    036-21031 -004 Rev. A (0603) FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE ® TECHNIC AL GUIDE STELLAR PLUS TM 12 SEER SPLIT -SYSTEM HEA T P UMPS MOD ELS: E*FH018 Thru E*FH06 0 (1.5 THRU 5 NOMINAL TONS) Due to cont inuous produc t improvem ent, specifi cations are subje ct to change w ithout notice. Vis it us on the web at www ...

  • York E*FH060 - page 2

    036-2103 1-004 Re v. A (0603 ) 2 Unitary Produ cts Grou p All dim ensions are in inches. They are subje ct to ch ange withou t notice. Certif ied dimens ions will be provide d upon request. PHYSICAL AND ELECTRICAL DA T A MODEL E4FH018 E4FH024 E4FH030 E4F H036 E4FH045 E5FH048 E4FH060 Unit Supply V olt age 208/230-1-60 Normal V olt age Range 1 1. Rat ...

  • York E*FH060 - page 3

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 3 PROCEDURES: 1. Unit factory charge list ed on the unit nameplate includes refigerant for the condenser , the smallest evaporator and for 15 f eet of intercon- necting line tubing. 2. V erify the orifice size and the additional charge required for the specific evaporator coil in the system using ...

  • York E*FH060 - page 4

    036-2103 1-004 Re v. A (0603 ) 4 Unitary Produ cts Grou p - = No t appl icab le COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 1. G2 FD co ils av ailab le wi th a f acto ry in sta lle d hori zont al drain pan. See p rice pag es for spec ific m ode l number . COO LING MODEL ELEC TRIC HEA T K W 2 2. Sing le phas e unit ...

  • York E*FH060 - page 5

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 5 * Require s a 2F D Blower T ime De lay unl ess a standa rd furn ace is e quipped with one . ** Refer to Qu ick Selection Chart for specific fu rnace m atch-u p. COOLING CAP ACITY - With Up flow , Downflow and Horizont al Furnace and Coils UNIT MODE L FURNACE** COIL MODEL COO LING NOMINAL AIRFLO ...

  • York E*FH060 - page 6

    036-2103 1-004 Re v. A (0603 ) 6 Unitary Produ cts Grou p HEA TING PERFORMANCE - Air Handler and Mu lti-position Coils UNIT MODE L COIL 1 MODE L ARI HEA TING 2 OUTD O O R TE M P 3 47 ° F 17 ° FH S P F- 3 ° F 7 ° F1 7 ° F 27 ° F 37 ° F 47 ° F5 7 ° F MBH COP MBH COP STD. V . S. MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW E4FH018 F2RP/F2 ...

  • York E*FH060 - page 7

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 7 COP equa ls MBH output divided b y (total KW inp ut x 3.4 12). HSPF ( Heating Seasonal Perfo rmanc e Factor) is the to tal heati ng outpu t duri ng a nor mal ann ual usa ge per iod for heating divided by t he total ele ctric power input du ring th e same period . — = Not Applicable. HEA TING ...

  • York E*FH060 - page 8

    036-2103 1-004 Re v. A (0603 ) 8 Unitary Produ cts Grou p ACCESSORIES Refer to Price Ma nual for sp ecific mod el numbe rs. St art Ass ist Kit (2SA067*) Blow er Ti me Del ay - Avail able to in crease ef fic iency whe n inst alled. Ins tal ls on indoor sec tion an d maint ains blowe r for approxi mately on e minute af ter c ooling therm osta t has b ...

  • York E*FH060 - page 9

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 9 TYPICAL INST ALLA TION TYPICAL FIELD WIRING - (AIR HANDLER / ELECTRICAL HEA T ) THERMOST A T TO INDOOR BLOWER TO COIL NEC CLASS 2 WIRING NEC CLASS 1 WIRING TO POWER SUPPL Y WEA THERPROOF DISCONNECT SWITCH Seal open ing(s) with per magum or equivalent 24” SERVICE ACCESS CLEARANCE 48” OVERHEA ...

  • York E*FH060 - page 10

    036-2103 1-004 Re v. A (0603 ) 10 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. NOTE: For dry bu lb te mpera ture s dif fer ent th an t hose liste d (bet ween 73-87 F), s e nsib le ca pac ity in crea ses b y 1060 BTUH pe r 10 00 CFM per deg ree ab ove t he listed tem pera ture an d decreas es by 1 ...

  • York E*FH060 - page 11

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 11 Multipliers for determining the performance with oth er indoor sections. NOTE: For dry b ulb tem peratu res differe nt than tho se list ed (be tween 7 3-87 F), sensibl e capacity increase s by 10 60 BTUH p er 100 0 CFM per de gree a bove th e lis t ed t e mper atur e and de cre a ses by 106 0 ...

  • York E*FH060 - page 12

    036-2103 1-004 Re v. A (0603 ) 12 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. NOTE: For dry bu lb te mpera ture s dif fer ent th an t hose liste d (bet ween 73-87 F), s e nsib le ca pac ity in crea ses b y 1060 BTUH pe r 10 00 CFM per deg ree ab ove t he listed tem pera ture an d decreas es by 1 ...

  • York E*FH060 - page 13

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 13 Multipliers for determining the performance with oth er indoor sections. NOTE: For dry b ulb tem peratu res differe nt than tho se list ed (be tween 7 3-87 F), sensibl e capacity increase s by 10 60 BTUH p er 100 0 CFM per de gree a bove th e lis t ed t e mper atur e and de cre a ses by 106 0 ...

  • York E*FH060 - page 14

    036-2103 1-004 Re v. A (0603 ) 14 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. NOTE: For dry bu lb te mpera ture s dif fer ent th an t hose liste d (bet ween 73-87 F), s e nsib le ca pac ity in crea ses b y 1060 BTUH pe r 10 00 CFM per deg ree ab ove t he listed tem pera ture an d decreas es by 1 ...

  • York E*FH060 - page 15

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 15 Multipliers for determining the performance with oth er indoor sections. NOTE: For dry b ulb tem peratu res differe nt than tho se list ed (be tween 7 3-87 F), sensibl e capacity increase s by 10 60 BTUH p er 100 0 CFM per de gree a bove th e lis t ed t e mper atur e and de cre a ses by 106 0 ...

  • York E*FH060 - page 16

    036-2103 1-004 Re v. A (0603 ) 16 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. NOTE: For dry bu lb te mpera ture s dif fer ent th an t hose liste d (bet ween 73-87 F), s e nsib le ca pac ity in crea ses b y 1060 BTUH pe r 10 00 CFM per deg ree ab ove t he listed tem pera ture an d decreas es by 1 ...

  • York E*FH060 - page 17

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 17 Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO. E4FH018S06 EV APORA TOR COIL MODEL NO. F 2RP/F2FP024 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP . ENTERING INDOOR COIL ID CF M 600 650 700 MBTUH K.W . C. O.P . MBTUH K. ...

  • York E*FH060 - page 18

    036-2103 1-004 Re v. A (0603 ) 18 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO. E4FH024S06 EV APORA TOR COIL MODEL NO. F 2RP/F2FP030 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP . ENTERING INDOOR COIL ID CF M 750 800 850 MBTUH K.W . C.O.P . MBTUH ...

  • York E*FH060 - page 19

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 19 Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO E4FH30S06 EV APORA TOR COIL MODEL NO G2FD030(S,H)17 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP . ENTERING INDOOR COIL ID CF M 950 1050 1 150 MBTUH K.W . C. O.P . MBTUH K ...

  • York E*FH060 - page 20

    036-2103 1-004 Re v. A (0603 ) 20 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO. E4FH036S06 EV APORA TOR COIL MODEL NO. F 2RP/F2FP036 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP . ENTERING INDOOR COIL ID CF M 1 150 1250 1350 MBTUH K.W . C.O.P . MB ...

  • York E*FH060 - page 21

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 21 Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO E4FH042S06 EV APORA TOR COIL MODEL NO F2RP/F2FP042 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP . ENTERING INDOOR COIL ID CF M 1200 1400 1000 MBTUH K.W . C. O.P . MBTUH K. ...

  • York E*FH060 - page 22

    036-2103 1-004 Re v. A (0603 ) 22 Unitary Produ cts Grou p Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO E5FH048S06 EV APORA TOR COIL MODEL NO F2FP048 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP . ENTERING INDOOR COIL ID CF M 1450 1600 1750 MBTUH K.W . C.O.P . MBTUH K.W . ...

  • York E*FH060 - page 23

    036-21031 -004 Rev. A (0603) Unitary Pro ducts Group 23 Multipliers for determining the performance with oth er indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO E4FH060S06 EV APORA TOR COIL MODEL NO G2FD060(S,H)24 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP . ENTERING INDOOR COIL ID CF M 1700 1850 2000 MBTUH K.W . C. O.P . MBTUH ...

  • York E*FH060 - page 24

    Subject to change without notice. Printed in U.S.A. 036-21031-004 Rev. A (0603) Copyright © by Y ork International Corp. 2003. All rights reserved. Supersedes: 036-21031-003 Rev . A (0403) Unit ary 5005 Norma n Product Y ork OK Group Drive 7306 9 MA TCHING INDOOR COMP ONENTS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW ...

Fabricante York Categoría Air Conditioner

Los documentos del dispositivo York E*FH060 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos York
- manuales de instrucciones E*FH060
- hojas de producto York
- folletos informativos
- o etiquetas energéticas York E*FH060
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones York E*FH060.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje York E*FH060, instrucciones de servicio, instrucciones cortas o instrucciones de usuario York E*FH060. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto York E*FH060.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo York E*FH060, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar York E*FH060. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de York E*FH060.

El manual de instrucciones completo de York debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual York E*FH060 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice York E*FH060, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de York E*FH060 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo York E*FH060 - que deben facilitarnos los primeros pasos durante el uso de York E*FH060
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con York E*FH060
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de York E*FH060 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de York E*FH060?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con York E*FH060, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con York E*FH060 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)