 x 10.4 x 1.8 inches (432 x 264 x 46 mm) Shipping W eight 8 lbs. (3.6 kg) A C P ow er Supply P ower Input: 100-240 V , 5 ...

  • Transition Networks CPSMC0800-100 - page 26

    26 CPSMC08xx-100 PointSystem ™ Chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Cable Specifications Null Modem Cable T he Null Modem Cable is used for connecting a terminal or terminal emulator to the management module’ s DB-9 connector to access the command-line interface. T he table below shows the pin a ...

  • Transition Networks CPSMC0800-100 - page 27

    27 CPSMC08xx-100 PointSystem ™ Chassis CO AX Cable Coaxial cable media is used for circuits suc h as DS3, E1 and 10Base-2 Ethernet. T he impedance of the coaxial cable is determined by the interface type, for example: • 75 ohm for DS3. • 50 ohm for 10Base-2 Ethernet. Special attention should be giv en to the grounding requirements of coaxial ...

  • Transition Networks CPSMC0800-100 - page 28

    28 CPSMC08xx-100 PointSystem ™ Chassis Contact Us Technical Support T echnical support is a vailable 24 hours a da y . United States: 1-800-260-1312 International: 00-1-952-941-7600 Transition Now Chat liv e via the W eb with a T ransition Networks T echnical Support Specialist. Log onto www .transition.com and click the T ransition No w link. We ...

  • Transition Networks CPSMC0800-100 - page 29

    29 CPSMC08xx-100 PointSystem ™ Chassis W arr anty Limited Lifetime Warranty Effectiv e for products shipped May 1, 1999 and after . Every T ransition Networks' labeled product purc hased after May 1, 1999 will be free from defects in material and workmanship for its lifetime. T his warr anty covers the original user only and is not transfera ...

  • Transition Networks CPSMC0800-100 - page 30

    30 CPSMC08xx-100 PointSystem ™ Chassis Before making any non-w arranty repair , T ransition Networks requires a $200.00 charge plus actual shipping costs to and from the customer . If the repair is greater than $200.00, an estimate is issued to the customer for authorization of repair . If no authorization is obtained, or the product is deemed no ...

Manufacturer Transition Networks Category Switch

Documents that we receive from a manufacturer of a Transition Networks CPSMC0800-100 can be divided into several groups. They are, among others:
- Transition Networks technical drawings
- CPSMC0800-100 manuals
- Transition Networks product data sheets
- information booklets
- or energy labels Transition Networks CPSMC0800-100
All of them are important, but the most important information from the point of view of use of the device are in the user manual Transition Networks CPSMC0800-100.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Transition Networks CPSMC0800-100, service manual, brief instructions and user manuals Transition Networks CPSMC0800-100. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Transition Networks CPSMC0800-100.

A complete manual for the device Transition Networks CPSMC0800-100, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Transition Networks CPSMC0800-100 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Transition Networks CPSMC0800-100.

A complete Transition Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Transition Networks CPSMC0800-100 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Transition Networks CPSMC0800-100, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Transition Networks CPSMC0800-100, that we can find in the current document
3. Tips how to use the basic functions of the device Transition Networks CPSMC0800-100 - which should help us in our first steps of using Transition Networks CPSMC0800-100
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Transition Networks CPSMC0800-100
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Transition Networks CPSMC0800-100 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Transition Networks CPSMC0800-100?

Use the form below

If you did not solve your problem by using a manual Transition Networks CPSMC0800-100, ask a question using the form below. If a user had a similar problem with Transition Networks CPSMC0800-100 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)