Инструкция обслуживания FMI C42MW

20 страниц 1.31 mb
Скачать

Перейти на страницу of 20

Summary
  • FMI C42MW - page 1

    For more information, visit www .fmiproducts.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers.  ? ...

  • FMI C42MW - page 2

    www .fmiproducts.com 108919-01H 2 SAFETY                     the manufacturer's instructions     ...

  • FMI C42MW - page 3

    www .fmiproducts.com 108919-01H 3 SPECIFICA TIONS 0" TO BOTTOM OUTSIDE AIR (LEFT SIDE ONL Y) TOP SP ACERS 3/4" AIR SP ACE BACK AND SIDES HEARTH EXTENSION 66" X 20" 12" EACH SIDE 1" AIRSP ACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0" TO MA TERIAL NO COMBUSTIBLE MA TERIA L ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OUT ...

  • FMI C42MW - page 4

    www .fmiproducts.com 108919-01H 4 FIREPLACE INST ALLA TION   T o det erm ine safes t and most efci ent locat ion for replace, you must take into consideratio n the following guidelines: 1. Locat ion must allow for prope r clearance s (see Figures 1 and 2). 2. Consider a location where r ...

  • FMI C42MW - page 5

    www .fmiproducts.com 108919-01H 5  A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of replace opening is required to protect combustible oor construction in front of replace. Fabricate a hearth extension using a material which meets t ...

  • FMI C42MW - page 6

    www .fmiproducts.com 108919-01H 6 FIREPLACE INST ALLA TION Continued Figure 4 - Mantel Clearances to Combustible Material Electrical Bushing Electrical Cover Plate Rocker Switch Figure 6 - Fan Switch-Electrical Bushing Electrical Housing Wire Nut (3x) (Not Supplied) Outer Wrapper of Fireplace Electrical Cover Plate and Electrical Bushing Fireplace ...

  • FMI C42MW - page 7

    www .fmiproducts.com 108919-01H 7 Figure 8 - Lineal Gain      42" Fireplace 37 1 / 2 " 12-8DM Pipe Section 10 5 / 8 " 18-8DM Pipe Section 16 5 / 8 " 24-8DM Pipe Section 23 5 / 8 " 36-8DM Pipe Section 34 5 / 8 " 48-8DM ...

  • FMI C42MW - page 8

    www .fmiproducts.com 108919-01H 8 VENTING INST ALLA TION Continued Figure 9 - T ypical Offset Installation Return Elbow Offset Elbow Return Elbow Offset Elbow 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. Return Elbow Offset Elbow Offset Elbow Return Elbow A B C Offset Elbow Ceiling Support Pipe 12S-8DM Return Elbow ...

  • FMI C42MW - page 9

    www .fmiproducts.com 108919-01H 9 Figure 1 1 - Elbow Offset B A Screws Figure 10 - Ceiling Support Pipe 12S-8DM    A B 48"  24" 18" 12" 4 3 / 8 " 16 3 / 8 " ELBOW SET ONL Y 9 3 / 4 " 25 1 / 2 " 1 12 3 / 4 " 30 3 / 4 " 1 ...

  • FMI C42MW - page 10

    www .fmiproducts.com 108919-01H 10 VENTING INST ALLA TION Continued Pitch Slope Opening    Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45.0° 20 3 / 8 " V12F-8DM 4. Remove shingles around opening mea - sured. Cut o ...

  • FMI C42MW - page 11

    www .fmiproducts.com 108919-01H 11 Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 15 - Flashing Installation Figure 16 - Storm Collar Chimney Pipe W aterproof Caulk Storm Collar Flashing Storm Collar Installation (SC1 or SC2) Place storm collar over pipe and slide down unti ...

  • FMI C42MW - page 12

    www .fmiproducts.com 108919-01H 12 10' 2' Min. 10' 3' Min. 2' Min. 3' Min. Level of Flue Gas Outlet Figure 19 - 10 Foot Rule  All ue gas outlet chimney terminations must extend a minimum of 3 feet in height above high est poin t where it passe s throug h roof and must be at least ...

  • FMI C42MW - page 13

    www .fmiproducts.com 108919-01H 13 OPTIONAL GAS LINE INST ALLA TION Figure 21 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel Gas line hook up should be done by your supplier or a qualied service person. Note: Before you proceed, make sur ...

  • FMI C42MW - page 14

    www .fmiproducts.com 108919-01H 14 OPTIONAL GAS LINE INST ALLA TION Continued       has been used for wood burn-      be cleaned of soot, creosote and   ? ...

  • FMI C42MW - page 15

    www .fmiproducts.com 108919-01H 15 Figure 24 - Damper Handle Location OPERA TION AND MAINTENANCE Continued   Damper handle, which opens and closes damper blade, is located inside rebox at cen ter tow ards ba ck wall ( see Fig ure 24) . Pushing handle back into keyway slot will ...

  • FMI C42MW - page 16

    www .fmiproducts.com 108919-01H 16 P ARTS  1 1 27 30 23 22 24 10 14 25 4 17 3 2 1 5 20 28 12 7 15 9 16 13 8 26 6 29 19 18 21 ...

  • FMI C42MW - page 17

    www .fmiproducts.com 108919-01H 17 P ARTS  This list contains replaceable parts used in your replace. When ordering parts, see Replace- ment Parts on page 18 of this manual.  NO.   ? ...

  • FMI C42MW - page 18

    www .fmiproducts.com 108919-01H 18    ACCESSORIES     ? ...

  • FMI C42MW - page 19

    www .fmiproducts.com 108919-01H 19               ? ...

  • FMI C42MW - page 20

    108919-01 Rev . H 09/09 This product is manufactured for Style Crest Inc. under the VEXAR brand name by: FMI PRODUCTS, LLC 2701 S. Harbor Blvd. Santa Ana, CA 92704 www .fmiproducts.com ...

Производитель FMI Категория Indoor Fireplace

Документы, которые мы получаем от производителя устройства FMI C42MW мы можем разделить на несколько групп. Это в частности:
- технические чертежи FMI
- инструкции обслуживания C42MW
- паспорта изделия FMI
- информационные брошюры
- энергетические этикетки FMI C42MW
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания FMI C42MW.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа FMI C42MW, инструкции обслуживания, короткие инструкции или инструкции пользователя FMI C42MW. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия FMI C42MW.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства FMI C42MW, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании FMI C42MW пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей FMI C42MW.

Полная инструкция обслуживания FMI, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией FMI C42MW - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания FMI C42MW, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся FMI C42MW, которое найдем в данном документе
3. Советы по использованию основных функций устройства FMI C42MW - которые должны облегчить нам первые шаги во время использования FMI C42MW
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем FMI C42MW
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра FMI C42MW в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся FMI C42MW?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с FMI C42MW, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с FMI C42MW со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)