    OPERA TING & SER VICE MANU AL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 10060.0000G 8/00 ©1984 Bunn-O-Matic Corporation BU N N ® U3 U3A ...

  • Bunn U3 U3A - page 2

    Page 2 INTRODUCTION This brewer will brew a three gallon batch of coffee into each reservoir (one at a time). Each reservoir has its own dispensing faucet(s).The brewer also has a hot water faucet(s) for allied beverage use. It is only for indoor use on a sturdy counter. W ARRANTY Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured ...

  • Bunn U3 U3A - page 3

    Page 3 ...

  • Bunn U3 U3A - page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. U333 & U3833 requires 3-wire, grounded service rated 240 volt ac, 35 amp or 440 volts ac, 30 amp for U333,three phase, 60 Hz or 380 volts ac, 30 amp for U3833, three phase, 50 Hz. Proceed as follows: U3 & U38 req ...

  • Bunn U3 U3A - page 5

    Page 5 INITIAL SETUP CAUTION - The brewer must be disconnected from the power source throughout the initial setup, except when specified in the instructions. IMPORTANT: Brewer must be level and installed on a sturdy structure. Electrician's and Plumber's Instructions are provided. These instructions should be carefully followed before pro ...

  • Bunn U3 U3A - page 6

    Page 6 INITIAL SETUP (cont.) 6. Brewing cycles may be started whenever water temperature is correct. This condition is indicated by the dial thermometer on front of the brewer. Whenever the pointer is in the green, brewer is ready for brewing. The recommended brewing temperature is approximately 200 ° F (93 ° C). Water temperature may be increase ...

  • Bunn U3 U3A - page 7

    Page 7 COFFEE BREWING 1. Brewing cycles may be started whenever water temperature is correct. This condition is indicated by the dial thermometer on front of the brewer. Whenever the pointer is in the green, brewer is ready for brewing. 2. Insert Bunn ® filter in funnel and add desired amount of coffee. 3. Level the bed of coffee and place funnel ...

  • Bunn U3 U3A - page 8

    Page 8 PROBLEM Brew cycle will not start PROBABLE CAUSE 1. No water 2. No power or incorrect voltage to the brewer REMEDY Water lines and valves to the brewer must be open. (A1) Check the terminal block for 120 volts ac across the red and white terminals and the black and white terminal on three wire 102/ 208 volt or 120/240 volt models. (A2) Check ...

  • Bunn U3 U3A - page 9

    Page 9 TROUBLESHOOTING (cont.) PROBLEM Brew cycle will not start (cont) Brew cycle starts with brew lockout relay engaged. PROBABLE CAUSE 2. No power or incorrect voltage to the brewer (cont) 3. Water level below pump housing. (Water level in the hot water gauge glass should be approximately half full). 4. ON/OFF Switch 5. Start Switch 6. Relay 7. ...

  • Bunn U3 U3A - page 10

    Page 10 TROUBLESHOOTING (cont.) PROBLEM Tank not filling Water running out of the overflow PROBABLE CAUSE 1.ON/OFF Switch (This switch must be in the "ON" position for the refill circuit to operate. 2. No water 3. Solenoid Valve 4. Probe 5. Liquid Level Board 1.Brewer not level 2. Solenoid Valve 3. Liquid Level Board 4. Probe 5. Manual fi ...

  • Bunn U3 U3A - page 11

    Page 11 PROBABLE CAUSE 1. Limit Thermostat CAUTION - Do not eliminate or bypass limit thermostat. Use only Bunn-O-Matic replacement part #29329.1000 2. Control Thermostat 3. Tank Heater(s) 4. Contactor 1. Circuit Breaker 2. Tank Heater(s) 1. Timer 2. Start Switch 1. Timer 2. Solenoid Valve 3. Lime build-up in swing spout and pump tubing. 1. Filters ...

  • Bunn U3 U3A - page 12

    Page 12 TROUBLESHOOTING (cont.) PROBLEM Funnels overflow (cont.) Coffee reservoir overflows Brewer is making unusal noises PROBABLE CAUSE REMEDY 3. Pump - Flow Rate 4. Soft Water 1. Coffee reservoir not completely empty befor a brew cycle was started. 2. Timer 3. Pump - Flow Rate 1. Solenoid Valve 2. Plumbing lines 3. Water supply 4. Tank Heater(s) ...

  • Bunn U3 U3A - page 13

    Page 13 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service pe ...

  • Bunn U3 U3A - page 14

    Page 14 SERVICE (cont.) CIRCUIT BREAKER (120/208V and 120/240V Three Wire Models and 440V Four Wire Models) Location: The circuit breaker is located on the right rear of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the black wire from the main harness from the circuit breaker and the white wi ...

  • Bunn U3 U3A - page 15

    Page 15 ...

  • Bunn U3 U3A - page 16

    Page 16 RED to Left Tank Heater (T2) RED to Terminal Block(L2) BLK Thermal Fuse to Left Tank Heater BLK to left Tank Heater (L1) BLK to Right Tank Heater (T1) BLK to Terminal Block (L1) RED to Right Tank Heater (L2) WHI from Main Harness (120/208V,120/240V,380V Three Wire Models, 380V and 440V Four Wire Models) RED from Main Harness (208V, 240V Two ...

  • Bunn U3 U3A - page 17

    Page 17 SERVICE (cont.) CONTROL THERMOSTAT ...

  • Bunn U3 U3A - page 18

    Page 18 SERVICE (cont.) FUSE AND FUSE HOLDER (208V, 240V, 230V Two Wire Models and 380V Three Wire Models) Location: The fuse and fuse holder are located on the right rear of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Remove the cap and fuse from the fuse holder. 3. Remove fuse from the cap. 4. Check ...

  • Bunn U3 U3A - page 19

    Page 19 LIMIT THERMOSTAT SERVICE (cont.) ...

  • Bunn U3 U3A - page 20

    Page 20 8. Disconnect the brewer from the power source and remove the jumper wire from terminal 4. If voltage is present as described, liquid level board is operating properly, proceed to #9. If voltage is not present as described, replace the liquid level board. LIQUID LEVEL BOARD AND LEVEL PROBE ...

  • Bunn U3 U3A - page 21

    Page 21 SERVICE (cont.) LIQUID LEVEL BOARD AND LEVEL PROBE (cont.) T1 BLU to Solenoid Valve T2 BLK to ON/OFF Switch (All models except 230V-CE models) T3 WHI to Main Harness (120/208V, 120/240V, four wire 380V and 440V models) T3 WHI to Transformer (380V three wire models) T3 RED to Main Harness (208V, 240V single phase and three phase models) T3 B ...

  • Bunn U3 U3A - page 22

    Page 22 5. Disconnect the wires on the ON/OFF switch. 6. a) 120/208V, 120/240V, 208V, 240V, 380V and 440V Models - Check for continuity across the terminals on the rear of the switch with the switch in the "ON" (upper) position. Continuity must not be present when the switch is in the "OFF" (lower) position. b) 230V - CE Models ...

  • Bunn U3 U3A - page 23

    Page 23 SERVICE (cont.) PUMP ASSEMBLY ...

  • Bunn U3 U3A - page 24

    Page 24 RELAY (BREWERS W/BREW LOCKOUT) ...

  • Bunn U3 U3A - page 25

    Page 25 SERVICE (cont.) RELAY (BREWERS W/BREW LOCKOUT) 120/208V, 120/240V, 208V, 380V, 440V AND 240V MODELS PRIOR TO #U300004095 230V MODELS #U300004095 AND UP FIG.19 RELAY TERMINALS P1739 RED from Main Harness BLU from Brew Timer BLK to Control Thermostat BLU to Start Switch BLU from Brew Timer BLK from Main Harness RED to Control Thermostat BLU f ...

  • Bunn U3 U3A - page 26

    Page 26 SELECTOR SWITCH (HALF BATCH OPTION) FIG. 20 SELECTOR SWITCH (HALF BATCH) Location: The selector switch is located in the upper center of the switch mounting panel. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the wires from the switch terminals. 3. Check for continuity across the switch terminals with the s ...

  • Bunn U3 U3A - page 27

    Page 27 SERVICE (cont.) SOLENOID ...

  • Bunn U3 U3A - page 28

    Page 28 SERVICE (cont.) SOLENOID 6. Remove the tank inlet tube grommet and discard. 7. Install new tank inlet tube grommet. 8. Install new solenoid assembly. 9. Install liquid level board, shield and secure sole- noid assembly and shield to the component bracket with a #10-32 screw and flat washer.. 10. Install water inlet tube to connector on the ...

  • Bunn U3 U3A - page 29

    Page 29 START SWITCH (BREW) ...

  • Bunn U3 U3A - page 30

    Page 30 BLK to Contactor T1 (All Models Except 230V-CE Models) BLK (Thermal Fuse) to Contactor Top Left Ter- minal) (230V-CE Models) RED to Contactor T2 (All Models Except 230V-CE Models) RED (Thermal Fuse) to Contactor Top Right Termi- nal) (230V-CE Models) BLK to Contactor L1 (120/ 208V, 120/240 Three Wire Single Phase, 208V and 240V Two Wire, Si ...

  • Bunn U3 U3A - page 31

    Page 31 SERVICE (cont.) THERMAL FUSES (230V-CE MODELS ONLY) ...

  • Bunn U3 U3A - page 32

    Page 32 SERVICE (cont.) TIMER (Early Models)(cont.) 5. With a voltmeter, check the voltage across the sockets P1 and P2 (blue and white wires) of the female connector on the main harness when the "ON/OFF" switch is in the "ON" (upper) position and the start switch pressed. Connect the brewer to the power source. The indication m ...

  • Bunn U3 U3A - page 33

    Page 33 DIGITAL TIMER (Late Models) ...

  • Bunn U3 U3A - page 34

    Page 34 SERVICE (cont.) DIGITAL TIMER (Late Models) BLU/BLK wire from TL5 to P1 WHI/GRN wire from TL4 to (WHI) Pump WHI/BLU wire from TL3 to (BLK) Pump WHI wire from TL2 to P2 BLK wire from TL1 to P3 J2 - Three Pin connector from Half/Full Batch Switch P2037 FIG. 33 DIGITAL TIMER TERMINALS NOTE: All volume settings must be done with the sprayhead i ...

  • Bunn U3 U3A - page 35

    Page 35 BLK from Terminal Block SERVICE (cont.) TRANSFORMER (380V THREE WIRE MODELS ONLY) ...

  • Bunn U3 U3A - page 36

    Page 36 ...

  • Bunn U3 U3A - page 37

    Page 37 ...

  • Bunn U3 U3A - page 38

    Page 38 ...

  • Bunn U3 U3A - page 39

    Page 39 ...

  • Bunn U3 U3A - page 40

    Page 40 SCHEMA TIC WIRING DIAGRAM U3833 10060 080900 ...

  • Bunn U3 U3A - page 41

    Page 41 SCHEMA TIC WIRING DIGRAM U3833 10060 080900 ...

Fabricante Bunn Categoría Coffeemaker

Los documentos del dispositivo Bunn U3 U3A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bunn
- manuales de instrucciones U3 U3A
- hojas de producto Bunn
- folletos informativos
- o etiquetas energéticas Bunn U3 U3A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bunn U3 U3A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bunn U3 U3A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bunn U3 U3A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bunn U3 U3A.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bunn U3 U3A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bunn U3 U3A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bunn U3 U3A.

El manual de instrucciones completo de Bunn debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bunn U3 U3A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bunn U3 U3A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bunn U3 U3A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bunn U3 U3A - que deben facilitarnos los primeros pasos durante el uso de Bunn U3 U3A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bunn U3 U3A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Bunn U3 U3A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Bunn U3 U3A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bunn U3 U3A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bunn U3 U3A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)