  • Mercury PR0091 - page 1

    Mercur y 6-5 Stat – Installation & User Guide Mercury 6-5 5 Channel Thermost at Inst allation Guide For Product: - PR0091 En sur e t ha t a ll po wer is sw it ched of f b efore inst a lling or ma int a ini n g this product Revision 1.2 Page 1 of 21 ...

  • Mercury PR0091 - page 2

    Mercur y 6-5 Stat – Installation & User Guide Table of Contents: THE MERCURY RANGE .................................................................................................................................... 3 Description .................................................................................................................. ...

  • Mercury PR0091 - page 3

    Mercur y 6-5 Stat – Installation & User Guide The Mer cury Rang e From Resource Data Managemen t This documentation refers to the Mercury 6-5 - 5 Channel Thermostat Description The Mercury 5 Channel Thermostat ha s 5 thermostat f unctions. They can be configure d for independent use, where each function is con trolled by an individual probe o ...

  • Mercury PR0091 - page 4

    Mercur y 6-5 Stat – Installation & User Guide Connections All connections are ma de to the back of the controller. The dia gram below shows the connection detail. Inputs and outputs are assigne d according to the chosen config uration. See Specification for further details on connectio ns. ! Do not connect an earth . Input/Output Allocation T ...

  • Mercury PR0091 - page 5

    Mercur y 6-5 Stat – Installation & User Guide Setting up the controller Access to the controller ca n be achieved several ways • Through the front mounted buttons • Direct access by PC or palm top into the rear co mms port. This requires a software package available on the RDM website • Through the RDM Data Directo r or Data Manager. Se ...

  • Mercury PR0091 - page 6

    Mercur y 6-5 Stat – Installation & User Guide Recommended set-up method If you are not connecting to a network and want to set up the co ntroller through the buttons we recommend you use the following order from the function menu. rtc. Real time clock (This will automa tically synchronise on netw ork systems) a. Use the up or down buttons to ...

  • Mercury PR0091 - page 7

    Mercur y 6-5 Stat – Installation & User Guide Parameter Tables: Parameter table for 5 Channel Thermosta t En sur e t ha t a ll po wer is Number Parameter Range o C ( o F ) Step Units Default P-01 Stat1 Temp Cut-In -49 to 30 o C (-56.2 to 86) 0.1 Deg 15.0 P-02 Stat1 Diff 0 to 10 o C (32 to 50) 0.1 Deg 5.0 P-03 Stat1 Select 0 = Off 1 = Timer 2 ...

  • Mercury PR0091 - page 8

    Mercur y 6-5 Stat – Installation & User Guide Parameter table for 5 Channe l Thermostat Continued....... Number Parameter Range o C ( o F ) Step Units Default P-31 Stat4 Temp Cut-In -49 to 30 o C (-56.2 to 86) 0.1 Deg 15.0 P-32 Stat4 Diff 0 to 10 o C (32 to 50) 0.1 Deg 5.0 P-33 Stat4 Select 0 = Off 1 = Timer 2 = Probe 1 3 = Probe 2 4 = Probe ...

  • Mercury PR0091 - page 9

    Mercur y 6-5 Stat – Installation & User Guide Parameter table for 5 Channe l Thermostat Continued....... Number Parameter Range Step Units Default P79 Tuesday On Time 1 00:00 to 23:59 00:01 hh:mm 08:00 P80 Tuesday Off Time 1 00:00 to 23:59 00:01 hh:mm 20:00 P81 Tuesday On Time 2 00:00 to 23:59 00:01 hh:mm 08:00 P82 Tuesday Off Time 2 00:00 to ...

  • Mercury PR0091 - page 10

    Mercur y 6-5 Stat – Installation & User Guide Network Configuration The final section to set-up is the network addres s. In all instance s, this mu st be done before the controller is plugged into the site network. The controllers have an aut o-initialise function, whic h will automatically log the device onto the site network. If the wrong a ...

  • Mercury PR0091 - page 11

    Mercur y 6-5 Stat – Installation & User Guide Over-ride Operation The 5 Channel Thermostat can op erate either from its in ternal channel time settings or from a network Data Manager GP Timer channe l (P70 sets the mode either loca l or remo te). If the 5 Chann el Thermostat is set up to use the remote timing channels it reverts to local mode ...

  • Mercury PR0091 - page 12

    Mercur y 6-5 Stat – Installation & User Guide Normal Operation During normal operation, the controlle r will display "on". If the 5 Channel Thermostat is on a network and on- line, the green network LED will be on . If any alarms are generated the r ed LED will light. The yellow LED has no function and will not light. Frost Detect T ...

  • Mercury PR0091 - page 13

    Mercur y 6-5 Stat – Installation & User Guide Thermostat Cooling/Heating Operation The diagrams below outline the operatio n of a channel when it is configured fo r he ating or cooling applications. In this instance the 5 Channel Thermo stat’s local timer is on. Cooling Thermostat graph Heating Thermostat grap h En sur e t ha t a ll po wer ...

  • Mercury PR0091 - page 14

    Mercur y 6-5 Stat – Installation & User Guide Viewing Apart from setting up the controller, you can also view the status of the inputs a nd outputs. 1. IO. View Inputs / Outputs and States a. From the function menu, select “IO”, press enter b. You can now scroll through the IO tables as set out below. The tabl es you view will depend on t ...

  • Mercury PR0091 - page 15

    Mercur y 6-5 Stat – Installation & User Guide Network Alarms The table below shows the text and associated type numbe r that is se nt to the sy stem "front end". The type number is normally used to provide different alarm actions. Alarm text Type Probe 1 Faulty 6 Probe 2 Faulty 6 Probe 3 Faulty 6 Probe 4 Faulty 6 Probe 5 Faulty 6 Ch ...

  • Mercury PR0091 - page 16

    Mercur y 6-5 Stat – Installation & User Guide Specification General Power requirements: Supply Voltage Range: 100 - 240 Vac ±10% Supply Frequency: 50 - 60 Hz ±10% Maximum supply current: <1 Amp (With no relay loads) Typical supply current: <0.5 Amp Operating temperature range: +5 0 C to +50 0 C Operating Humidity: 80% maximum Storage ...

  • Mercury PR0091 - page 17

    Mercur y 6-5 Stat – Installation & User Guide Inputs: Input resistance: 3.01K Ohms (for PTC or NTC type probes) Input type PT1000 NTC2000 N T C 2 k 2 5 Comms: RS232 with flow control En sur e t ha t a ll po wer is sw it ched of f b efore inst a lling or ma int a ini n g this product Revision 1.2 Page 17 of 21 ...

  • Mercury PR0091 - page 18

    Mercur y 6-5 Stat – Installation & User Guide Installation: Panel Cut-out: 72mm 93mm 34mm 17mm 2 holes: 3.5mm dia. Fixing: The controller can be fixed either by 2 X M3 screws fr om the re ar or by the plastic retaining de vice (PR0329), obtainable from RDM. Clearances: The controller must have 5mm cleara nce above the top and below bottom, an ...

  • Mercury PR0091 - page 19

    Mercur y 6-5 Stat – Installation & User Guide Wiring: Relay 4 and 5 N/O are fed from the supply input ! Note: Suitable mechanical restraints on the wi ring to the controller may be required; depen dant on cable types, to prevent undue stress or distorti on on the controlle r connectors. Over-ride input Resistors: Example of 820-Ohm resistor f ...

  • Mercury PR0091 - page 20

    Mercur y 6-5 Stat – Installation & User Guide Fuse: The host equipment must provide a suitable exter nal over-curre nt protection d evice such as: - Fuse: 6.3A, 240 Vac Antisurge (T) HRC confor ming to IEC 60127 (Relay 4 & 5 fully loaded) Or MCB: 8A, 240 Vac Type C conforming to BS EN 60898 (Relay 4 & 5 fully loaded) Cleaning: Do not ...

  • Mercury PR0091 - page 21

    Mercur y 6-5 Stat – Installation & User Guide Revision History Revision Date Change s 1.0 27/10/2006 First Issue 1.1 01/03/2007 General Tidy Up 1.2 05/03/2007 Removal of over-ride des cripti on (for when a chann el is co nfigured as a timer). En sur e t ha t a ll po wer is sw it ched of f b efore inst a lling or ma int a ini n g this product ...

Fabricante Mercury Categoría Thermostat

Los documentos del dispositivo Mercury PR0091 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Mercury
- manuales de instrucciones PR0091
- hojas de producto Mercury
- folletos informativos
- o etiquetas energéticas Mercury PR0091
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Mercury PR0091.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Mercury PR0091, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Mercury PR0091. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Mercury PR0091.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Mercury PR0091, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Mercury PR0091. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Mercury PR0091.

El manual de instrucciones completo de Mercury debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Mercury PR0091 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Mercury PR0091, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Mercury PR0091 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Mercury PR0091 - que deben facilitarnos los primeros pasos durante el uso de Mercury PR0091
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Mercury PR0091
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Mercury PR0091 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Mercury PR0091?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Mercury PR0091, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Mercury PR0091 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)