Manual de instrucciones FMI C42MW

20 de páginas 1.31 mb
Descargar

Pasar a la página of 20

Summary
  • FMI C42MW - page 1

    For more information, visit www .fmiproducts.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers.  ? ...

  • FMI C42MW - page 2

    www .fmiproducts.com 108919-01H 2 SAFETY                     the manufacturer's instructions     ...

  • FMI C42MW - page 3

    www .fmiproducts.com 108919-01H 3 SPECIFICA TIONS 0" TO BOTTOM OUTSIDE AIR (LEFT SIDE ONL Y) TOP SP ACERS 3/4" AIR SP ACE BACK AND SIDES HEARTH EXTENSION 66" X 20" 12" EACH SIDE 1" AIRSP ACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0" TO MA TERIAL NO COMBUSTIBLE MA TERIA L ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OUT ...

  • FMI C42MW - page 4

    www .fmiproducts.com 108919-01H 4 FIREPLACE INST ALLA TION   T o det erm ine safes t and most efci ent locat ion for replace, you must take into consideratio n the following guidelines: 1. Locat ion must allow for prope r clearance s (see Figures 1 and 2). 2. Consider a location where r ...

  • FMI C42MW - page 5

    www .fmiproducts.com 108919-01H 5  A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of replace opening is required to protect combustible oor construction in front of replace. Fabricate a hearth extension using a material which meets t ...

  • FMI C42MW - page 6

    www .fmiproducts.com 108919-01H 6 FIREPLACE INST ALLA TION Continued Figure 4 - Mantel Clearances to Combustible Material Electrical Bushing Electrical Cover Plate Rocker Switch Figure 6 - Fan Switch-Electrical Bushing Electrical Housing Wire Nut (3x) (Not Supplied) Outer Wrapper of Fireplace Electrical Cover Plate and Electrical Bushing Fireplace ...

  • FMI C42MW - page 7

    www .fmiproducts.com 108919-01H 7 Figure 8 - Lineal Gain      42" Fireplace 37 1 / 2 " 12-8DM Pipe Section 10 5 / 8 " 18-8DM Pipe Section 16 5 / 8 " 24-8DM Pipe Section 23 5 / 8 " 36-8DM Pipe Section 34 5 / 8 " 48-8DM ...

  • FMI C42MW - page 8

    www .fmiproducts.com 108919-01H 8 VENTING INST ALLA TION Continued Figure 9 - T ypical Offset Installation Return Elbow Offset Elbow Return Elbow Offset Elbow 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. Return Elbow Offset Elbow Offset Elbow Return Elbow A B C Offset Elbow Ceiling Support Pipe 12S-8DM Return Elbow ...

  • FMI C42MW - page 9

    www .fmiproducts.com 108919-01H 9 Figure 1 1 - Elbow Offset B A Screws Figure 10 - Ceiling Support Pipe 12S-8DM    A B 48"  24" 18" 12" 4 3 / 8 " 16 3 / 8 " ELBOW SET ONL Y 9 3 / 4 " 25 1 / 2 " 1 12 3 / 4 " 30 3 / 4 " 1 ...

  • FMI C42MW - page 10

    www .fmiproducts.com 108919-01H 10 VENTING INST ALLA TION Continued Pitch Slope Opening    Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45.0° 20 3 / 8 " V12F-8DM 4. Remove shingles around opening mea - sured. Cut o ...

  • FMI C42MW - page 11

    www .fmiproducts.com 108919-01H 11 Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 15 - Flashing Installation Figure 16 - Storm Collar Chimney Pipe W aterproof Caulk Storm Collar Flashing Storm Collar Installation (SC1 or SC2) Place storm collar over pipe and slide down unti ...

  • FMI C42MW - page 12

    www .fmiproducts.com 108919-01H 12 10' 2' Min. 10' 3' Min. 2' Min. 3' Min. Level of Flue Gas Outlet Figure 19 - 10 Foot Rule  All ue gas outlet chimney terminations must extend a minimum of 3 feet in height above high est poin t where it passe s throug h roof and must be at least ...

  • FMI C42MW - page 13

    www .fmiproducts.com 108919-01H 13 OPTIONAL GAS LINE INST ALLA TION Figure 21 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel Gas line hook up should be done by your supplier or a qualied service person. Note: Before you proceed, make sur ...

  • FMI C42MW - page 14

    www .fmiproducts.com 108919-01H 14 OPTIONAL GAS LINE INST ALLA TION Continued       has been used for wood burn-      be cleaned of soot, creosote and   ? ...

  • FMI C42MW - page 15

    www .fmiproducts.com 108919-01H 15 Figure 24 - Damper Handle Location OPERA TION AND MAINTENANCE Continued   Damper handle, which opens and closes damper blade, is located inside rebox at cen ter tow ards ba ck wall ( see Fig ure 24) . Pushing handle back into keyway slot will ...

  • FMI C42MW - page 16

    www .fmiproducts.com 108919-01H 16 P ARTS  1 1 27 30 23 22 24 10 14 25 4 17 3 2 1 5 20 28 12 7 15 9 16 13 8 26 6 29 19 18 21 ...

  • FMI C42MW - page 17

    www .fmiproducts.com 108919-01H 17 P ARTS  This list contains replaceable parts used in your replace. When ordering parts, see Replace- ment Parts on page 18 of this manual.  NO.   ? ...

  • FMI C42MW - page 18

    www .fmiproducts.com 108919-01H 18    ACCESSORIES     ? ...

  • FMI C42MW - page 19

    www .fmiproducts.com 108919-01H 19               ? ...

  • FMI C42MW - page 20

    108919-01 Rev . H 09/09 This product is manufactured for Style Crest Inc. under the VEXAR brand name by: FMI PRODUCTS, LLC 2701 S. Harbor Blvd. Santa Ana, CA 92704 www .fmiproducts.com ...

Fabricante FMI Categoría Indoor Fireplace

Los documentos del dispositivo FMI C42MW que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos FMI
- manuales de instrucciones C42MW
- hojas de producto FMI
- folletos informativos
- o etiquetas energéticas FMI C42MW
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones FMI C42MW.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje FMI C42MW, instrucciones de servicio, instrucciones cortas o instrucciones de usuario FMI C42MW. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto FMI C42MW.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo FMI C42MW, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar FMI C42MW. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de FMI C42MW.

El manual de instrucciones completo de FMI debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual FMI C42MW - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice FMI C42MW, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de FMI C42MW que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo FMI C42MW - que deben facilitarnos los primeros pasos durante el uso de FMI C42MW
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con FMI C42MW
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de FMI C42MW en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de FMI C42MW?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con FMI C42MW, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con FMI C42MW probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)