/Chino FMSS Case-fr ont Self Ser vice Re v .0301 Installation & Operation Manual FMSS Case-fr ont Self Ser vice Refrigerated Mer chandiser p/n IGSS-FMSS-0301 INST ALLA TION & O P E R A T I ON GUIDE ...
-
hussman IGSS-FMSS-0301 - page 2
IGSS-FMSS-0301 2 /Chino A publication of Hussmann ® Chino 13770 Ramona Aven ue • Chino , California 91710 (909) 628-8942 F AX (909) 590-4910 (800) 395-9229 K eep this booklet with the case at all times for futur e r efer ence. THIS BOOKLET CONT AINS INFORMA TION ON: FMSS-Remote The FMSS is a single-deck, refrigerated, self-ser vice mer - chandis ...
-
hussman IGSS-FMSS-0301 - page 3
Rev.0 301 3 Cut & Plan Vie ws F a n FMSS Remote Self-Service Shown with Optional Special Height Scale = 1" *24" *26" *Dimensions adjust at these points to match service case height 13 1 / 2 " 12 1 / 4 " 6 1 / 8 " *10 1 / 2 " 16" FMSS Fr ont-Mount Self-Service case. Can be ordered to mount in front of ANY ...
-
hussman IGSS-FMSS-0301 - page 4
IGSS-FMSS-0301 4 LOCA TION The refrigerated mer chandisers ha ve been designed f or use only in air conditioned stor es wher e temperatur e and humidity ar e maintained at or below 75°F and 55% r ela- tive humidity . DO NO T allow air conditioning, electric fans, ov ens, open doors or windows (etc.) to cr eate air cur - r ents ar ound the merchand ...
-
hussman IGSS-FMSS-0301 - page 5
Rev.0 301 5 WASTE OUTLET AND P-TRAP The waste outlet is located at the left hand end of these fixtures allo wing drip piping to be run under the fixtur e lengthwise. A 1" P-trap and thr eaded adapter ar e supplied with each fixture. The P-trap must be installed to pr e vent air leakage and insect entrance into the fixtur e. INST ALLING CONDENS ...
-
hussman IGSS-FMSS-0301 - page 6
IGSS-FMSS-0301 6 Refrigeration REFRIGERANT TYPE The standard r efrigerant will be R-404 unless otherwise specified on the customer order . Check the serial plate on the case for information. Piping for mor e than one case on a condensing unit is run undergr ound with either common suction and liquid lines fr om the machine r oom or individual sucti ...
-
hussman IGSS-FMSS-0301 - page 7
Rev.0 301 7 WIRING COLOR CODE GREEN GROUND PURPLE ANTI-SWEA T ORANGE LIGHTS YELLOW RECEPT ACLE RED / BLACK T -ST A T /SOLENOID 230V BLACK / WHITE T - S TAT / S O L E N O I D 115V BRO WN F AN MOT ORS CASE MUST BE GROUNDED NOTE: Refer to label affixed to case to determine the actual configuration as checked in the “TYPE INSTALLED” boxes. Electric ...
-
hussman IGSS-FMSS-0301 - page 8
IGSS-FMSS-0301 8 Wiring Diagram DATE: PROJECT TITLE: DW G #: DRAWN BY: PRODUC TION ORDER #: DRAWING TITLE: DATE: REVISIONS: #: DESCR IPTION: CHECKED BY: BY: FILE LOCATION : ADRIAN E. CR ISCI AEC PAGE OF HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 90- 910 LIC.#: 6 06 1 2 3 11 07/29/02 H:WIRESCHEMATICSNE W- WIRING FMSS CASES W1 ...
-
hussman IGSS-FMSS-0301 - page 9
Rev.0 301 9 DATE: PROJECT TITLE: DW G #: DRAWN BY: PRODUC TION ORDER #: DRAWING TITLE: DATE: REVISIONS: #: DESCR IPTION: CHECKED BY: BY: FILE LOCATION : ADRIAN E. CR ISCI AEC PAGE OF HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 590-4910 L IC.#: 644406 1 2 3 11 07/29/02 H:WIRESCHEMATICSNE W- WIRING FMSS CASES W1400001 6' C ...
-
hussman IGSS-FMSS-0301 - page 10
IGSS-FMSS-0301 10 DATE: PROJECT TITLE: DW G #: DRAWN BY: PRODUC TION ORDER #: DRAWING TITLE: DATE: REVISIONS: #: DESCR IPTION: CHECKED BY: BY: FILE LOCATION : ADRIAN E. CR ISCI AEC PAGE OF HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 590-4910 L IC.#: 644406 1 2 3 11 07/29/02 H:WIRESCHEMATICSNE W- WIRING FMSS CASES W1400002 8&a ...
-
hussman IGSS-FMSS-0301 - page 11
Rev.0 301 11 DATE: PROJECT TITLE: DW G #: DRAWN BY: PRODUC TION ORDER #: DRAWING TITLE: DATE: REVISIONS: #: DESCR IPTION: CHECKED BY: BY: FILE LOCATION : ADRIAN E. CR ISCI AEC PAGE OF HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 590-4910 L IC.#: 644406 1 2 3 11 07/29/02 H:WIRESCHEMATICSNE W- WIRING FMSS CASES W1400003 10' ...
-
hussman IGSS-FMSS-0301 - page 12
IGSS-FMSS-0301 12 DATE: PROJECT TITLE: DW G #: DRAWN BY: PRODUC TION ORDER #: DRAWING TITLE: DATE: REVISIONS: #: DESCR IPTION: CHECKED BY: BY: FILE LOCATION : ADRIAN E. CR ISCI AEC PAGE OF HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 590-4910 L IC.#: 644406 1 2 3 11 07/29/02 H:WIRESCHEMATICSNE W- WIRING FMSS CASES W1400004 12& ...
-
hussman IGSS-FMSS-0301 - page 13
Rev.0 301 13 User Information STOCKING Improper temperatur e and lighting will cause serious prod- uct loss. Discoloration, deh ydration and spoilage can be contr olled with pr oper use of the equipment and handling of pr oduct. Pr oduct temperature should al wa ys be main- tained at a constant and pr oper temperatur e. This means that fr om the ti ...
-
hussman IGSS-FMSS-0301 - page 14
IGSS-FMSS-0301 14 Soap and hot w ater are not enough to kill this bacteria. A sanitizing solution must be included with each c leaning pro- cess to eliminate this bacteria. 1. Scrub thor oughly , cleaning all surfaces, with soap and hot water . 2. Rinse with hot water , but do not flood. 3. Apply the sanitizing solution accor ding to Hussmann’ s ...
-
hussman IGSS-FMSS-0301 - page 15
Rev.0 301 15 Specifications FMSS Medium T emp TEMPERATURE DISCHG. TYPE & FAN SIZE DEFROST Max 115 V. ELECTRICAL CIRCUITS SELF CONTAINED BTU AVG AIR T-STAT/ MAKE & FREQ. Low Pressure REQ’D EVAP PROD DISC VELOC CUT IN EVAP. NUMBER & STD. Control & PER FT. TMP TMP TMP @FPM SETTINGS COIL OF MOTORS DURATION FANS Warmers LIGHTS Settings ...
-
hussman IGSS-FMSS-0301 - page 16
IGSS-FMSS-0301 16 APPENDIX A. – Temperature Guidlines The refrigerators should be operated according to Hussmann’s published engineering specifications for entering air temperatures for specific equipment applications. Table 1 shows the typical temperature of the air entering the food zone one hour before the start of defrost and one hour after ...
-
hussman IGSS-FMSS-0301 - page 17
Rev.0 301 17 only in Fahrenheit shall be accurate to 2°F. The thermometer should be checked for proper calibration. (It should read 32°F when the stem is immersed in an ice water bath). b) LOCATION – The probe or sensing element of the thermometer should be located in the airstream where the air first enters the display or storage area, and not ...
-
hussman IGSS-FMSS-0301 - page 18
IGSS-FMSS-0301 18 ...
-
hussman IGSS-FMSS-0301 - page 19
Rev.0 301 19 Limited W arranty This warranty is made to the original user at the original installation site and is not transf erable . Hussmann merchandisers ar e war ranted to be free fr om def ect in material and workmanship under normal use and ser vice for a period of one (1) y ear fr om the date of original installation (not to exceed fifteen ...
-
hussman IGSS-FMSS-0301 - page 20
IGSS-FMSS-0301 20 The MODEL NAME and SERIAL NUMBER is required in or der to provide y ou with the correct parts and information for y our particular unit. They can be found on a small metal plate on the unit. Please note them below for futur e refer ence. MODEL: SERIAL NUMBER: /Chino Additional copies of this publication ma y be obtained b y contac ...
¿Tienes una pregunta acerca de hussman IGSS-FMSS-0301?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con hussman IGSS-FMSS-0301, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con hussman IGSS-FMSS-0301 probablemente compartirá una forma de solucionarlo.