    Mercur y 6-5 Stat – Installation & User Guide Mercury 6-5 5 Channel Thermost at Inst allation Guide For Product: - PR0091 En sur e t ha t a ll po wer is sw it ched of f b efore inst a lling or ma int a ini n g this product Revision 1.2 Page 1 of 21 ...

  • Mercury PR0091 - page 2

    Mercur y 6-5 Stat – Installation & User Guide Table of Contents: THE MERCURY RANGE .................................................................................................................................... 3 Description .................................................................................................................. ...

  • Mercury PR0091 - page 3

    Mercur y 6-5 Stat – Installation & User Guide The Mer cury Rang e From Resource Data Managemen t This documentation refers to the Mercury 6-5 - 5 Channel Thermostat Description The Mercury 5 Channel Thermostat ha s 5 thermostat f unctions. They can be configure d for independent use, where each function is con trolled by an individual probe o ...

  • Mercury PR0091 - page 4

    Mercur y 6-5 Stat – Installation & User Guide Connections All connections are ma de to the back of the controller. The dia gram below shows the connection detail. Inputs and outputs are assigne d according to the chosen config uration. See Specification for further details on connectio ns. ! Do not connect an earth . Input/Output Allocation T ...

  • Mercury PR0091 - page 5

    Mercur y 6-5 Stat – Installation & User Guide Setting up the controller Access to the controller ca n be achieved several ways • Through the front mounted buttons • Direct access by PC or palm top into the rear co mms port. This requires a software package available on the RDM website • Through the RDM Data Directo r or Data Manager. Se ...

  • Mercury PR0091 - page 6

    Mercur y 6-5 Stat – Installation & User Guide Recommended set-up method If you are not connecting to a network and want to set up the co ntroller through the buttons we recommend you use the following order from the function menu. rtc. Real time clock (This will automa tically synchronise on netw ork systems) a. Use the up or down buttons to ...

  • Mercury PR0091 - page 7

    Mercur y 6-5 Stat – Installation & User Guide Parameter Tables: Parameter table for 5 Channel Thermosta t En sur e t ha t a ll po wer is Number Parameter Range o C ( o F ) Step Units Default P-01 Stat1 Temp Cut-In -49 to 30 o C (-56.2 to 86) 0.1 Deg 15.0 P-02 Stat1 Diff 0 to 10 o C (32 to 50) 0.1 Deg 5.0 P-03 Stat1 Select 0 = Off 1 = Timer 2 ...

  • Mercury PR0091 - page 8

    Mercur y 6-5 Stat – Installation & User Guide Parameter table for 5 Channe l Thermostat Continued....... Number Parameter Range o C ( o F ) Step Units Default P-31 Stat4 Temp Cut-In -49 to 30 o C (-56.2 to 86) 0.1 Deg 15.0 P-32 Stat4 Diff 0 to 10 o C (32 to 50) 0.1 Deg 5.0 P-33 Stat4 Select 0 = Off 1 = Timer 2 = Probe 1 3 = Probe 2 4 = Probe ...

  • Mercury PR0091 - page 9

    Mercur y 6-5 Stat – Installation & User Guide Parameter table for 5 Channe l Thermostat Continued....... Number Parameter Range Step Units Default P79 Tuesday On Time 1 00:00 to 23:59 00:01 hh:mm 08:00 P80 Tuesday Off Time 1 00:00 to 23:59 00:01 hh:mm 20:00 P81 Tuesday On Time 2 00:00 to 23:59 00:01 hh:mm 08:00 P82 Tuesday Off Time 2 00:00 to ...

  • Mercury PR0091 - page 10

    Mercur y 6-5 Stat – Installation & User Guide Network Configuration The final section to set-up is the network addres s. In all instance s, this mu st be done before the controller is plugged into the site network. The controllers have an aut o-initialise function, whic h will automatically log the device onto the site network. If the wrong a ...

  • Mercury PR0091 - page 11

    Mercur y 6-5 Stat – Installation & User Guide Over-ride Operation The 5 Channel Thermostat can op erate either from its in ternal channel time settings or from a network Data Manager GP Timer channe l (P70 sets the mode either loca l or remo te). If the 5 Chann el Thermostat is set up to use the remote timing channels it reverts to local mode ...

  • Mercury PR0091 - page 12

    Mercur y 6-5 Stat – Installation & User Guide Normal Operation During normal operation, the controlle r will display "on". If the 5 Channel Thermostat is on a network and on- line, the green network LED will be on . If any alarms are generated the r ed LED will light. The yellow LED has no function and will not light. Frost Detect T ...

  • Mercury PR0091 - page 13

    Mercur y 6-5 Stat – Installation & User Guide Thermostat Cooling/Heating Operation The diagrams below outline the operatio n of a channel when it is configured fo r he ating or cooling applications. In this instance the 5 Channel Thermo stat’s local timer is on. Cooling Thermostat graph Heating Thermostat grap h En sur e t ha t a ll po wer ...

  • Mercury PR0091 - page 14

    Mercur y 6-5 Stat – Installation & User Guide Viewing Apart from setting up the controller, you can also view the status of the inputs a nd outputs. 1. IO. View Inputs / Outputs and States a. From the function menu, select “IO”, press enter b. You can now scroll through the IO tables as set out below. The tabl es you view will depend on t ...

  • Mercury PR0091 - page 15

    Mercur y 6-5 Stat – Installation & User Guide Network Alarms The table below shows the text and associated type numbe r that is se nt to the sy stem "front end". The type number is normally used to provide different alarm actions. Alarm text Type Probe 1 Faulty 6 Probe 2 Faulty 6 Probe 3 Faulty 6 Probe 4 Faulty 6 Probe 5 Faulty 6 Ch ...

  • Mercury PR0091 - page 16

    Mercur y 6-5 Stat – Installation & User Guide Specification General Power requirements: Supply Voltage Range: 100 - 240 Vac ±10% Supply Frequency: 50 - 60 Hz ±10% Maximum supply current: <1 Amp (With no relay loads) Typical supply current: <0.5 Amp Operating temperature range: +5 0 C to +50 0 C Operating Humidity: 80% maximum Storage ...

  • Mercury PR0091 - page 17

    Mercur y 6-5 Stat – Installation & User Guide Inputs: Input resistance: 3.01K Ohms (for PTC or NTC type probes) Input type PT1000 NTC2000 N T C 2 k 2 5 Comms: RS232 with flow control En sur e t ha t a ll po wer is sw it ched of f b efore inst a lling or ma int a ini n g this product Revision 1.2 Page 17 of 21 ...

  • Mercury PR0091 - page 18

    Mercur y 6-5 Stat – Installation & User Guide Installation: Panel Cut-out: 72mm 93mm 34mm 17mm 2 holes: 3.5mm dia. Fixing: The controller can be fixed either by 2 X M3 screws fr om the re ar or by the plastic retaining de vice (PR0329), obtainable from RDM. Clearances: The controller must have 5mm cleara nce above the top and below bottom, an ...

  • Mercury PR0091 - page 19

    Mercur y 6-5 Stat – Installation & User Guide Wiring: Relay 4 and 5 N/O are fed from the supply input ! Note: Suitable mechanical restraints on the wi ring to the controller may be required; depen dant on cable types, to prevent undue stress or distorti on on the controlle r connectors. Over-ride input Resistors: Example of 820-Ohm resistor f ...

  • Mercury PR0091 - page 20

    Mercur y 6-5 Stat – Installation & User Guide Fuse: The host equipment must provide a suitable exter nal over-curre nt protection d evice such as: - Fuse: 6.3A, 240 Vac Antisurge (T) HRC confor ming to IEC 60127 (Relay 4 & 5 fully loaded) Or MCB: 8A, 240 Vac Type C conforming to BS EN 60898 (Relay 4 & 5 fully loaded) Cleaning: Do not ...

  • Mercury PR0091 - page 21

    Mercur y 6-5 Stat – Installation & User Guide Revision History Revision Date Change s 1.0 27/10/2006 First Issue 1.1 01/03/2007 General Tidy Up 1.2 05/03/2007 Removal of over-ride des cripti on (for when a chann el is co nfigured as a timer). En sur e t ha t a ll po wer is sw it ched of f b efore inst a lling or ma int a ini n g this product ...

メーカー Mercury カテゴリー Thermostat

Mercury PR0091のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PR0091の取扱説明書
- Mercuryの製品カード
- パンフレット
- またはMercury PR0091の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Mercury PR0091の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Mercury PR0091の取り付け説明書、サービスマニュアル、簡易説明書、またはMercury PR0091のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Mercury PR0091の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Mercury PR0091デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMercury PR0091を使用するのを助ける技術的文書のことです。説明書は通常、全てのMercury PR0091ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mercuryの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Mercury PR0091の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMercury PR0091の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Mercury PR0091に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Mercury PR0091デバイスの基本機能を使うにあたってのヒント。 Mercury PR0091のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Mercury PR0091に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMercury PR0091のメーカー/サービスへの連絡先に関する情報。

Mercury PR0091についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMercury PR0091の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMercury PR0091で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)