    5623A Platinum Resistance Thermometer User’ s Guide Rev. 5A1101 Hart Scientific ...

  • Fluke 5623A - page 2

    Rev. 5A1101 Fluke Corporation, Hart Scientific Division • 799 E. Utah Valley Drive • American Fork, UT 84003-9775 • USA Phone: +1.801.763.1600 • Telefax: +1.801.763.1010 • E-mail: support@ hartscientific.com www.hartscientific.com Subject to change without notice. • Copyright © 2004 • Printed in USA ...

  • Fluke 5623A - page 3

    T able of Contents 1 Before Y ou Start ............................1 1.1 Symbols Used ........................................ 1 1.2 Safety Information ..................................... 2 1.2.1 Warnings ................................................... 2 1.2.2 Cautions ................................................... 2 1.3 Hart Scientific ...

  • Fluke 5623A - page 4

    ii Figures Figure 1 PRT Schematic ......................................... 9 ...

  • Fluke 5623A - page 5

    iii T ables T able 1 International Electrical Symbols ................................ 1 T able 2 Specifications ......................................... 7 ...

  • Fluke 5623A - page 6

    1 Before Y ou Start 1.1 Symbols Used T able 1 list s the International Electrical Symbol s. Some or all of these symbols may be used on the instrument or in this manu al. Symbol Description AC (Alternating Current) AC-DC Battery CE Complies with European Union Directives DC Double Insulated Electric Shock Fuse PE Ground Hot Surface (Burn Hazard) Re ...

  • Fluke 5623A - page 7

    Symbol Description Canadian Standards Association OVERVOL T AGE (Installation) CA TEGORY II, Pollution Degree 2 per IEC1010-1 refers to the level of Impulse Withstand Voltage protection provided. Equipment of OVER VOL TAGE CA TE - GORY II is energy-consuming equipment to be supplied from the fixed installation. Exam - ples include household, office ...

  • Fluke 5623A - page 8

    • Keep the shipping container in case it is necessary to ship the PR T . Incor - rect packaging of the PR T for shipment can cause irreparable damage. 1.3 Hart Scientific Authorized Ser vice Centers Please contact one of the follo wing authorized Service Centers to coordinate service on your Hart product: Hart Scientific, Inc. 799 E. Utah V alley ...

  • Fluke 5623A - page 9

    Fluke South East Asia Pte Ltd. Fluke ASEAN Regional Of fice Service Center 83 Clemenceau A venue #15-15/06 Ue Square 239920 SINGAPORE Phone: +65-737-2922 T elefax: +65-737-5155 E-mail: antng@singa.fluke.com When contacting these Service Cente rs for support, please hav e the follo wing information av ailable: • Model Number • Serial Number • ...

  • Fluke 5623A - page 10

    2 Introduction 2.1 General The Platinum Resist ance Thermometers (PR T) model 5623A is designed to be a secondary standard interpolat ing instr ument con verting temperature to resis - tance. The 5623A assembly design all ows for e xposure to very cold tempera - ture (–200°C) and is an i deal reference for veri fication, monitoring or calibratin ...

  • Fluke 5623A - page 11

    3 Specifications and W arranty 3.1 Specifications See T able 2. Temperature Range –200°C to 156°C Entire Assembly Range –200°C to 156°C Accuracy (Includes calibration uncertainty and short-term stability) ±0.05°C (full range) Long-term Drift (°C) <±0.01 at 0°C per year, when used periodically at 200 Hysteresis (°C) <0.01 Tempera ...

  • Fluke 5623A - page 12

    T o exercise this warranty , the purchas er must forward the product after calling or writing an Autho rized Hart Scientific Service Center (see Section 1.3 on page 3) for authorization. The Service Center assumes NO risk for in-transit damage. THE FOREGOING W ARRANTY IS PURCHASER’S SOLE AND EXCLU - SIVE REMED Y AND IS IN LIEU OF ALL O THER W ARR ...

  • Fluke 5623A - page 13

    4 Installation 4.1 Lead Wire Identification The 5623A PR T is equipped with a four-wi re cable (see Figure 1). Four lead wires are used to cancel lead wire resistance. For best results, the readout de - vice should be equipped to handle four -terminal resistors. The lead wires are two dif ferent colors. Lead wire pairs attached to each end of the s ...

  • Fluke 5623A - page 14

    5 PR T Care and Handling Guidelines 5.1 PR T Care CA UTION: READ THIS SECTION BEFORE REMOVING THE PRT FR OM THE SHIPPING BOX OR CASE Care must be taken i n handling the PR T to maintain calibration accuracy . Care should still be used when handling the PR T ev en though the Inconel sheath is durable and provi des good protection for the sensor . Co ...

  • Fluke 5623A - page 15

    • DO NO T scre w a clamp down so tight that it dents the sheath. This can permanently damage the PR T . 12 Hart Scientific 5 PRT Care and Handling Guidelines ...

  • Fluke 5623A - page 16

    6 Operation 6.1 General For best results, be familiar with the operatio n of the heat source and the read-out instrument. Be sure to follo w the manufacturer’ s instructions for the read-out instrument and the heat source. 6.2 Immersion Requirements Stem effect can cause measurement erro rs for an y thermometer not immersed in the fluid at least ...

  • Fluke 5623A - page 17

    7 T roubleshooting 7.1 T roubleshooting In the e vent that the probe appears to function abnormall y , this section may be of use in solving the problem. Se veral possi ble problem conditions are de - scribed along with likely causes and solutions. If a problem arises, please read this section carefully and a ttempt to understand and sol ve the pro ...

Fabricante Fluke Categoría Thermometer

Los documentos del dispositivo Fluke 5623A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Fluke
- manuales de instrucciones 5623A
- hojas de producto Fluke
- folletos informativos
- o etiquetas energéticas Fluke 5623A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Fluke 5623A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Fluke 5623A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Fluke 5623A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Fluke 5623A.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Fluke 5623A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Fluke 5623A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Fluke 5623A.

El manual de instrucciones completo de Fluke debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Fluke 5623A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Fluke 5623A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Fluke 5623A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Fluke 5623A - que deben facilitarnos los primeros pasos durante el uso de Fluke 5623A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Fluke 5623A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Fluke 5623A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Fluke 5623A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Fluke 5623A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Fluke 5623A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)