Manual de instrucciones Hafler TRM6.1

36 de páginas 3.55 mb
Descargar

Pasar a la página of 36

Summary
  • Hafler TRM6.1 - page 1

    ...

  • Hafler TRM6.1 - page 2

    Declaration of Conformity Application of Council Directive: 73/23/EEC (low voltage dir ective) Standard(s) to which Conformity is Declared: EN55103-1 EN55103-2 EN60065 (safety) Manufacturer ’ s Name: Hafler Manufacturer ’ s Address: 546 South Rockford Drive, T empe, Arizona 85281, U.S.A. Importer ’ s Name: ____________________________________ ...

  • Hafler TRM6.1 - page 3

    TRM6.1 Free Field Frequency Response 55Hz – 21kHz, ±2dB Peak Acoustic Output ≥ 1 19dB (per pair w/music @ 1m) T otal Harmonic Distortion (THD) <0.5%, 150Hz – 21kHz (90dB @ 1m on axis) High Frequency Driver 1" (25mm) V ifa Soft Dome Low Frequency Driver 6.5" (165mm) Polypropylene Cone/ Inverted Nitrile Rubber Surround Magneticall ...

  • Hafler TRM6.1 - page 4

    NOTICE - IMPOR T ANT SAFETY INFORMA TION 1. READ INSTRUCTIONS All the safety and operating instructions of your Hafler equipment should be read before power is applied to the equipment. 2. RET AIN OWNER'S MANUAL These safety and operating instructions should be retained for future reference. 3. HEED W ARNINGS All warnings on the equipment and ...

  • Hafler TRM6.1 - page 5

    – iii – ADVER TENCIA – INFORMACION DE SEGURIDAD IMPOR T ANTE 1. LEA LAS INSTRUCCIONES T odas las instrucciones de seguidad y operaci ó n de su equipo Hafler , deben ser le í das antes de que el equipo sea conectado dl é ctricamente. 2. CONSERVE EL MANUAL DEL PROPIET ARIO Estas instrucciones de seguridad y operaci ó n, deben ser conser- va ...

  • Hafler TRM6.1 - page 6

    – iv – A TTENTION: INFORMA TIONS IMPOR T ANTES DE S É CURIT É 1. LIRE LES INSTRUCTIONS Le mode d'emploi et les mesures de s é curit é de votre é quipement Hafler devraient ê tre consult é s avant sa mise en marche. 2. CONSERVER LE GUIDE DE L'UTILISA TEUR Le mode e'emploi et les mesures de s é curit é devraient ê tre con ...

  • Hafler TRM6.1 - page 7

    ACHTUNG – WICHTIGE SICHERHEITS – INFORMA TIONEN 1. INSTRUKTIONEN LESEN Alle Sicherheits- und Operationshinweise Ihres Hafler Equipments sollten vor der Inbetriebnahme gelesen werden. 2. BETRIEBSANLEITUNG AUFBEW AHREN Bewahren Sie die Bedienungsanleitung sorgf ä ltig auf, damit Sie in dieser auch in Zukunft nachschlagen k ö nnen. 3. W ARNUNGEN ...

  • Hafler TRM6.1 - page 8

    – vi – NOT ARE – IMPOR T ANTI INFORMAZIONI SULLA SICUREZZA 1. LEGGETE LE ISTRUZIONI T utte le istruzioni riguardanti la sicurezza ed il funzionamento devono essere lette prima di applicare tensione all'apparato. 2. CONSERV A TE IL MANUALE Queste istruzioni riguardanti la sicurezza ed il funzionamento devono essere conservate come riferim ...

  • Hafler TRM6.1 - page 9

    T ABLE OF C ONTENTS PERFORMANCE SPECIFICA TIONS ........................................................................................................................i Frequency Response Graph Energy T ime Curve Graph Horizontal Polar Response Graph Dimensions SAFETY PRECAUTIONS .................................................................... ...

  • Hafler TRM6.1 - page 10

    I NTRODUCTION – 1 – Thank you and congratulations on your purchase of the HAFLER TRM6.1 reference monitor , the world's finest brand in professional audio equipment. The TRM6.1 ( T rans • ana R eference M onitor) is a bi-amplified, two-way near field monitor offering unmatched quality and performance in a truly professional grade product ...

  • Hafler TRM6.1 - page 11

    Amplifie – 2 – MEHSA ( M aximum E fficiency H eat S ink A pplication) MEHSA is a proprietary process that yields up to 5 times better heat transfer than traditional FET mounting techniques using the exact same components. A multi-layer insulated metal substrate operating with minimal thermal resistance spreads heat both downward and outward to ...

  • Hafler TRM6.1 - page 12

    – 3 – W ave Guide The wave guide is a proprietary axis-symmetrical form of horn mounted to the tweeter to increase efficiency . The wave guide improves the transition of sound waves (from planar to spherical) smoothly from the throat of the wave guide to the mouth. The unique shape and smooth surfaces improve the tweeter's off-axis frequen ...

  • Hafler TRM6.1 - page 13

    Power Switch Fr ont Panel View – 4 – Rear Panel V iew W oofer T weeter Rubber Pad Status LED W ave Guide Heatsink AC Line Input AC Line Fuse Balanced Input Unbalanced Input Sensitivity Bass Roll Off Bass Shelving T reble Shelving Input Switch ...

  • Hafler TRM6.1 - page 14

    LOCA TION The location of your reference monitors in addition to the acoustics of the listening room will influence the system frequency response. In the near field environment, our ears are more sensitive to direct sound rather than the reverberation of sound. Below are some recommendations for the initial set-up which may help you optimize perfor ...

  • Hafler TRM6.1 - page 15

    XLR Balanced Input Check output from source for proper signal polarity Pin 1 = GND Pin 2 = (+) Pin 3 = ( – ) INPUT FROM SOURCE XLR Unbalanced Input Connect ( – ) and GND (shield) terminals at both ends of cable to prevent unstable amplifier operation Pin 1 = GND Pin 2 = (+) Pin 3 = GND INPUT FROM SOURCE DETERMINING ACOUSTIC CENTER Finding the ? ...

  • Hafler TRM6.1 - page 16

    S CHEMA TIC D IAGRAM NOTES: Unless specified otherwise 1. All resistors in ohms. 2. All capacitors in microfarads. 3. Channel 1 only shown. – 7 – ...

  • Hafler TRM6.1 - page 17

    Qualified Service Personnel Only – 8 – ...

  • Hafler TRM6.1 - page 18

    S CHEMA TIC D IAGRAM NOTES: Unless specified otherwise 1. All resistors in ohms. 2. All capacitors in microfarads. 3. Channel 1 only shown. – 9 – ...

  • Hafler TRM6.1 - page 19

    Qualified Service Personnel Only – 10 – ...

  • Hafler TRM6.1 - page 20

    -1 1- S CHEMA TIC Diagram NOTES: Unless specified otherwise 1. All resistors in ohms. 2. All capacitors in microfarads. 3. Channel 1 only shown. Qualified Service Personnel Only ...

  • Hafler TRM6.1 - page 21

    PC B OARD L A YOUT Qualified Service Personnel Only – 12 – ...

  • Hafler TRM6.1 - page 22

    INPUT SENSITIVITY The Input Sensitivity adjustment is used to match the monitor with signal levels from a variety of mixing consoles. The Input Sensitivity uses DIP switches to match input levels over a 15dB range and are marked +1dB, – 2dB, – 5dB, – 8dB, and – 1 1dB. These numbers indicate the input in dBu required to produce an output of ...

  • Hafler TRM6.1 - page 23

    BASS SHEL VING Bass Shelving is used to match the low frequency response of the monitor to the acoustic environment. Bass Shelving uses DIP switches to control frequencies from 40Hz to 200Hz over an 8dB range and are marked +4dB, +2dB, – 2dB, and – 4dB. When all switches are in the OFF (left) position, the bass level is at 0dB. NOTE: When using ...

  • Hafler TRM6.1 - page 24

    POWER SWITCH The POWER switch is located on the front panel. The LED will illuminate GREEN, indicating the respective amplifiers are on. It is possible to leave the power switch in the ON position and switch the monitor remotely through a power distribution block or switched outlet. When doing so, make sure the switch is rated for the current requi ...

  • Hafler TRM6.1 - page 25

    – 16 – P ARTS L IST DESIGNA TOR V ALUE P ART # ALL RESIST ORS IN OHMS R1 RES 1.0K OHM 1/10W 1% RM/10-1001B R10 RES 47K OHM 1/10W 5% RM/10-473B R102 RES 6.8K OHM 1/4W 5% RM/4-682C R103 RES 6.8K OHM 1/4W 5% RM/4-682C R104 POT 5K 10% PIHER R V -502Q R105 RES 1.0K OHM 1/10W 1% RM/10-1001B R106 35.7K OHM 1/10 W A TT 1% RM/10-3572B R107 35.7K OHM 1/1 ...

  • Hafler TRM6.1 - page 26

    – 17 – R70 RES 280 OHM 1/10W 1% RM/10-2800B R71 RES 10 OHM 1/10W 5% RM/10-100B R72 RES 100 OHM 1/4W 5% RM/4-101C R73 RES 2.21K OHM 1/10W 1% RM/10-221 1B R74 RES 2.21K OHM 1/10W 1% RM/10-221 1B R75 RES 100K OHM 1/10W 5% RM/10-104B R76 619K OHM 1/10W 1% RM/10-6193B R78 RES 1M OHM 1/10W 5% RM/10-105B R79 RES 1M OHM 1/10W 5% RM/10-105B R8 POT 2K TR ...

  • Hafler TRM6.1 - page 27

    Components marked with this symbol are safety critical and should only be replaced with identical components. Los componentes marcados con el simbolo son imprescindibles para la protecci ó n del equipo, por lo cual que solo sean reemplazados por los mismos componentes. Les componsants marqu é s du symbole sont indis- pensables à la s é curit é ...

  • Hafler TRM6.1 - page 28

    TRM6.1 F UNCTIONAL B LOCK D IAGRAM – 19 – ...

  • Hafler TRM6.1 - page 29

    CIRCUIT OPERA TION trans • ana Implementation The transistor Q24 is configured to operate as a switch that controls the constant current source Q21 of the differ- ential amplifier Q27 and Q28. Switch Q24 is under the control of the thermal and turn-on circuits, and provides a Soft Start turn-on ramp according to the charging time of C70 through R ...

  • Hafler TRM6.1 - page 30

    The input signal is connected to the amplifier through the balanced XLR connector J1, or the unbalanced RCA connector J2. Balanced/unbal- anced switch DS1 will ground the inverting input buffer , allowing operation with an unbalanced signal on either connector . Input buffers U1A and U1B provide a stable input impedance, dominat- ed by R10 and R4. ...

  • Hafler TRM6.1 - page 31

    W oofer Crossover The input signal at U4A pin 1 connects to the 3200Hz 2nd order low-pass filter at U1 12B. Approximately 2dB of additional gain can be added to this stage by adjusting R136 against the divider resistor , R137. The next stage is a 30Hz – 60Hz switchable sub-sonic high-pass filter . This is followed by an adjustable low-frequency s ...

  • Hafler TRM6.1 - page 32

    – 23 – Clipping Indicator The CLIP indicators are driven by the comparator U5A and U5D. The voltage divider R56, R57, and R51, R61 establishes the reference voltage for the Clipping detector at pin 7 of U5A and pin 9 of U5D. Excessive drive sig- nal at pin 6 or pin 8 will trigger its comparator low and light the CLIP/THERMAL indicator red. On I ...

  • Hafler TRM6.1 - page 33

    – 24 – TWEETER REPLACEMENT Qualified Service Personnel Only 1. Remove (4) screws from wave guide using a 3/32" Allen W rench 2. Remove wave guide assembly from enclosure 3. Disconnect the LED harness (FIG. 1) 4. Disconnect the (2) speaker wires from the tweeter (FIG. 2) 5. Disconnect the (2) power switch wires (FIG. 3) 6. Unclip the tweete ...

  • Hafler TRM6.1 - page 34

    AMPLIFIER REPLACEMENT – 25 – Qualified Service Personnel Only 1. Remove (2) scr ews from back using a 3/32" Allen W rench (FIG. 5) 2. Disconnect PCB mounted LED harness (FIG. 6) 3. Disconnect PCB mounted tweeter speaker wires (FIG. 7) 4. Disconnect PCB mounted woofer speaker wires (FIG. 7) 5. Disconnect PCB mounted transformer primary wire ...

  • Hafler TRM6.1 - page 35

    S ER VICE P OLICY AND L IMITED W ARRANTY – 26 – Rockford Corporation (Hafler Division) offers a limited warranty on Hafler products on the following terms: • Length of W arranty 1 year on Reference Monitors • What is Covered This warranty applies only to products sold to the original owner and is non-transferable. This warranty only applies ...

  • Hafler TRM6.1 - page 36

    LIT 1 1382 1 1/00 E.W .R. HAFLER A DIVISION OF ROCKFORD CORPORA TION 546 SOUTH ROCKFORD DRIVE TEMPE, ARIZONA 85281 U.S.A. 1.866.GOHAFLER 480.967.3565 WWW .HAFLER.COM MADE IN THE USA This product is designed, developed and assembled in the USA by a dedicated group of American workers. The majority of the components used in the con- struction of this ...

Fabricante Hafler Categoría Computer Monitor

Los documentos del dispositivo Hafler TRM6.1 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Hafler
- manuales de instrucciones TRM6.1
- hojas de producto Hafler
- folletos informativos
- o etiquetas energéticas Hafler TRM6.1
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Hafler TRM6.1.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Hafler TRM6.1, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Hafler TRM6.1. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Hafler TRM6.1.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Hafler TRM6.1, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Hafler TRM6.1. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Hafler TRM6.1.

El manual de instrucciones completo de Hafler debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Hafler TRM6.1 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Hafler TRM6.1, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Hafler TRM6.1 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Hafler TRM6.1 - que deben facilitarnos los primeros pasos durante el uso de Hafler TRM6.1
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Hafler TRM6.1
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Hafler TRM6.1 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Hafler TRM6.1?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Hafler TRM6.1, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Hafler TRM6.1 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)