    Owner’s Operator and Maintenance Manual DEALE R: This manual M UST be given to the user of th e product. USER: BEFORE using this product, read this manual an d save for future reference. For mo re inform ation reg arding In va ca re p ro du cts , pa rts, and services, please v isit www.inva care.com MA80 Series MA80 True Low Air Loss System MA85 ...

  • Invacare MA80 - page 2

    SPECIAL NOTES MA80 Series 2 Part No 1148138  WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any addition al instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you ...

  • Invacare MA80 - page 3

    TABL E OF CON TENT S Part No 1148138 3 MA80 Series TABLE OF CONTENT S SPE CI AL NOT ES ..... ...... ...... ...... ....... ...... ...... ...... ....... ...... ...... ...... ...... . 2 REGISTER YO UR PRODUCT ..... ..... ...... ...... ...... ...... ..... ...... ...... ........ .... 4 TYP ICA L P RO DUC T P ARAM ET ERS ...... ...... ...... ...... ..... ...

  • Invacare MA80 - page 4

    TABLE OF CONTENTS MA80 Series 4 Part No 1148138 TABLE OF CONTENT S Transferring Patient Fr om/To a Gurney ............ ........................... ........................... ...........................19 Transferring Patient Fr om/To a Wheelchair ....................... ........................... ........................... ......... 19 Preparing ...

  • Invacare MA80 - page 5

    TYPICAL PRODUCT PARAMETERS Part No 1148138 5 MA 80 Se rie s TYPICAL PRODUCT PARAMETERS Electric al Paramet ers Performanc e Paramete rs Mechanical P arameters MA80/MA85 INPUT VOLTAGE AC: 90 V INPUT FREQUEN CY: 60 H z CURRENT: 2 A MAXIMU M POWER CONSU MPTION: 150 ± 10 W CIRCUIT PROTECTION: Dual fused, 250 V, 5 A fast blow fuses MODE OF OPERATION: C ...

  • Invacare MA80 - page 6

    TYPICAL PRODUCT PARAMETERS MA80 Series 6 Part No 1148138 Environment al Paramet ers MA80/MA85 OPERATING CONDITIONS AMBIENT TEMPERA TURE: RELATIVE HUMIDITY: ATMOSPHERIC PR ESSURE: 50° - 104° F 30% - 75% Non-Condensing 70 - 106 kPa STORAGE AND SHIP PING CONDITIONS AMBIENT TEMPERA TURE: RELATIVE HUMIDITY: ATMOSPHERIC PR ESSURE: -40° - 158° F 10% - ...

  • Invacare MA80 - page 7

    LABEL LOCATION Part No 1148138 7 MA 80 Se rie s LABEL LOCAT ION DANGER-EXPLOSION HAZARD: DO NOT us e in the presence of flammable anesthetics. CAUTION: Eq uipment should be connected to a properly grounded receptacle (3-prong). Risk of Electrical shock. DO NOT remove back. Disconnect air hose before administering CPR. NOTE: This label is on the bac ...

  • Invacare MA80 - page 8

    SECTION 1—GENERAL GUIDELINES MA80 Series 8 Part No 1148138 SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the s afe operation and use of this product. Contraindications ALW AYS consult the patient’ s physi cian b efore using the MA80 and MA85 systems. Installation The MA80 and MA85 s ...

  • Invacare MA80 - page 9

    SECTION 1—GENERAL GUIDELINES Part No 1148138 9 MA 80 Se rie s Fire Hazard  DANGER Smoking DO NOT SMOKE while using this device. This system uses r oom air for circulation through the mattress. A cigarett e can burn a hole i n the bed surface and cause damage to the m attress. Also, p atient cl othing, bed sheets, etc. may be combustible and ca ...

  • Invacare MA80 - page 10

    SECTION 2—OPERATION MA80 Series 10 Part No 1148138 SECTION 2—OPERATION CAUTION The control unit and mattress on the MA80 series are designed to be used as a system. DO NOT replace mattresses or control units with other models or other brands. Otherwise, damage to the system m ay occur. Contact your supplier to get the correct replacement if nee ...

  • Invacare MA80 - page 11

    SECTION 2—OPERATION Part No 1148138 11 MA80 Se rie s FIGURE 2.1 Installing the Mattress Replacement System Installing the Side R ails  WARNING Patient entrapment with bed side rails may cause injury or death. Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment. Follow the manufacturer’s instructions. Monitor patie ...

  • Invacare MA80 - page 12

    SECTION 2—OPERATION MA80 Series 12 Part No 1148138 Connecting the Hose CAUTION Ensure that the hose connecting the control unit to the mattress i s routed such t hat it cannot be stepped on, kinked, squeezed or otherwise damaged. NOTE: For this pr ocedure, r efer to FIGURE 2.3. 1. Locate the hose at the foo t end of the mattress. 2. Locate the co ...

  • Invacare MA80 - page 13

    SECTION 2—OPERATION Part No 1148138 13 MA80 Se rie s Connecting the Power Cord  WARNING DO NOT alter plug to fit a non-conforming outlet. Instead, have an electrician install a properly grounded outlet. Failure to use the correct plug and outlet can result in a potential safety hazard. CAUTION Ensure that the power cord of the control unit is ...

  • Invacare MA80 - page 14

    SECTION 2—OPERATION MA80 Series 14 Part No 1148138 Using the Front Panel NOTE: For this pr ocedure, r efer to FIGURE 2.5. FIGURE 2.5 Using the Front Panel Power Butt on 1. T o turn the contro l uni t on or off, press and release the P ower butt on ( ). NOTE: Once the u nit is plugged in, an A MBER LED on t he contr ol unit is lit indic ating that ...

  • Invacare MA80 - page 15

    SECTION 2—OPERATION Part No 1148138 15 MA80 Se rie s Pulse Butto n (MA80) 1. Press the Pulse button ( ) to T urn on Pu lse mo de and select one of four Pulse Times - 1, 3, 5 or 10 minutes. NOTE: The pulse tim es are 1, 3, 5 or 10 minutes. The pul se times indicate the time between each low pulse . For example, i f 5 minutes is selected, all the a ...

  • Invacare MA80 - page 16

    SECTION 2—OPERATION MA80 Series 16 Part No 1148138 Static B utton 1. Press the Static button ( ) to select the static mode and maintain the mattress at constant pressure. NOTE: The Static LED is illumin ated GREEN. Firm/Soft Buttons 1. Select comfort pressure sett in gs by pressing Firm ( ) or Soft ( ) b uttons. • Soft Button - Pressing this bu ...

  • Invacare MA80 - page 17

    SECTION 2—OPERATION Part No 1148138 17 MA80 Se rie s 5. P erform one of the following: • Cancel - Press the Fowler button to exit Fowler T ransmitter Setup wi thout linking to a transmitter . • Sav e - W ait 60 seconds w ithout pressing a key . Max Inflate B utton 1. Press the Max Inflate button ( ) to select the max i nflate mode and inflate ...

  • Invacare MA80 - page 18

    SECTION 2—OPERATION MA80 Series 18 Part No 1148138 Powering Up the System NOTE: For this pr ocedure, r efer to FIGURE 2.5 on page 14. 1. T urn on the powe r to the system by pressing the P ow er button on the contro l uni t. NOTE: Once the button is released, a GREEN LED illuminates when the un it is on. Placing the Patient on the Ma ttress 1. Pr ...

  • Invacare MA80 - page 19

    SECTION 2—OPERATION Part No 1148138 19 MA80 Se rie s Transferring Patient From/To a Gurney  WARNING ALWAYS engage the wheel locks of the bed and the wheel locks of the gurney before transferring the patient between the bed and the gurney. 1. Engage the wheel locks of the bed. Refer to the owner ’ s manual provided w ith the bed. 2. Engage th ...

  • Invacare MA80 - page 20

    SECTION 2—OPERATION MA80 Series 20 Part No 1148138 FIGURE 2.6 Preparing for CPR Procedure Connector Cover Contro l Unit Connector Holes Hose Connector DETAIL “A” Control Unit DETAIL “B” ...

  • Invacare MA80 - page 21

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING Part No 1148138 21 MA80 Se rie s SECTION 3—MAIN TENANCE AND TROUBLESHOOTING Cleaning the System  WARNING Before cleaning or disassembling the MA80 series, check the underside of the mattress folds for sharp objects such as scissors, needles, etc. These objects should be removed and discarded before p ...

  • Invacare MA80 - page 22

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING MA80 Series 22 Part No 1148138 CAUT ION Laundry workers should always wash their hands before working with clean bedding. DO NOT overload the machine. DO NOT use chlorine bleach because it may damage the fabric coating. High air temperatures will damage the fabrics and void the Invacare warranty. i. Place ...

  • Invacare MA80 - page 23

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING Part No 1148138 23 MA80 Se rie s Changing the Filter NOTE: For this pr ocedure, r efer to FIGURE 3.1. Clean the filter ev ery 5 months or whenev er it is di rty . 1. Remov e the two screws s ecuring the filter cover to the back of the contro l unit. 2. Remov e the filter . 3. W ash the filter with water a ...

  • Invacare MA80 - page 24

    LIMITED WARRANTY PLEASE NO TE: TH E WAR RANTY B ELOW H AS BEEN DRAFTE D TO COMPLY W ITH FED ERAL LAW APPLICAB LE TO PR ODUC TS MANUFAC TURED AFTER JULY 4, 1975. This wa rrant y is e xtended o nly t o the or igin al pu rchaser who pur chases t his prod uct when new and unused from I nvacar e or a dealer. This warra nty i s not ext ended t o any o th ...

Fabricante Invacare Categoría Camping Equipment

Los documentos del dispositivo Invacare MA80 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Invacare
- manuales de instrucciones MA80
- hojas de producto Invacare
- folletos informativos
- o etiquetas energéticas Invacare MA80
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Invacare MA80.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Invacare MA80, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Invacare MA80. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Invacare MA80.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Invacare MA80, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Invacare MA80. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Invacare MA80.

El manual de instrucciones completo de Invacare debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Invacare MA80 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Invacare MA80, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Invacare MA80 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Invacare MA80 - que deben facilitarnos los primeros pasos durante el uso de Invacare MA80
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Invacare MA80
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Invacare MA80 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Invacare MA80?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Invacare MA80, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Invacare MA80 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)