Manuale per l’uso Invacare MA80

24 pagine 0.55 mb
Scarica

Vai alla pagina of 24

Summary
  • Invacare MA80 - page 1

    Owner’s Operator and Maintenance Manual DEALE R: This manual M UST be given to the user of th e product. USER: BEFORE using this product, read this manual an d save for future reference. For mo re inform ation reg arding In va ca re p ro du cts , pa rts, and services, please v isit www.inva care.com MA80 Series MA80 True Low Air Loss System MA85 ...

  • Invacare MA80 - page 2

    SPECIAL NOTES MA80 Series 2 Part No 1148138  WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any addition al instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you ...

  • Invacare MA80 - page 3

    TABL E OF CON TENT S Part No 1148138 3 MA80 Series TABLE OF CONTENT S SPE CI AL NOT ES ..... ...... ...... ...... ....... ...... ...... ...... ....... ...... ...... ...... ...... . 2 REGISTER YO UR PRODUCT ..... ..... ...... ...... ...... ...... ..... ...... ...... ........ .... 4 TYP ICA L P RO DUC T P ARAM ET ERS ...... ...... ...... ...... ..... ...

  • Invacare MA80 - page 4

    TABLE OF CONTENTS MA80 Series 4 Part No 1148138 TABLE OF CONTENT S Transferring Patient Fr om/To a Gurney ............ ........................... ........................... ...........................19 Transferring Patient Fr om/To a Wheelchair ....................... ........................... ........................... ......... 19 Preparing ...

  • Invacare MA80 - page 5

    TYPICAL PRODUCT PARAMETERS Part No 1148138 5 MA 80 Se rie s TYPICAL PRODUCT PARAMETERS Electric al Paramet ers Performanc e Paramete rs Mechanical P arameters MA80/MA85 INPUT VOLTAGE AC: 90 V INPUT FREQUEN CY: 60 H z CURRENT: 2 A MAXIMU M POWER CONSU MPTION: 150 ± 10 W CIRCUIT PROTECTION: Dual fused, 250 V, 5 A fast blow fuses MODE OF OPERATION: C ...

  • Invacare MA80 - page 6

    TYPICAL PRODUCT PARAMETERS MA80 Series 6 Part No 1148138 Environment al Paramet ers MA80/MA85 OPERATING CONDITIONS AMBIENT TEMPERA TURE: RELATIVE HUMIDITY: ATMOSPHERIC PR ESSURE: 50° - 104° F 30% - 75% Non-Condensing 70 - 106 kPa STORAGE AND SHIP PING CONDITIONS AMBIENT TEMPERA TURE: RELATIVE HUMIDITY: ATMOSPHERIC PR ESSURE: -40° - 158° F 10% - ...

  • Invacare MA80 - page 7

    LABEL LOCATION Part No 1148138 7 MA 80 Se rie s LABEL LOCAT ION DANGER-EXPLOSION HAZARD: DO NOT us e in the presence of flammable anesthetics. CAUTION: Eq uipment should be connected to a properly grounded receptacle (3-prong). Risk of Electrical shock. DO NOT remove back. Disconnect air hose before administering CPR. NOTE: This label is on the bac ...

  • Invacare MA80 - page 8

    SECTION 1—GENERAL GUIDELINES MA80 Series 8 Part No 1148138 SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the s afe operation and use of this product. Contraindications ALW AYS consult the patient’ s physi cian b efore using the MA80 and MA85 systems. Installation The MA80 and MA85 s ...

  • Invacare MA80 - page 9

    SECTION 1—GENERAL GUIDELINES Part No 1148138 9 MA 80 Se rie s Fire Hazard  DANGER Smoking DO NOT SMOKE while using this device. This system uses r oom air for circulation through the mattress. A cigarett e can burn a hole i n the bed surface and cause damage to the m attress. Also, p atient cl othing, bed sheets, etc. may be combustible and ca ...

  • Invacare MA80 - page 10

    SECTION 2—OPERATION MA80 Series 10 Part No 1148138 SECTION 2—OPERATION CAUTION The control unit and mattress on the MA80 series are designed to be used as a system. DO NOT replace mattresses or control units with other models or other brands. Otherwise, damage to the system m ay occur. Contact your supplier to get the correct replacement if nee ...

  • Invacare MA80 - page 11

    SECTION 2—OPERATION Part No 1148138 11 MA80 Se rie s FIGURE 2.1 Installing the Mattress Replacement System Installing the Side R ails  WARNING Patient entrapment with bed side rails may cause injury or death. Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment. Follow the manufacturer’s instructions. Monitor patie ...

  • Invacare MA80 - page 12

    SECTION 2—OPERATION MA80 Series 12 Part No 1148138 Connecting the Hose CAUTION Ensure that the hose connecting the control unit to the mattress i s routed such t hat it cannot be stepped on, kinked, squeezed or otherwise damaged. NOTE: For this pr ocedure, r efer to FIGURE 2.3. 1. Locate the hose at the foo t end of the mattress. 2. Locate the co ...

  • Invacare MA80 - page 13

    SECTION 2—OPERATION Part No 1148138 13 MA80 Se rie s Connecting the Power Cord  WARNING DO NOT alter plug to fit a non-conforming outlet. Instead, have an electrician install a properly grounded outlet. Failure to use the correct plug and outlet can result in a potential safety hazard. CAUTION Ensure that the power cord of the control unit is ...

  • Invacare MA80 - page 14

    SECTION 2—OPERATION MA80 Series 14 Part No 1148138 Using the Front Panel NOTE: For this pr ocedure, r efer to FIGURE 2.5. FIGURE 2.5 Using the Front Panel Power Butt on 1. T o turn the contro l uni t on or off, press and release the P ower butt on ( ). NOTE: Once the u nit is plugged in, an A MBER LED on t he contr ol unit is lit indic ating that ...

  • Invacare MA80 - page 15

    SECTION 2—OPERATION Part No 1148138 15 MA80 Se rie s Pulse Butto n (MA80) 1. Press the Pulse button ( ) to T urn on Pu lse mo de and select one of four Pulse Times - 1, 3, 5 or 10 minutes. NOTE: The pulse tim es are 1, 3, 5 or 10 minutes. The pul se times indicate the time between each low pulse . For example, i f 5 minutes is selected, all the a ...

  • Invacare MA80 - page 16

    SECTION 2—OPERATION MA80 Series 16 Part No 1148138 Static B utton 1. Press the Static button ( ) to select the static mode and maintain the mattress at constant pressure. NOTE: The Static LED is illumin ated GREEN. Firm/Soft Buttons 1. Select comfort pressure sett in gs by pressing Firm ( ) or Soft ( ) b uttons. • Soft Button - Pressing this bu ...

  • Invacare MA80 - page 17

    SECTION 2—OPERATION Part No 1148138 17 MA80 Se rie s 5. P erform one of the following: • Cancel - Press the Fowler button to exit Fowler T ransmitter Setup wi thout linking to a transmitter . • Sav e - W ait 60 seconds w ithout pressing a key . Max Inflate B utton 1. Press the Max Inflate button ( ) to select the max i nflate mode and inflate ...

  • Invacare MA80 - page 18

    SECTION 2—OPERATION MA80 Series 18 Part No 1148138 Powering Up the System NOTE: For this pr ocedure, r efer to FIGURE 2.5 on page 14. 1. T urn on the powe r to the system by pressing the P ow er button on the contro l uni t. NOTE: Once the button is released, a GREEN LED illuminates when the un it is on. Placing the Patient on the Ma ttress 1. Pr ...

  • Invacare MA80 - page 19

    SECTION 2—OPERATION Part No 1148138 19 MA80 Se rie s Transferring Patient From/To a Gurney  WARNING ALWAYS engage the wheel locks of the bed and the wheel locks of the gurney before transferring the patient between the bed and the gurney. 1. Engage the wheel locks of the bed. Refer to the owner ’ s manual provided w ith the bed. 2. Engage th ...

  • Invacare MA80 - page 20

    SECTION 2—OPERATION MA80 Series 20 Part No 1148138 FIGURE 2.6 Preparing for CPR Procedure Connector Cover Contro l Unit Connector Holes Hose Connector DETAIL “A” Control Unit DETAIL “B” ...

  • Invacare MA80 - page 21

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING Part No 1148138 21 MA80 Se rie s SECTION 3—MAIN TENANCE AND TROUBLESHOOTING Cleaning the System  WARNING Before cleaning or disassembling the MA80 series, check the underside of the mattress folds for sharp objects such as scissors, needles, etc. These objects should be removed and discarded before p ...

  • Invacare MA80 - page 22

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING MA80 Series 22 Part No 1148138 CAUT ION Laundry workers should always wash their hands before working with clean bedding. DO NOT overload the machine. DO NOT use chlorine bleach because it may damage the fabric coating. High air temperatures will damage the fabrics and void the Invacare warranty. i. Place ...

  • Invacare MA80 - page 23

    SECTION 3—MAINTENANCE AND TROUBLESHOOTING Part No 1148138 23 MA80 Se rie s Changing the Filter NOTE: For this pr ocedure, r efer to FIGURE 3.1. Clean the filter ev ery 5 months or whenev er it is di rty . 1. Remov e the two screws s ecuring the filter cover to the back of the contro l unit. 2. Remov e the filter . 3. W ash the filter with water a ...

  • Invacare MA80 - page 24

    LIMITED WARRANTY PLEASE NO TE: TH E WAR RANTY B ELOW H AS BEEN DRAFTE D TO COMPLY W ITH FED ERAL LAW APPLICAB LE TO PR ODUC TS MANUFAC TURED AFTER JULY 4, 1975. This wa rrant y is e xtended o nly t o the or igin al pu rchaser who pur chases t his prod uct when new and unused from I nvacar e or a dealer. This warra nty i s not ext ended t o any o th ...

Fabbricante Invacare Categoria Camping Equipment

I documenti che otteniamo dal fabbricante del dispositivoInvacare MA80 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Invacare
- manuali per l’uso MA80
- schede prodotto Invacare
- opuscoli
- o etichette energetiche Invacare MA80
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Invacare MA80.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Invacare MA80, manuali di manutenzione, brevi manuali o manuali utente Invacare MA80. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Invacare MA80.

Manuali per l’uso simili

Manuale completo del dispositivo Invacare MA80, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Invacare MA80 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Invacare MA80.

Il manuale per l’uso completo Invacare, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Invacare MA80 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Invacare MA80, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Invacare MA80 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Invacare MA80 - che ci dovrebbe aiutare nei primi passi durante l'uso Invacare MA80
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Invacare MA80
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Invacare MA80 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Invacare MA80?

Utilizza il modulo sottostante

Se non hai risolto il problema con Invacare MA80 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Invacare MA80 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)