Agilent Technologies 3499A/B/Cの取扱説明書

20ページ 0.71 mb
ダウンロード

ページに移動 of 20

Summary
  • Agilent Technologies 3499A/B/C - page 1

    How your 3499A/B/C T est System Benefits From Upgrading to the New 34980A Switch/Measure/Control System Application Note This application not e will describe differences and advant ages of t he new 34980A as compared to the 3499A/B/C. The 34980A Switch/Measure System masters switching, measurement, and control features by offering a superior select ...

  • Agilent Technologies 3499A/B/C - page 2

    2 List of 34980A Measurement Capabilities • T emperature measured with Thermocouples, RTDs and Thermistors • DC and AC volts • 2- and 4-wire Resistance • Frequency and Period • DC and AC current • 4 alarms for High/Low or both limits for each channel • Digital I/O • Analog outputs (DAC) The 34980A mainframe also includes f our 2-wir ...

  • Agilent Technologies 3499A/B/C - page 3

    3 Modules The 34980A implements a superior selection of switch topologies. The 34980A swit ch topologies are similar t o 3499A/B/C switch modules and include multiplex ers, matrixes, high-po w er , general purpose, and RF/micro wav e switches. Ho wev er , the 34980A modules hav e utilized the new est swit ch technology which enables a higher densit ...

  • Agilent Technologies 3499A/B/C - page 4

    4 Module T ype 34980A 3499A/B/C Multiplexer 34921A 40 Ch armature 300V 1A N2260A 40 Ch armature 200V 1A 34922A 70 Ch armature 300V 1A N2266A 40 Ch reed 200V .5A 34923A 40 Ch reed 200V .5A N2270A 10 Ch 1000V 1A 34924A 70 Ch reed 80V .5 44470A 10 Ch armature 250V 2A 34925A 40 Ch FET +/-80V .5A 44470D 20 Ch armature 250V 2A General Purpose 34937A 28 C ...

  • Agilent Technologies 3499A/B/C - page 5

    5 User Interface The 34980A of fers the most modern instr ument I/O options for inter facing a controller PC wit h the switch system: GPIB, USB and L AN. All three Input/Output inter face connections come standard with the 34980A mainframe. If you choose t o modify or upgrade your test system I/O, the 34980A is system ready. Y ou can also easily co ...

  • Agilent Technologies 3499A/B/C - page 6

    6 W eb Page Interface The 34980A comes wit h a built-in detailed instr ument w eb page that allo ws you t o remot ely connect and communicate with the mainframe and installed modules. Y ou establish a L AN connection, eit her directly between t he 34980A and PC, or from the 34980A to an existing Local Area Netw ork. The instrument W eb page resides ...

  • Agilent Technologies 3499A/B/C - page 7

    7 T able 4. Command comparisons 34980A 3499A/B/C Close channel 10 on the module in slot 3 ROUT e:CLOS (@3010) [ROUT e:]CLOS (@310) Scan channels 0 through 40 on the module in slot 1 ROUT e:SCAN (@1001:1040) [ROUT e:]SCAN (@100:140) and channel(s) rat her than only three digits as the 3499A/B/C uses. Also, for t he 3499A/B/C t he [ROUT e] in the com ...

  • Agilent Technologies 3499A/B/C - page 8

    8 Scan Feature The scan feature is a sequence of alternating swit ch closures and measurements. This feature is pro vided by bot h the 34980A and a 3499A/B/C combined wit h a DMM or ot her measurement instrument. The 34980A increases the measurement scan abilities and offers more than twice the number of scanned channels within one scan list compar ...

  • Agilent Technologies 3499A/B/C - page 9

    9 Monitor Feature The 34980A monit or feature allo ws you t o monit or readings acquired by the switch/measure system. Y ou can also monitor readings acquired wit h t he 34980A internal DMM. T o monitor a measurement from the front panel, simply select the channel and press eit her t he Measure [DMM] or [Channel] button to see a continually updated ...

  • Agilent Technologies 3499A/B/C - page 10

    10 Switch and Measurement Connections Most often, t est syst ems must be f lexible enough to be easily mov ed to a new location or modified for different devices under test. Having a remo vable wiring ter minal block or a pre-wired cable is optimal in t hese situations. The module’s terminal and/or cable can sim ply be remov ed and replaced with ...

  • Agilent Technologies 3499A/B/C - page 11

    11 Summary Although the 3499A/B/C Switch/Control system has been a great addition to many test systems, the new 34980A now offers an even better module selection plus measurement capability , standard PC connections f or communication, and is easy to connect to modules. The wide of fering of plug-in modules f or t he 34980A enables you to select a ...

  • Agilent Technologies 3499A/B/C - page 12

    12 Appendix A – Command Reference/Comparison 34980A Commands ABORt CALCulate :A VERage:AVERage? :A VERage:CLEar :A VERage:COUNt? :A VERage: MAXimum? :A VERage:MAXimum:TIME? :A VERage:MINimum? :A VERage:MINimum:TIME? :A VERage:PTPeak? :LIMit:LOW er :LIMit:LOW er? :LIMit:LOW er:ST A T e :LIMit:LOW er:ST A T e? :LIMit:UPPer :LIMit:UPPer? :LIMit:UPPe ...

  • Agilent Technologies 3499A/B/C - page 13

    13 :CURRent:AC :CURRent[:DC] :DIGital:ST A T e :DIGital:WIDTh :FREQuency :FRESistance :PERiod :RESistance :TEMPerature :TOT alize [:VOL T age]:AC [:VOL T age][:DC] CONFigure? DA T A :LAST? :POINts:EVENt:THReshold :POINts:EVENt:THReshold? :POINts? :REMove? DIAGnostic :DMM:CYCLes:CLEar :DMM:CYCles? :RELay CYCles:CLEar :RELay:CYCLes? DISPlay [:ST A T ...

  • Agilent Technologies 3499A/B/C - page 14

    14 :CURRent:AC? :CURRent[:DC]? :DIGital[:<width>]? :DIGital[:BYTE]:BIT? :FREQuency? FRESistance? :PERiod? :RESistance? :TEMPerature? :TOT alize? [:VOL T age]:AC? [:VOL T age][:DC]? MEMory :ST A T e:CA T alog? :ST A T e:DELete :ST A T e:NAME :ST A T e:NAME? :ST A T e:RECall:AUTO :ST A T e:RECall:AUTO? :ST A T e:RECall:SELect :ST A T e:RECall:S ...

  • Agilent Technologies 3499A/B/C - page 15

    15 :SCAN :SCAN:ADD :SCAN:REMove :SCAN:SIZE? SAMPle :COUNt :COUNt? SENSe :CURRent:AC :BANDwidth :BANDwidth? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :CURRent[:DC] :APERture:ENABled? :APERture :NPLC :NPLC? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :RESolution :RESolution? :ZERO:AUTO :DIGital:DA T A[:<width>]? :DIGital:DA T A[BYTE]:BIT? :FREQuency ...

  • Agilent Technologies 3499A/B/C - page 16

    16 :RANGe:AUTO? :RESolution :RESolution? :ZERO:AUTO :FUNCtion :FUNCtion? :PERiod:APERture :PERiod:VOL T age:RANGe :VOL T age:RANGe? :VOL T age:RANGe:AUTO :VOL T age:RANGe:AUTO? :PERiod:ZERO:AUTO :RESistance:APERture :APERture? :ALPERture:ENABled? :NPLC :NPLC? :OCOMpensated :OCOMpensated? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :RESolution :RESoluti ...

  • Agilent Technologies 3499A/B/C - page 17

    17 [:DC]:NPLC? [:DC]:RANGe [:DC]:RANGe? [:DC]:RANGe:AUTO [:DC]:RANGe:AUTO? [:DC]:RESolution [:DC]RESolution [:DC]:ZERO:AUTO [:DC]:ZERO:AUTO? SOURce :CURRent[:LEV el] :CURRent[:LEV el]? :DIGital:DA T A[:<width>] :DIGital:DA T A[BYTE]:BIT :DIGital:ST A T e? :FUNCtion:CLOCk:EXT ernal:DIVisor :CLOCk[INT ernal]:PERiod :CLOCk:SOURce :CURRent:GAIN : ...

  • Agilent Technologies 3499A/B/C - page 18

    18 :ALARm:ENABle? :ALARm[:EVENt]? :MODule:ENABle :MODule:EVENt? :MODule:SLOT[n]:CONDition? :MODule:SLOT[n]:ENABle :MODule:SLOT[n][:EVENt]? :OPERation:CONDition? :OPERation:ENABle :OPERation:ENABle? :OPERation[:EVENt]? :PRESet :QUEStionable:CONDition? :QUEStionable:ENABle :QUEStionable:ENABle? :QUEStionable[:EVENt]? SYST em :ABUS:INT erlock:SIMulate ...

  • Agilent Technologies 3499A/B/C - page 19

    19 :TIME? :TIME:SCAN? :VERSion? TRACe:CA T alog? [:DA T A] [:DA T A]:DAC [:DA T A]:FUNCtion :DELete:ALL :DELete[:NAME] :FREE? :POINts? TRIGger :COUnt :COUNt? :DELay :DELay? :DELay:AUTO :DELay:AUTO? :SOURce :SOURce? :TIMer :TIMer? UNIT :TEMPerature :TEMPerature? IEEE-488.2 Common Commands *CLS *ESE *ESE? *ESR? *IDN? *OPC *OPC? *PSC *PSC? *RCL *RST * ...

  • Agilent Technologies 3499A/B/C - page 20

    Agilent T echnologies ’ T est and Measurement Support, Services, and Assistance Agilent T echnologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can ...

メーカー Agilent Technologies カテゴリー Switch

Agilent Technologies 3499A/B/Cのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 3499A/B/Cの取扱説明書
- Agilent Technologiesの製品カード
- パンフレット
- またはAgilent Technologies 3499A/B/Cの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Agilent Technologies 3499A/B/Cの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Agilent Technologies 3499A/B/Cの取り付け説明書、サービスマニュアル、簡易説明書、またはAgilent Technologies 3499A/B/Cのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Agilent Technologies 3499A/B/Cの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Agilent Technologies 3499A/B/Cデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAgilent Technologies 3499A/B/Cを使用するのを助ける技術的文書のことです。説明書は通常、全てのAgilent Technologies 3499A/B/Cユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Agilent Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Agilent Technologies 3499A/B/Cの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAgilent Technologies 3499A/B/Cの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Agilent Technologies 3499A/B/Cに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Agilent Technologies 3499A/B/Cデバイスの基本機能を使うにあたってのヒント。 Agilent Technologies 3499A/B/Cのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Agilent Technologies 3499A/B/Cに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAgilent Technologies 3499A/B/Cのメーカー/サービスへの連絡先に関する情報。

Agilent Technologies 3499A/B/Cについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAgilent Technologies 3499A/B/Cの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAgilent Technologies 3499A/B/Cで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)