Manual de instrucciones CDA HCG500

12 de páginas 0.43 mb
Descargar

Pasar a la página of 12

Summary
  • CDA HCG500 - page 1

    Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshir e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu Passionate about style HCG500 / HCG520 gas hobs Manual for Inst allation, Use and Maintenanc e ...

  • CDA HCG500 - page 2

    Important The CDA Gr oup Ltd cannot be held r esponsible for injuries or losses caused by incorr ect use or installation of this product. Please note that CDA reserv e the right to invalidate the guarant ee supplied with this product following incorr ect installation or misuse of the appliance or use in a commer cial envir onment. This appliance is ...

  • CDA HCG500 - page 3

    Using your hob Fig. 1 2 3 1 4 5 6 7 8 Gas burners: 1 . Rapid burner 3.0kW 2. Left Semi-Rapid burner 1 .75kW 3. Right Semi-Rapid burner 1 .75kW 4. Auxiliary burner 1 .0kW Contr ol panel: 5. Right Semi-Rapid burner contr ol knob 6. Left Semi-Rapid burner c ontrol knob 7 . Rapid burner contr ol knob 8. Auxiliary burner contr ol knob This appliance is ...

  • CDA HCG500 - page 4

    Igniting the Burners T o ignite the burner s, follo w these instructions: 1 . Lightly press the control knob (shown on the right) and turn the knob anti- clockwise to the maximum position. Pr ess and hold the control down t o begin the igni tion pr ocess (a cli cking sound will be hear d). 2. Once the burner is lit, adjust the burner power to the r ...

  • CDA HCG500 - page 5

    T otal rated gas input : 7 .5kW Mains electrical voltage: 230 – 240V ac T otal rated electrical consumption: <1W If your Hob is not w orking 1 . Check that the mains supply has not been swit ched off. 2. Check that the fuse in the spur has not blown. 3. Ensure that the burner components ar e not excessively soiled as this can lead t o ignition ...

  • CDA HCG500 - page 6

    DOUBLE POLE SWIT CHED FUSE SPUR OUTLET USE A 3 AMP FUSE Mains Electricity Connection THIS APPLIANCE MUST BE C ONNECTED T O THE MAINS SUPPL Y BY A CO MPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWIT CHED FUSE SPUR OUTLET AND PRO TECTED BY A 3A FUSE. W e r ecommend that the appliance is connected by a qualified electrician, who is a member ...

  • CDA HCG500 - page 7

    Room V olume (m 3 ) 5 6 to 1 0 6 to 1 1 1 1 or more Air V ent Requir ed (cm 3 ) 1 00 50 No permanent vent r equired if a door opens to the outside None requir ed Gas Supply Requir ements IMPOR T ANT : THIS APPLIANCE SHOULD BE FITTED BY A GAS S AFE REGIS TERED FITTER OR O THER SUIT ABL Y QUALIFIED PERSON. • This inst allation must comply with the ...

  • CDA HCG500 - page 8

    Natur al Gas to LPG Con v ersion This hob can be converted from natural gas to pr opane operation at a nominal inlet pressure of 37mbar , or butane operation at a nominal inlet pressur e of 28/30mbar . This conver sion must only be carried out by a competent person (i.e. a Gas Safe r egister ed fitter). Instructions to fit r eplacement injector s ...

  • CDA HCG500 - page 9

    Fitting the Hob Unpacking the hob: T ake care not to lose or mishandle an y parts. Fitting position of the hob: This appliance must be installed a minimum of 50mm from any back wall and a minimum of 1 85mm away from any adjacent vertical surfaces, e.g. a t all cupboar d end panel. This ma y be reduced to 1 00mm if the adjac ent surfac e is resistan ...

  • CDA HCG500 - page 10

    How t o install the hob: Overall dimensions of the hob: Width: 585mm Depth: 500mm W orktop cut-out dimensions: Width: 550mm Depth: 4 70mm 1 . Make the requir ed hole in the worktop. Befor e doing this, you must check the instructions supplied with any cooker hood to ensure that you will have the requir ed clearance. The cut-out (Fig.4) shows a 65mm ...

  • CDA HCG500 - page 11

    Not es : ...

  • CDA HCG500 - page 12

    Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshir e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu Passionate about style T o c ontact our Customer Car e Department, or for Service, please contact us on the det ails below . ...

Fabricante CDA Categoría Cooktop

Los documentos del dispositivo CDA HCG500 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos CDA
- manuales de instrucciones HCG500
- hojas de producto CDA
- folletos informativos
- o etiquetas energéticas CDA HCG500
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones CDA HCG500.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje CDA HCG500, instrucciones de servicio, instrucciones cortas o instrucciones de usuario CDA HCG500. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto CDA HCG500.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo CDA HCG500, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar CDA HCG500. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de CDA HCG500.

El manual de instrucciones completo de CDA debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual CDA HCG500 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice CDA HCG500, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de CDA HCG500 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo CDA HCG500 - que deben facilitarnos los primeros pasos durante el uso de CDA HCG500
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con CDA HCG500
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de CDA HCG500 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de CDA HCG500?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con CDA HCG500, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con CDA HCG500 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)