Manual de instrucciones Drive Medical Design 14027

20 de páginas 1.59 mb
Descargar

Pasar a la página of 20

Summary
  • Drive Medical Design 14027 - page 1

    Med- Aire 8” Alternating P ressure Mattress R eplacement System With Low Air Loss Item # 14027 ww w . drivemedical. com OPERA TOR’S MANU AL ...

  • Drive Medical Design 14027 - page 2

    2 T ABLE OF CONTENT S IMPORT ANT SAFEGUARDS............................................................................................................ 3 ST A TEMENTS & SYMBOLS..............................................................................................................4 INTRODUCTION.............................................. ...

  • Drive Medical Design 14027 - page 3

    3 IMPORT ANT S AFEGU ARDS When using electrical products, especially when childr en are pr esent, basic safety precautions should always be followed, including the following READ ALL INSTRUCTIONS BEFORE USING DANGER T o r educe the risk of electrocution: • Alwaysunplugthisproductimmediatelyafteruse. • Donotusewh ...

  • Drive Medical Design 14027 - page 4

    4 Note, caution, w ar ning & danger statements NOTE Indicates some tips or some information users should be aware of. CAUTION Indicates correct operatingor maintenance procedure in order to prevent damageto or destructionof theequipmentorotherproperty . W ARNING/DANGER Callsatten ...

  • Drive Medical Design 14027 - page 5

    5 INTRODUCTION This manual should be used for the initial set up of the system and for refer ence purposes. GENERAL The14027seriesisa highqualityandaffor dableair supportsur facesuitablefor mediumandhigh-risk pressur e ulcer tr eatment. It has been specically designed for ...

  • Drive Medical Design 14027 - page 6

    6 P A CKA GE C ONTENT Check inside the package. If any of the following items should be missing or damaged, please contact yourlocaldealerorservicecenterforreplacementimmediately . PUMP Make sure the type of pump is identical to which you pur chased. Functionalitiesvaryfrommodeltomodel. MA TTRESS Cell ...

  • Drive Medical Design 14027 - page 7

    7 PUMP The functions of the pump for the 14027 series are described below . P ower Switc h (1) The switch is at the right side of the pump. T urn ON/OFF the power , the pump will star t/stop operation. Pressure-adjust Knob (2) T urnthesoft/r mknobtosetacomfor tablepr essurelevel. Normal Pressure Indicator (3) ...

  • Drive Medical Design 14027 - page 8

    8 INS T ALLA TION Step 1 Placethemattressatlyonthebedframe. The inationtube should be towar ds the foot endso that it canbe connected to theination nozzles on the pump. Step 2 Y oumayplaceathincottonsheetoverthequiltedmattress? ...

  • Drive Medical Design 14027 - page 9

    9 GROUNDING INS TRUCTIONS Thisproductshouldbegrounded.Inthe eventofan electricalshor tcircuit,gr ounding r educes therisk of electric shock by pr oviding an escape wire for the electric current. This pr oduct is equipped with a cord that contain ...

  • Drive Medical Design 14027 - page 10

    10 OPERA TION Always read the operating instructions befor e use. GENERAL This product is designed to provide maximum comfor t to patients. Make sure that you operate this product in apr oper wayto optimizing itsvalue. Here we provide some generalinformation? ...

  • Drive Medical Design 14027 - page 11

    11 Alwa ys read the operating instructions before use. Please follow instructions below for detailed operating procedur e of each type. Step 1 T urn on the power . The indicator light on the power switch will come on. The pump starts to pump air into the mattress. TheLowPressur eindicator(yelloworred)willcomeonasin? ...

  • Drive Medical Design 14027 - page 12

    12 Alwa ys read the operating instructions before use. CPR FUNCTION When there is an emergency to perform CPR on the patient, pull the CPR strap at the head section of themattresstor eleasetheairquicklyfromthemattr ess. TheCPRstrapislocatedatthefrontright-handsideofthemattr ess ...

  • Drive Medical Design 14027 - page 13

    13 In this section, we describe the procedur es to clean and decontaminate the pump. It is impor tant to follow these procedur es before using the system again. Thecleaningtaskisrequir edatleastonceaweektomaintainpersonalhygiene. PUMP • DONOTimmerseorsoakthepump. • Check ...

  • Drive Medical Design 14027 - page 14

    14 • Laythemattressoutatandupsidedown. • Roll from the foot end towar ds the head end; the foot-end strap can then be stretched around the  rolledmattr esstopreventunr olling. • Donotfold,creaseorstackthemattr ...

  • Drive Medical Design 14027 - page 15

    15 Thepumpdoesn’twork 1. Checkiftheplugisinsertedr mlyintotheoutlet. 2. T urn on the power switch again. • If thepower indicatoris ONand the pumpstill doesn’t work, contact your local dealer immediately . • If the power indicator is O ...

  • Drive Medical Design 14027 - page 16

    16 SPECIFIC A TIONS SYSTEM ITEM SPECIFICA TIONS Classication ClassI;IPX0;AP/APGNO;T ypeBF Applied Part Mattress InputRating AC120V60Hz;12W ,1A FuseRating 250V ,T1A Pressur eRange 30~60mmHg Cycle Time 12 min/50Hz, 10 min/60Hz Dimensions(Pump)? ...

  • Drive Medical Design 14027 - page 17

    17 Y our Drive brand product is warranted to be fr ee of defects in materials and workmanship for 12 months of the original consumer purchaser . This device was built to exacting standards and car efully inspected prior to shipment. This12 monthLimited W ar ...

  • Drive Medical Design 14027 - page 18

    18 NO TES ...

  • Drive Medical Design 14027 - page 19

    19 NO TES ...

  • Drive Medical Design 14027 - page 20

    99SeaviewBoulevard Port Washington, NY 11050 Phone:516-998-4600 Fax:516-998-4601 www .drivemedical.com ...

Fabricante Drive Medical Design Categoría Photo Scanner

Los documentos del dispositivo Drive Medical Design 14027 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Drive Medical Design
- manuales de instrucciones 14027
- hojas de producto Drive Medical Design
- folletos informativos
- o etiquetas energéticas Drive Medical Design 14027
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Drive Medical Design 14027.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Drive Medical Design 14027, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Drive Medical Design 14027. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Drive Medical Design 14027.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Drive Medical Design 14027, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Drive Medical Design 14027. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Drive Medical Design 14027.

El manual de instrucciones completo de Drive Medical Design debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Drive Medical Design 14027 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Drive Medical Design 14027, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Drive Medical Design 14027 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Drive Medical Design 14027 - que deben facilitarnos los primeros pasos durante el uso de Drive Medical Design 14027
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Drive Medical Design 14027
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Drive Medical Design 14027 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Drive Medical Design 14027?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Drive Medical Design 14027, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Drive Medical Design 14027 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)