Manual de instrucciones Agilent Technologies 3499A/B/C

20 de páginas 0.71 mb
Descargar

Pasar a la página of 20

Summary
  • Agilent Technologies 3499A/B/C - page 1

    How your 3499A/B/C T est System Benefits From Upgrading to the New 34980A Switch/Measure/Control System Application Note This application not e will describe differences and advant ages of t he new 34980A as compared to the 3499A/B/C. The 34980A Switch/Measure System masters switching, measurement, and control features by offering a superior select ...

  • Agilent Technologies 3499A/B/C - page 2

    2 List of 34980A Measurement Capabilities • T emperature measured with Thermocouples, RTDs and Thermistors • DC and AC volts • 2- and 4-wire Resistance • Frequency and Period • DC and AC current • 4 alarms for High/Low or both limits for each channel • Digital I/O • Analog outputs (DAC) The 34980A mainframe also includes f our 2-wir ...

  • Agilent Technologies 3499A/B/C - page 3

    3 Modules The 34980A implements a superior selection of switch topologies. The 34980A swit ch topologies are similar t o 3499A/B/C switch modules and include multiplex ers, matrixes, high-po w er , general purpose, and RF/micro wav e switches. Ho wev er , the 34980A modules hav e utilized the new est swit ch technology which enables a higher densit ...

  • Agilent Technologies 3499A/B/C - page 4

    4 Module T ype 34980A 3499A/B/C Multiplexer 34921A 40 Ch armature 300V 1A N2260A 40 Ch armature 200V 1A 34922A 70 Ch armature 300V 1A N2266A 40 Ch reed 200V .5A 34923A 40 Ch reed 200V .5A N2270A 10 Ch 1000V 1A 34924A 70 Ch reed 80V .5 44470A 10 Ch armature 250V 2A 34925A 40 Ch FET +/-80V .5A 44470D 20 Ch armature 250V 2A General Purpose 34937A 28 C ...

  • Agilent Technologies 3499A/B/C - page 5

    5 User Interface The 34980A of fers the most modern instr ument I/O options for inter facing a controller PC wit h the switch system: GPIB, USB and L AN. All three Input/Output inter face connections come standard with the 34980A mainframe. If you choose t o modify or upgrade your test system I/O, the 34980A is system ready. Y ou can also easily co ...

  • Agilent Technologies 3499A/B/C - page 6

    6 W eb Page Interface The 34980A comes wit h a built-in detailed instr ument w eb page that allo ws you t o remot ely connect and communicate with the mainframe and installed modules. Y ou establish a L AN connection, eit her directly between t he 34980A and PC, or from the 34980A to an existing Local Area Netw ork. The instrument W eb page resides ...

  • Agilent Technologies 3499A/B/C - page 7

    7 T able 4. Command comparisons 34980A 3499A/B/C Close channel 10 on the module in slot 3 ROUT e:CLOS (@3010) [ROUT e:]CLOS (@310) Scan channels 0 through 40 on the module in slot 1 ROUT e:SCAN (@1001:1040) [ROUT e:]SCAN (@100:140) and channel(s) rat her than only three digits as the 3499A/B/C uses. Also, for t he 3499A/B/C t he [ROUT e] in the com ...

  • Agilent Technologies 3499A/B/C - page 8

    8 Scan Feature The scan feature is a sequence of alternating swit ch closures and measurements. This feature is pro vided by bot h the 34980A and a 3499A/B/C combined wit h a DMM or ot her measurement instrument. The 34980A increases the measurement scan abilities and offers more than twice the number of scanned channels within one scan list compar ...

  • Agilent Technologies 3499A/B/C - page 9

    9 Monitor Feature The 34980A monit or feature allo ws you t o monit or readings acquired by the switch/measure system. Y ou can also monitor readings acquired wit h t he 34980A internal DMM. T o monitor a measurement from the front panel, simply select the channel and press eit her t he Measure [DMM] or [Channel] button to see a continually updated ...

  • Agilent Technologies 3499A/B/C - page 10

    10 Switch and Measurement Connections Most often, t est syst ems must be f lexible enough to be easily mov ed to a new location or modified for different devices under test. Having a remo vable wiring ter minal block or a pre-wired cable is optimal in t hese situations. The module’s terminal and/or cable can sim ply be remov ed and replaced with ...

  • Agilent Technologies 3499A/B/C - page 11

    11 Summary Although the 3499A/B/C Switch/Control system has been a great addition to many test systems, the new 34980A now offers an even better module selection plus measurement capability , standard PC connections f or communication, and is easy to connect to modules. The wide of fering of plug-in modules f or t he 34980A enables you to select a ...

  • Agilent Technologies 3499A/B/C - page 12

    12 Appendix A – Command Reference/Comparison 34980A Commands ABORt CALCulate :A VERage:AVERage? :A VERage:CLEar :A VERage:COUNt? :A VERage: MAXimum? :A VERage:MAXimum:TIME? :A VERage:MINimum? :A VERage:MINimum:TIME? :A VERage:PTPeak? :LIMit:LOW er :LIMit:LOW er? :LIMit:LOW er:ST A T e :LIMit:LOW er:ST A T e? :LIMit:UPPer :LIMit:UPPer? :LIMit:UPPe ...

  • Agilent Technologies 3499A/B/C - page 13

    13 :CURRent:AC :CURRent[:DC] :DIGital:ST A T e :DIGital:WIDTh :FREQuency :FRESistance :PERiod :RESistance :TEMPerature :TOT alize [:VOL T age]:AC [:VOL T age][:DC] CONFigure? DA T A :LAST? :POINts:EVENt:THReshold :POINts:EVENt:THReshold? :POINts? :REMove? DIAGnostic :DMM:CYCLes:CLEar :DMM:CYCles? :RELay CYCles:CLEar :RELay:CYCLes? DISPlay [:ST A T ...

  • Agilent Technologies 3499A/B/C - page 14

    14 :CURRent:AC? :CURRent[:DC]? :DIGital[:<width>]? :DIGital[:BYTE]:BIT? :FREQuency? FRESistance? :PERiod? :RESistance? :TEMPerature? :TOT alize? [:VOL T age]:AC? [:VOL T age][:DC]? MEMory :ST A T e:CA T alog? :ST A T e:DELete :ST A T e:NAME :ST A T e:NAME? :ST A T e:RECall:AUTO :ST A T e:RECall:AUTO? :ST A T e:RECall:SELect :ST A T e:RECall:S ...

  • Agilent Technologies 3499A/B/C - page 15

    15 :SCAN :SCAN:ADD :SCAN:REMove :SCAN:SIZE? SAMPle :COUNt :COUNt? SENSe :CURRent:AC :BANDwidth :BANDwidth? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :CURRent[:DC] :APERture:ENABled? :APERture :NPLC :NPLC? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :RESolution :RESolution? :ZERO:AUTO :DIGital:DA T A[:<width>]? :DIGital:DA T A[BYTE]:BIT? :FREQuency ...

  • Agilent Technologies 3499A/B/C - page 16

    16 :RANGe:AUTO? :RESolution :RESolution? :ZERO:AUTO :FUNCtion :FUNCtion? :PERiod:APERture :PERiod:VOL T age:RANGe :VOL T age:RANGe? :VOL T age:RANGe:AUTO :VOL T age:RANGe:AUTO? :PERiod:ZERO:AUTO :RESistance:APERture :APERture? :ALPERture:ENABled? :NPLC :NPLC? :OCOMpensated :OCOMpensated? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :RESolution :RESoluti ...

  • Agilent Technologies 3499A/B/C - page 17

    17 [:DC]:NPLC? [:DC]:RANGe [:DC]:RANGe? [:DC]:RANGe:AUTO [:DC]:RANGe:AUTO? [:DC]:RESolution [:DC]RESolution [:DC]:ZERO:AUTO [:DC]:ZERO:AUTO? SOURce :CURRent[:LEV el] :CURRent[:LEV el]? :DIGital:DA T A[:<width>] :DIGital:DA T A[BYTE]:BIT :DIGital:ST A T e? :FUNCtion:CLOCk:EXT ernal:DIVisor :CLOCk[INT ernal]:PERiod :CLOCk:SOURce :CURRent:GAIN : ...

  • Agilent Technologies 3499A/B/C - page 18

    18 :ALARm:ENABle? :ALARm[:EVENt]? :MODule:ENABle :MODule:EVENt? :MODule:SLOT[n]:CONDition? :MODule:SLOT[n]:ENABle :MODule:SLOT[n][:EVENt]? :OPERation:CONDition? :OPERation:ENABle :OPERation:ENABle? :OPERation[:EVENt]? :PRESet :QUEStionable:CONDition? :QUEStionable:ENABle :QUEStionable:ENABle? :QUEStionable[:EVENt]? SYST em :ABUS:INT erlock:SIMulate ...

  • Agilent Technologies 3499A/B/C - page 19

    19 :TIME? :TIME:SCAN? :VERSion? TRACe:CA T alog? [:DA T A] [:DA T A]:DAC [:DA T A]:FUNCtion :DELete:ALL :DELete[:NAME] :FREE? :POINts? TRIGger :COUnt :COUNt? :DELay :DELay? :DELay:AUTO :DELay:AUTO? :SOURce :SOURce? :TIMer :TIMer? UNIT :TEMPerature :TEMPerature? IEEE-488.2 Common Commands *CLS *ESE *ESE? *ESR? *IDN? *OPC *OPC? *PSC *PSC? *RCL *RST * ...

  • Agilent Technologies 3499A/B/C - page 20

    Agilent T echnologies ’ T est and Measurement Support, Services, and Assistance Agilent T echnologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can ...

Fabricante Agilent Technologies Categoría Switch

Los documentos del dispositivo Agilent Technologies 3499A/B/C que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Agilent Technologies
- manuales de instrucciones 3499A/B/C
- hojas de producto Agilent Technologies
- folletos informativos
- o etiquetas energéticas Agilent Technologies 3499A/B/C
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Agilent Technologies 3499A/B/C.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Agilent Technologies 3499A/B/C, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Agilent Technologies 3499A/B/C. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Agilent Technologies 3499A/B/C.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Agilent Technologies 3499A/B/C, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Agilent Technologies 3499A/B/C. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Agilent Technologies 3499A/B/C.

El manual de instrucciones completo de Agilent Technologies debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Agilent Technologies 3499A/B/C - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Agilent Technologies 3499A/B/C, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Agilent Technologies 3499A/B/C que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Agilent Technologies 3499A/B/C - que deben facilitarnos los primeros pasos durante el uso de Agilent Technologies 3499A/B/C
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Agilent Technologies 3499A/B/C
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Agilent Technologies 3499A/B/C en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Agilent Technologies 3499A/B/C?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Agilent Technologies 3499A/B/C, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Agilent Technologies 3499A/B/C probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)