Manual de instrucciones Rheem RSNA-B Series

40 de páginas 2.27 mb
Descargar

Pasar a la página of 40

Summary
  • Rheem RSNA-B Series - page 1

    FORM NO. S1 1-933 REV . 2 Supersedes Form No. S1 1-933 Rev . 1 RSNA-B SUPER HIGH EFFICIENCY 1 3-SEER SERIES NOMINAL SIZES 2-5 TONS [7 .0-1 7 .6 kW] P ACKAGE A IR C ONDITIONERS ...

  • Rheem RSNA-B Series - page 2

    2 T ABLE OF CONTENTS Unit Features & Benefits ..............................................................................3-4 Model Identification Options ..........................................................................5 - 6 General Data RSNA-B Series .................................................................................. ...

  • Rheem RSNA-B Series - page 3

    3 UNIT FEA TURES & BENEFITS—RSNA-B These qualit y feature s are inc luded in the Rhe em P acka ge Air Conditioner 5 ...

  • Rheem RSNA-B Series - page 4

    4 UNIT FEA TURES & BENEFITS—RSNA-B SERIES 1. All models feature Copeland ® Scroll ® compressors for maxi- mum efficiency and quiet operation. 2. Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes. 3. One-piece top with a drip lip to help keep water off of the unit sides. 4. Supply and return ...

  • Rheem RSNA-B Series - page 5

    R S N A — B 036 J K 010 X X Factory Installed Options (See Next Page) Heating Capacity (Factory Installed) 000 = No Resistance Heat 005 = 05 KW Resistance Heat (018-030) 010 = 10 KW Resistance Heat (024-048) 015 = 15 KW Resistance Heat (036-048) Drive Package K = Direct Drive Electrical Designation J = 208-230V—1PH—60 Hz C = 208-230V—3PH— ...

  • Rheem RSNA-B Series - page 6

    6 OPTIONS—RSNA-B SERIES Option Code Side Flow AA No Option AK x F A CT OR Y INST ALLED OPTION CODES Example: RSNA-B036JK000 XX (where XX is factory installed option) Example: No Options RSNA-B036JK000 Example: Options with Sideflow RSNA-B036JK000AK Note: Factory installed economizer is not available on these models. Instructions f or F actory Ins ...

  • Rheem RSNA-B Series - page 7

    7 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B024JK B030JK B036CK B036JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 24,800 [7.27] 31,200 [9.14] 37,400 [10.96] 37,400 [10.96] EER/SEER 2 11.8/13 11.1/13 11.7/13 11.7/13 Nominal CFM/ARI Rated CFM [L/s] 800/800 [378/378] 1000/1000 [472/472] 1200/1200 [566/566] 1200/1200 [566/566] ARI ...

  • Rheem RSNA-B Series - page 8

    8 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B042CK B042JK B048CK B048JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 42,500 [12.45] 42,500 [12.45] 50,500 [14.8] 50,500 [14.8] EER/SEER 2 11.5/13 11.5/13 11.6/13 11.6/13 Nominal CFM/ARI Rated CFM [L/s] 1400/1350 [661/637] 1400/1350 [661/637] 1600/1600 [755/755] 1600/1600 [755/755] AR ...

  • Rheem RSNA-B Series - page 9

    9 GENERAL DA T A—RSNA-B SERIES Model RSNA-B Series B060CK B060JK Cooling Performance 1 Gross Cooling Capacity Btu [kW] 60,000 [17.58] 60,000 [17.58] EER/SEER 2 11.1/13 11.1/13 Nominal CFM/ARI Rated CFM [L/s] 2000/1850 [897/873] 2000/1850 [897/873] ARI Net Cooling Capacity Btu [kW] 58,000 [16.99] 58,000 [16.99] Net Sensible Capacity Btu [kW] 40,56 ...

  • Rheem RSNA-B Series - page 10

    10 GENERAL DA T A—RSNA-B SERIES NO TES: 1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to  20% of nominal cfm. Units are certified ...

  • Rheem RSNA-B Series - page 11

    11 SYSTEMS PERFORMANCE—RSNA-B SERIES GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B024 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 880 [415] 800 [378] 680 [321] 880 [415] 800 [378] 680 [321] 880 [415] 800 [378] 680 [321] DR ➀ .21 .20 .18 .21 .20 .18 .21 .20 .18 O U T D O O R D R Y B U ...

  • Rheem RSNA-B Series - page 12

    12 SYSTEMS PERFORMANCE—RSNA-B SERIES GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B036 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 1320 [623] 1200 [566] 1020 [481] 1320 [623] 1200 [566] 1020 [481] 1320 [623] 1200 [566] 1020 [481] DR ➀ .21 .20 .17 .21 .20 .17 .21 .20 .17 O U T D O O R ...

  • Rheem RSNA-B Series - page 13

    GR OSS SYSTEMS PERFORMANCE D A T A—RSNA-B048 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 1760 [831] 1600 [755] 1360 [642] 1760 [831] 1600 [755] 1360 [642] 1760 [831] 1600 [755] 1360 [642] DR ➀ .20 .19 .17 .20 .19 .17 .20 .19 .17 O U T D O O R D R Y B U L B T E M P E R A T U R E °F ...

  • Rheem RSNA-B Series - page 14

    INDOOR AIRFLO W PERFORMANCE—208 V OL TS External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—208 Volts Side Discharge—Wet Coil Nominal Cooling Capacity T ons [kW] Motor Speed from Factory Motor Speed RPM 730 775 820 865 905 940 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17] 975 RPM 695 785 870 ...

  • Rheem RSNA-B Series - page 15

    15 AIRFLOW PERFORMANCE—RSNA-B SERIES INDOOR AIRFLO W PERFORMANCE—230 V OL TS External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—230 Volts Side Discharge—Wet Coil Blower Size/ Motor HP [W] & # of Speeds Nominal Cooling Capacity T ons [kW] Motor Speed from Factory Motor Speed 10x9 1 HP ECM (Constant CFM) RPM 76 ...

  • Rheem RSNA-B Series - page 16

    ELECTRICAL DA T A – RSNA-B SERIES Minimum Circuit Ampacity Minimum Overcurrent Protection Device Size 16/16 20/20 Maximum Overcurrent Protection Device Size 25/25 Compressor Motor No. 1 Volts 208/230 Phase 1 HP 2 1/6 RPM 3450 Amps (RLA) 10.4/10.4 Amps (LRA) Unit Information Unit Operating Voltage Range 54/54 187-253 Condenser Motor No. 1 Volts 20 ...

  • Rheem RSNA-B Series - page 17

    B024JK No Heat — — 16/16 20/25 20/25 A10J 24.57/32.76 34.6/40.0 45/52 45/45 60/60 A05J 12.28/16.38 17.3/20.0 24/27 25/25 30/30 44/50 45/50 — — — — — 16/16 20/25 20/25 22/25 25/25 — — — RXQJ- Heater Kit Nominal kW Heater KBTU/Hr @ 208/240 V Heater Amp. @ 208/240 V Unit Min. Ckt. Ampacity @ 208/240 V Over Current Protective Device ...

  • Rheem RSNA-B Series - page 18

    30% 2% 21% 2% 29% 2% 20% 2% CORNER WEIGHTS % OF TO T AL UNIT WEIGHT THERMOST A T WIRING ENTRANCE ELECTRICAL POWER ENTRANCE BLOWER/ EV APORA T OR ACCESS P ANEL SIDE SUPPL Y DUCT OPENING SIDE RETURN DUCT OPENING TOP COVER UNIT DIMENSIONS P A CKA GE AIR CONDITIONERS OUTDOOR F AN GRILLE AND COMPRESSOR ACCESS CONTROL ACCESS P ANEL LIQUID PRESSURE SERVIC ...

  • Rheem RSNA-B Series - page 19

    52 7 / 16 " [1332 mm] FIL TER ACCESS P ANEL (FOR UNIT MOUNTED FIL TER ACCESSOR Y BLOWER/ EV APORA TOR ACCESS P ANEL OUTDOOR COIL PROTECTIVE GRILLE 25 5 / 16 " [643 mm] 10 3 / 16 " [259 mm] 4 3 / 4 " [121 mm] 5 1 / 16 " [129 mm] 1 1 / 8 " [28.6 mm] THERMOST A T WIRE ENTRANCE ELECTRICAL POWER ENTRANCE SIDE VIEW SIDE VIEW ...

  • Rheem RSNA-B Series - page 20

    20 TYPICAL INST ALLA TIONS ...

  • Rheem RSNA-B Series - page 21

    COMMON SUPPL Y/RETURN CONCENTRIC AIR DIFFUSER SUPPL Y AIR/PERFORMANCE NO TE: The location of the combination supply and return diffuser should not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM [472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level for units with CFM greater than 1000 [472 L/s]. If the diffu ...

  • Rheem RSNA-B Series - page 22

    DUCT AD APTERS RECT ANGULAR T O R OUND TRANSITIONS (DO WNFLO W) RXMC-CA03 RXMC-CA02 [ ] Designates Metric Con versions 22 ACCESSORIES ...

  • Rheem RSNA-B Series - page 23

    [ ] Designates Metric Con versions RXRE-CAA30 (3 P osition) Provided with enthalpy control, and mixed air sensor . Settings include fully open, fully closed and adjustable mid point. RXRD-CAM1 0 (Fully Modulating) Provided with enthalpy control, mixed air sensor and minimum position poten- tiometer for proportioning (modulating) the amount of fresh ...

  • Rheem RSNA-B Series - page 24

    CFM [L/s] RSNA-B 680 [321] RSNA-B 850 [401] RSNA-B 1020 [481] RSNA-B 1190 [562] RSNA-B 1275 [602] 1500 [708] 1400 [661] 1200 [566] 1000 [472] 800 [378] 1650 [779] 1540 [727] 1320 [623] 1100 [519] 880 [415] Minimum Airflow Model No. Nominal Airflow Maximum Airflow 510 [241] RSNA-B 600 [283] 660 [311] Airflow Pressure Drop, Inches W .C. [kPa] 1" ...

  • Rheem RSNA-B Series - page 25

    DUCT AD APTER SIDEFLO W SQU ARE T O R OUND TRANSITION RXMC-B A01 Adapts the side rectangular supply and return openings to 14" [356 mm] diameter round openings. Adapters provided with same finish as unit and also provided with thermal insulation. 25 ACCESSORIES ...

  • Rheem RSNA-B Series - page 26

    RXSG-AAA 14 (1 4" [356 mm] High) RXSG-AAA08 (8" [203 mm] High) R OOFCURB (Full P erimeter) RXSG-AAA08, RXSG-AAA 1 4 and RXSG-AAA24 for RSNA-B Series Hinged corners make for fast, easy set-up. NO T f or use with RQKA/RQLA/RQMA P acka ge Heat Pumps. [ ] Designates Metric Con versions 26 ACCESSORIES ...

  • Rheem RSNA-B Series - page 27

    R OOFCURB (Full P erimeter) (Cont.) [ ] Designates Metric Con versions RXSG-AAA24 (24" [610 mm] High) 27 ACCESSORIES ...

  • Rheem RSNA-B Series - page 28

    [ ] Designates Metric Con versions P A CKA GE AIR CONDITIONERS & GAS/ELECTRIC P A CKA GE UNITS R OOFCURB INST ALLA TION (Full P erimeter) OLD MODEL OLD CURB MODEL NEW MODEL TO OLD MODEL ROOFCURB AD APTER NEW MODEL P ACKA GE ONL Y 1 CABINET SIZE — ALL MODELS RSNA-B SMALL CABINET 20 SERIES RXPX-BACCA20 RXRX-BACDB20 RXPX-BACCA21 RXRX-BACDB21 RXP ...

  • Rheem RSNA-B Series - page 29

    LIFT KIT—MODEL NO . RXML-A01 The lift kit is intended for temporary installation while the unit is being lifted into position. Kit includes 4 lift brackets. 29 ACCESSORIES ...

  • Rheem RSNA-B Series - page 30

    W ARNING ONL Y ELECTRIC HEA TER KITS SUPPLIED BY THIS MANUF ACTURER AS DESCRIBED IN THIS PUBLICA TION HA VE BEEN DESIGNED, TESTED, AND EV ALU A TED BY A NA TIONALL Y RECOGNIZED SAFETY TESTING A GENCY FOR USE WITH THIS UNIT . USE OF ANY O THER MANUF A CTURED ELECTRIC HEA TERS INST ALLED WITHIN THIS UNIT MA Y CAUSE HAZARDOUS CONDITIONS RESUL TING IN ...

  • Rheem RSNA-B Series - page 31

    31 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 32

    32 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 33

    33 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 34

    34 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 35

    35 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 36

    36 WIRING SCHEMA TICS—RSNA-B SERIES ...

  • Rheem RSNA-B Series - page 37

    37 NOTES ...

  • Rheem RSNA-B Series - page 38

    38 NOTES ...

  • Rheem RSNA-B Series - page 39

    39 NOTES ...

  • Rheem RSNA-B Series - page 40

    Before pr oceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Pro vincial, and Local codes, regulations, and practices. RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 “In keeping with its policy of contin uous progress and produ ...

Fabricante Rheem Categoría Air Conditioner

Los documentos del dispositivo Rheem RSNA-B Series que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Rheem
- manuales de instrucciones RSNA-B Series
- hojas de producto Rheem
- folletos informativos
- o etiquetas energéticas Rheem RSNA-B Series
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Rheem RSNA-B Series.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Rheem RSNA-B Series, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Rheem RSNA-B Series. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Rheem RSNA-B Series.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Rheem RSNA-B Series, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Rheem RSNA-B Series. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Rheem RSNA-B Series.

El manual de instrucciones completo de Rheem debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Rheem RSNA-B Series - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Rheem RSNA-B Series, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Rheem RSNA-B Series que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Rheem RSNA-B Series - que deben facilitarnos los primeros pasos durante el uso de Rheem RSNA-B Series
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Rheem RSNA-B Series
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Rheem RSNA-B Series en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Rheem RSNA-B Series?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Rheem RSNA-B Series, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Rheem RSNA-B Series probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)