    Declaration of Conformity Application of Council Directive: 73/23/EEC (low voltage dir ective) Standard(s) to which Conformity is Declared: EN55103-1 EN55103-2 EN60065 (safety) Manufacturer ’ s Name: Hafler Manufacturer ’ s Address: 546 South Rockford Drive, T empe, Arizona 85281, U.S.A. Importer ’ s Name: ____________________________________ ...

  • Hafler TRM6.1 - page 3

    TRM6.1 Free Field Frequency Response 55Hz – 21kHz, ±2dB Peak Acoustic Output ≥ 1 19dB (per pair w/music @ 1m) T otal Harmonic Distortion (THD) <0.5%, 150Hz – 21kHz (90dB @ 1m on axis) High Frequency Driver 1" (25mm) V ifa Soft Dome Low Frequency Driver 6.5" (165mm) Polypropylene Cone/ Inverted Nitrile Rubber Surround Magneticall ...

  • Hafler TRM6.1 - page 4

    NOTICE - IMPOR T ANT SAFETY INFORMA TION 1. READ INSTRUCTIONS All the safety and operating instructions of your Hafler equipment should be read before power is applied to the equipment. 2. RET AIN OWNER'S MANUAL These safety and operating instructions should be retained for future reference. 3. HEED W ARNINGS All warnings on the equipment and ...

  • Hafler TRM6.1 - page 5

    – iii – ADVER TENCIA – INFORMACION DE SEGURIDAD IMPOR T ANTE 1. LEA LAS INSTRUCCIONES T odas las instrucciones de seguidad y operaci ó n de su equipo Hafler , deben ser le í das antes de que el equipo sea conectado dl é ctricamente. 2. CONSERVE EL MANUAL DEL PROPIET ARIO Estas instrucciones de seguridad y operaci ó n, deben ser conser- va ...

  • Hafler TRM6.1 - page 6

    – iv – A TTENTION: INFORMA TIONS IMPOR T ANTES DE S É CURIT É 1. LIRE LES INSTRUCTIONS Le mode d'emploi et les mesures de s é curit é de votre é quipement Hafler devraient ê tre consult é s avant sa mise en marche. 2. CONSERVER LE GUIDE DE L'UTILISA TEUR Le mode e'emploi et les mesures de s é curit é devraient ê tre con ...

  • Hafler TRM6.1 - page 7

    ACHTUNG – WICHTIGE SICHERHEITS – INFORMA TIONEN 1. INSTRUKTIONEN LESEN Alle Sicherheits- und Operationshinweise Ihres Hafler Equipments sollten vor der Inbetriebnahme gelesen werden. 2. BETRIEBSANLEITUNG AUFBEW AHREN Bewahren Sie die Bedienungsanleitung sorgf ä ltig auf, damit Sie in dieser auch in Zukunft nachschlagen k ö nnen. 3. W ARNUNGEN ...

  • Hafler TRM6.1 - page 8

    – vi – NOT ARE – IMPOR T ANTI INFORMAZIONI SULLA SICUREZZA 1. LEGGETE LE ISTRUZIONI T utte le istruzioni riguardanti la sicurezza ed il funzionamento devono essere lette prima di applicare tensione all'apparato. 2. CONSERV A TE IL MANUALE Queste istruzioni riguardanti la sicurezza ed il funzionamento devono essere conservate come riferim ...

  • Hafler TRM6.1 - page 9

    T ABLE OF C ONTENTS PERFORMANCE SPECIFICA TIONS ........................................................................................................................i Frequency Response Graph Energy T ime Curve Graph Horizontal Polar Response Graph Dimensions SAFETY PRECAUTIONS .................................................................... ...

  • Hafler TRM6.1 - page 10

    I NTRODUCTION – 1 – Thank you and congratulations on your purchase of the HAFLER TRM6.1 reference monitor , the world's finest brand in professional audio equipment. The TRM6.1 ( T rans • ana R eference M onitor) is a bi-amplified, two-way near field monitor offering unmatched quality and performance in a truly professional grade product ...

  • Hafler TRM6.1 - page 11

    Amplifie – 2 – MEHSA ( M aximum E fficiency H eat S ink A pplication) MEHSA is a proprietary process that yields up to 5 times better heat transfer than traditional FET mounting techniques using the exact same components. A multi-layer insulated metal substrate operating with minimal thermal resistance spreads heat both downward and outward to ...

  • Hafler TRM6.1 - page 12

    – 3 – W ave Guide The wave guide is a proprietary axis-symmetrical form of horn mounted to the tweeter to increase efficiency . The wave guide improves the transition of sound waves (from planar to spherical) smoothly from the throat of the wave guide to the mouth. The unique shape and smooth surfaces improve the tweeter's off-axis frequen ...

  • Hafler TRM6.1 - page 13

    Power Switch Fr ont Panel View – 4 – Rear Panel V iew W oofer T weeter Rubber Pad Status LED W ave Guide Heatsink AC Line Input AC Line Fuse Balanced Input Unbalanced Input Sensitivity Bass Roll Off Bass Shelving T reble Shelving Input Switch ...

  • Hafler TRM6.1 - page 14

    LOCA TION The location of your reference monitors in addition to the acoustics of the listening room will influence the system frequency response. In the near field environment, our ears are more sensitive to direct sound rather than the reverberation of sound. Below are some recommendations for the initial set-up which may help you optimize perfor ...

  • Hafler TRM6.1 - page 15

    XLR Balanced Input Check output from source for proper signal polarity Pin 1 = GND Pin 2 = (+) Pin 3 = ( – ) INPUT FROM SOURCE XLR Unbalanced Input Connect ( – ) and GND (shield) terminals at both ends of cable to prevent unstable amplifier operation Pin 1 = GND Pin 2 = (+) Pin 3 = GND INPUT FROM SOURCE DETERMINING ACOUSTIC CENTER Finding the ? ...

  • Hafler TRM6.1 - page 16

    S CHEMA TIC D IAGRAM NOTES: Unless specified otherwise 1. All resistors in ohms. 2. All capacitors in microfarads. 3. Channel 1 only shown. – 7 – ...

  • Hafler TRM6.1 - page 17

    Qualified Service Personnel Only – 8 – ...

  • Hafler TRM6.1 - page 18

    S CHEMA TIC D IAGRAM NOTES: Unless specified otherwise 1. All resistors in ohms. 2. All capacitors in microfarads. 3. Channel 1 only shown. – 9 – ...

  • Hafler TRM6.1 - page 19

    Qualified Service Personnel Only – 10 – ...

  • Hafler TRM6.1 - page 20

    -1 1- S CHEMA TIC Diagram NOTES: Unless specified otherwise 1. All resistors in ohms. 2. All capacitors in microfarads. 3. Channel 1 only shown. Qualified Service Personnel Only ...

  • Hafler TRM6.1 - page 21

    PC B OARD L A YOUT Qualified Service Personnel Only – 12 – ...

  • Hafler TRM6.1 - page 22

    INPUT SENSITIVITY The Input Sensitivity adjustment is used to match the monitor with signal levels from a variety of mixing consoles. The Input Sensitivity uses DIP switches to match input levels over a 15dB range and are marked +1dB, – 2dB, – 5dB, – 8dB, and – 1 1dB. These numbers indicate the input in dBu required to produce an output of ...

  • Hafler TRM6.1 - page 23

    BASS SHEL VING Bass Shelving is used to match the low frequency response of the monitor to the acoustic environment. Bass Shelving uses DIP switches to control frequencies from 40Hz to 200Hz over an 8dB range and are marked +4dB, +2dB, – 2dB, and – 4dB. When all switches are in the OFF (left) position, the bass level is at 0dB. NOTE: When using ...

  • Hafler TRM6.1 - page 24

    POWER SWITCH The POWER switch is located on the front panel. The LED will illuminate GREEN, indicating the respective amplifiers are on. It is possible to leave the power switch in the ON position and switch the monitor remotely through a power distribution block or switched outlet. When doing so, make sure the switch is rated for the current requi ...

  • Hafler TRM6.1 - page 25

    – 16 – P ARTS L IST DESIGNA TOR V ALUE P ART # ALL RESIST ORS IN OHMS R1 RES 1.0K OHM 1/10W 1% RM/10-1001B R10 RES 47K OHM 1/10W 5% RM/10-473B R102 RES 6.8K OHM 1/4W 5% RM/4-682C R103 RES 6.8K OHM 1/4W 5% RM/4-682C R104 POT 5K 10% PIHER R V -502Q R105 RES 1.0K OHM 1/10W 1% RM/10-1001B R106 35.7K OHM 1/10 W A TT 1% RM/10-3572B R107 35.7K OHM 1/1 ...

  • Hafler TRM6.1 - page 26

    – 17 – R70 RES 280 OHM 1/10W 1% RM/10-2800B R71 RES 10 OHM 1/10W 5% RM/10-100B R72 RES 100 OHM 1/4W 5% RM/4-101C R73 RES 2.21K OHM 1/10W 1% RM/10-221 1B R74 RES 2.21K OHM 1/10W 1% RM/10-221 1B R75 RES 100K OHM 1/10W 5% RM/10-104B R76 619K OHM 1/10W 1% RM/10-6193B R78 RES 1M OHM 1/10W 5% RM/10-105B R79 RES 1M OHM 1/10W 5% RM/10-105B R8 POT 2K TR ...

  • Hafler TRM6.1 - page 27

    Components marked with this symbol are safety critical and should only be replaced with identical components. Los componentes marcados con el simbolo son imprescindibles para la protecci ó n del equipo, por lo cual que solo sean reemplazados por los mismos componentes. Les componsants marqu é s du symbole sont indis- pensables à la s é curit é ...

  • Hafler TRM6.1 - page 28

    TRM6.1 F UNCTIONAL B LOCK D IAGRAM – 19 – ...

  • Hafler TRM6.1 - page 29

    CIRCUIT OPERA TION trans • ana Implementation The transistor Q24 is configured to operate as a switch that controls the constant current source Q21 of the differ- ential amplifier Q27 and Q28. Switch Q24 is under the control of the thermal and turn-on circuits, and provides a Soft Start turn-on ramp according to the charging time of C70 through R ...

  • Hafler TRM6.1 - page 30

    The input signal is connected to the amplifier through the balanced XLR connector J1, or the unbalanced RCA connector J2. Balanced/unbal- anced switch DS1 will ground the inverting input buffer , allowing operation with an unbalanced signal on either connector . Input buffers U1A and U1B provide a stable input impedance, dominat- ed by R10 and R4. ...

  • Hafler TRM6.1 - page 31

    W oofer Crossover The input signal at U4A pin 1 connects to the 3200Hz 2nd order low-pass filter at U1 12B. Approximately 2dB of additional gain can be added to this stage by adjusting R136 against the divider resistor , R137. The next stage is a 30Hz – 60Hz switchable sub-sonic high-pass filter . This is followed by an adjustable low-frequency s ...

  • Hafler TRM6.1 - page 32

    – 23 – Clipping Indicator The CLIP indicators are driven by the comparator U5A and U5D. The voltage divider R56, R57, and R51, R61 establishes the reference voltage for the Clipping detector at pin 7 of U5A and pin 9 of U5D. Excessive drive sig- nal at pin 6 or pin 8 will trigger its comparator low and light the CLIP/THERMAL indicator red. On I ...

  • Hafler TRM6.1 - page 33

    – 24 – TWEETER REPLACEMENT Qualified Service Personnel Only 1. Remove (4) screws from wave guide using a 3/32" Allen W rench 2. Remove wave guide assembly from enclosure 3. Disconnect the LED harness (FIG. 1) 4. Disconnect the (2) speaker wires from the tweeter (FIG. 2) 5. Disconnect the (2) power switch wires (FIG. 3) 6. Unclip the tweete ...

  • Hafler TRM6.1 - page 34

    AMPLIFIER REPLACEMENT – 25 – Qualified Service Personnel Only 1. Remove (2) scr ews from back using a 3/32" Allen W rench (FIG. 5) 2. Disconnect PCB mounted LED harness (FIG. 6) 3. Disconnect PCB mounted tweeter speaker wires (FIG. 7) 4. Disconnect PCB mounted woofer speaker wires (FIG. 7) 5. Disconnect PCB mounted transformer primary wire ...

  • Hafler TRM6.1 - page 35

    S ER VICE P OLICY AND L IMITED W ARRANTY – 26 – Rockford Corporation (Hafler Division) offers a limited warranty on Hafler products on the following terms: • Length of W arranty 1 year on Reference Monitors • What is Covered This warranty applies only to products sold to the original owner and is non-transferable. This warranty only applies ...

  • Hafler TRM6.1 - page 36

    LIT 1 1382 1 1/00 E.W .R. HAFLER A DIVISION OF ROCKFORD CORPORA TION 546 SOUTH ROCKFORD DRIVE TEMPE, ARIZONA 85281 U.S.A. 1.866.GOHAFLER 480.967.3565 WWW .HAFLER.COM MADE IN THE USA This product is designed, developed and assembled in the USA by a dedicated group of American workers. The majority of the components used in the con- struction of this ...

Fabbricante Hafler Categoria Computer Monitor

I documenti che otteniamo dal fabbricante del dispositivoHafler TRM6.1 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Hafler
- manuali per l’uso TRM6.1
- schede prodotto Hafler
- opuscoli
- o etichette energetiche Hafler TRM6.1
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Hafler TRM6.1.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Hafler TRM6.1, manuali di manutenzione, brevi manuali o manuali utente Hafler TRM6.1. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Hafler TRM6.1.

Manuali per l’uso simili

Manuale completo del dispositivo Hafler TRM6.1, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Hafler TRM6.1 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Hafler TRM6.1.

Il manuale per l’uso completo Hafler, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Hafler TRM6.1 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Hafler TRM6.1, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Hafler TRM6.1 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Hafler TRM6.1 - che ci dovrebbe aiutare nei primi passi durante l'uso Hafler TRM6.1
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Hafler TRM6.1
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Hafler TRM6.1 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Hafler TRM6.1?

Utilizza il modulo sottostante

Se non hai risolto il problema con Hafler TRM6.1 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Hafler TRM6.1 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)