    F-2200 Series V ortex Flow Meter Installation and Operation Guide For software version CF 4.7 and higher 1500 North Belcher Road • Clearwater , FL 33765 • T el (727) 447-6140 • Fax (727) 442-5699 www .onicon.com • sales@onicon.com 12-15-08 ...

  • Philips F-2200 Series - page 2

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 3 SAFETY INFORMA TION This meter was calibrated at the factory before shipment. T o ensure correct use of the meter , please read this manual thoroughly . Regarding This Manual: • This manual should be passed on to the end user . • Before use, read this manual t ...

  • Philips F-2200 Series - page 3

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 4 F-2200 Series V ortex Flow Meter Installation and Operation Guide Addendum December 12, 2008 CAUTION Insulating the entire neck of the  ow meter will increase heat transfer to the electronics enclosure and may in some cases cause premature failure of the electr ...

  • Philips F-2200 Series - page 4

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 5 T ABLE OF CONTENTS 1.0 INTRODUCTION ............................................................................................................. .7 1.1 Purpose of This Guide ......................................................................................... ...

  • Philips F-2200 Series - page 5

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 6 ...

  • Philips F-2200 Series - page 6

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 7 SECTION 1.0: INTRODUCTION W e, at ONICON INCORPORA TED, would like to thank you for purchasing our F-2200 Series V ortex Flow Meter . As our valued customer , our commitment to you is to provide fast reliable service and assistance, while continuing to offer you n ...

  • Philips F-2200 Series - page 7

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 8 ACCURACY V olumetric  ow ±1% of reading accuracy (±2% for ¾” & smaller sizes) Mass  ow ±1.5% of reading accuracy (±2.5% for ¾” & smaller sizes) OPERA TING TEMPERA TURE RANGE Media temperature 25° to 464° F Ambient temperature 0° to 132° ...

  • Philips F-2200 Series - page 8

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 9 1.4 ADDITIONAL REQUIRED MA TERIALS Installer is responsible for providing suitable  anges and fasteners to connect the meter to the process piping. In addition, most installations will also require one reducer , one expander , pipe supports and a suf cient l ...

  • Philips F-2200 Series - page 9

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 10 SECTION 2.0: UNP ACKING F-2000 series vortex  ow meters are shipped in one package. Additional items, if ordered, will be shipped in separate packaging. All shipments are insured for damage in transit. Carefully inspect each package and notify the freight carr ...

  • Philips F-2200 Series - page 10

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 11 SECTION 3.0: INST ALLA TION INFORMA TION The F-2000 series vortex  ow meter must be installed by a technician quali ed to work with pressurized liquid, steam and/or gas  ow and must conform to all federal, state and local building codes. ONICON will be h ...

  • Philips F-2200 Series - page 11

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 12 The diagrams shown below illustrate the correct meter orientation for vertical and horizontal pipe. Nominal Meter Size (in.) Meter Body Diameter (in.) Maximum Pipe ID Difference (in.) 1” 1.05 0.016 1 1/2” 1.61 0.016 2” 2.07 0.024 3” 3.07 0.024 4” 4.03 0 ...

  • Philips F-2200 Series - page 12

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 13 3.1.3 Straight, Unimpeded Inlet And Outlet Runs D = Meter Size (Nominal diameter in inches) W ith a  ow straightener , the inlet pipe length may be reduced by 50%. For example, with a control valve upstream, the inlet length is 25D instead of 50D. The minimum ...

  • Philips F-2200 Series - page 13

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 14 3.1.5 Locating The Meter In A Pipline That Runs Parallel T o A W all Wherever possible, the distance between the pipe centerline and the wall should be greater than 20”. This will allow for access to the electronics enclosure compartment where wire terminations ...

  • Philips F-2200 Series - page 14

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 15 3.2 MECHANICAL INST ALLA TION 3.2.1 Orient The Display For Convenient V iewing Both the electronics enclosure and the display itself can be rotated to four different orientations to change the viewing angle for the display . If necessary , this should be done bef ...

  • Philips F-2200 Series - page 15

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 16 3.2.1.2 Rotating the display T o rotate the display ,  rst unscrew the cover using the special tool provided for this purpose. Once the cover is removed, the (4) Philips head screws that secure the display are exposed. T o rotate the display , remove these scr ...

  • Philips F-2200 Series - page 16

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 17 3.3.2 T emperature Measurements ONICON F-2000 series vortex meters are supplied with an internal PT 1000 type RTD temperature sensor located within the shedder bar . This sensor provides an accurate temperature measurement at the point where the  ow rate is be ...

  • Philips F-2200 Series - page 17

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 18 SECTION 4.0: ST ART UP AND TROUBLESHOOTING 4.1 ST ART UP When the power is applied to the F-2000 series vortex meter , alphanumeric characters will appear on the display . Initially , the meter will operate in a “TEST” mode where self diagnostic checks are pe ...

  • Philips F-2200 Series - page 18

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 19 4.3 OPERA TING THE DISPLA Y Please read the entire procedure before proceeding. W iring diagrams are located in the Appendix. A worksheet for checking off the following steps and recording measured values is located on the next page. i There are 3 user interface ...

  • Philips F-2200 Series - page 19

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 20 4.4 ERROR HANDLING The meter can detect errors in either the test or the measurement modes. When in the measurement mode, a blinking vertical bar will appear in the top left corner of the display indicating an error has been detected. If the error reporting funct ...

  • Philips F-2200 Series - page 20

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 21 REPORTED PROBLEM POSSIBLE SOLUTIONS A non-zero fl ow indi- cated when no actual fl ow is in the pipe. • Mains interference due to improper Earth ground connection. The protective Earth PE terminal should be properly grounded (see page 17). • Excessive mecha ...

  • Philips F-2200 Series - page 21

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 22 SECTION 5.0: FLOW STRAIGHTENER FOR VORTEX FLOW METERS DESCRIPTION The optional  ow straightener accessory for ONICON F-2000 Series V ortex Flow Meters is a wafer -style  ow conditioner that is designed to be installed between two recessed  anges (provide ...

  • Philips F-2200 Series - page 22

    F-2200 Series V ortex Flow Meter Installation and Operation Guide • Revised 12/08 23 OBSTRUCTION SEE TABLE 1 UPSTREAM DIMENSION B 2 DIAMETERS 5 DIAMETERS ONICON F-2000 SERIES STEAM METER, NOTE 1 300# ANSI FLANGE ECCENTRIC REDUCER, NOTE 2 FLOW STRAIGHTENER, NOTE 3 (600# ANSI FLANGE OPTNL) MINIMUM UPSTREAM PIPE RUN MINIMUM DOWNSTREAM PIPE RUN REQUI ...

Fabricante Philips Categoría Automobile Parts

Los documentos del dispositivo Philips F-2200 Series que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Philips
- manuales de instrucciones F-2200 Series
- hojas de producto Philips
- folletos informativos
- o etiquetas energéticas Philips F-2200 Series
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Philips F-2200 Series.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Philips F-2200 Series, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Philips F-2200 Series. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Philips F-2200 Series.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Philips F-2200 Series, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Philips F-2200 Series. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Philips F-2200 Series.

El manual de instrucciones completo de Philips debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Philips F-2200 Series - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Philips F-2200 Series, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Philips F-2200 Series que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Philips F-2200 Series - que deben facilitarnos los primeros pasos durante el uso de Philips F-2200 Series
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Philips F-2200 Series
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Philips F-2200 Series en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Philips F-2200 Series?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Philips F-2200 Series, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Philips F-2200 Series probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)