  • Myson 1370064 - page 1

    Installation, Operating, Maintenance and After Sales Manual. Product Serial Number: Please leave this manual with the end user . Part Number: 1370064 Issue 2 heating through innovation. SLIM-LINE RC 01.07.2009 ISSUE 2 22369 Slimline RC Manual:Layout 1 10/11/09 16:02 Page 2 ...

  • Myson 1370064 - page 2

    1.0 General Information 03 2.0 Heating System Design 03 3.0 Unit Selection/Sizing 03 4.0 Location 03 5.0 Preparation 04 6.0 Fixing 04 7.0 W ater Connections 05 8.0 Electrical Connection 06 9.0 Commissioning Procedur e 07 10.0 T echnical Data 08 11.0 Operating Instructions 09 12.0 T roubleshooting 10 13.0 Maintenance 11 Contents 22369 Slimline RC Ma ...

  • Myson 1370064 - page 3

    03 SLIM-LINE RC 1.0 General Information 2.0 Heating System Design G This MYSON SLIM-LINE RC fan convector is designed for wall mounted installation with a minimum installation height of 150mm to the underside of the unit. G The SLIM-LINE RC should only be used on closed circulation, two pipe, pump assisted central heating systems. G The SLIM-LINE R ...

  • Myson 1370064 - page 4

    04 SLIM-LINE RC 5.0 Preparation Before pr oceeding with the installation, unpack the carton contents and check against the checklist below: 1. SLIM-LINE RC unit. 2. 15mm isolating valves (1 pair). 3. Instruction manual. 4. W arranty card. 5. Fixing kit (rubber mounts and cable gland). 6. Remote control handset. 6.0 Fixing G Using the fixing dimensi ...

  • Myson 1370064 - page 5

    05 SLIM-LINE RC 7.0 W ater Connections G Connect unit to system flow and return pipes using the two 15mm isolating valves (see fig. 2). Note: T o ensure ef fective venting of the heat exchanger the flow pipe should be connected to the bottom connection of the heat exchanger . Note: For SLIM-LINE RC installations pipe-work must not be routed dir ect ...

  • Myson 1370064 - page 6

    06 SLIM-LINE RC G This unit is supplied with factory fitted test leads. Remove these and discard. G A fused electrical spur with a maximum 3A fuse and a switch having 3mm separation on all poles must be provided in an easily accessible position adjacent to the unit. G Electrical cable entry to the unit should be made through the underside of the un ...

  • Myson 1370064 - page 7

    07 SLIM-LINE RC 9.0 Commissioning Procedur e G Fill and vent the system. G Open both valves fully and vent air from the heat exchanger by unscrewing the air bleed valve situated above the valves in the angled top of the chassis. G Check for leaks at pipe connections. G Refit the outer case and secure using the 2 fixing scr ews. G Switch on electric ...

  • Myson 1370064 - page 8

    T ested in accordance with BS 4856 Part 1. Flow rate 340 ltr/h (75 gal/h). Flow Rate Correction Factors: 455 ltr/h (100 gal/h) multiply by 1.03 227 ltr/h (50 gal/h) multiply by 0.96 113 ltr/h (25 gal/h) multiply by 0.85 Electrical supply 230V 50Hz T est pressur e 20bar (1MPa) Max working pressur e 10bar (1MPa) W ater connections 15mm compression Un ...

  • Myson 1370064 - page 9

    09 SLIM-LINE RC 11.0 Operating Instructions Description This SLIM-LINE RC unit is fitted with a control system that provides either automatic or manual contr ol of the unit. In automatic mode the desired temperatur e set point is selected and the unit will adjust the fan speed according to the dif ference between the actual room temperatur e and th ...

  • Myson 1370064 - page 10

    Manual Manual mode can be used for air circulation without heat or for manual control of the heating function. Use ‘+’ to scroll Selected fan speed beyond 35°C displayed Or use ‘-’ to scroll below 15°C Scrolling back out of manual using the ‘+’ or ‘–’ button will r evert the unit back to last temperature set point. Locking Unit ...

  • Myson 1370064 - page 11

    11 SLIM-LINE RC 12.0 T roubleshooting (continued...) Common Installation Faults For optimum performance, this unit must be correctly sized to match the heat loss requir ements of the space it is requir ed to heat, and the heating system must be correctly designed to provide adequate flow of hot water to the unit (r efer to section 2). If the recomm ...

  • Myson 1370064 - page 12

    heating through innovation. After Sales Service: MYSON Service, Somerden Road, Hull, East Y orkshire HU9 5PE T : 01482 713927, F: 01482 789056, service.convectors@myson.co.uk Spare parts and technical help on all Convector products ar e available from MYSON Service. MYSON Eastern Avenue, T eam V alley , Gateshead, T yne & Wear NE11 0PG, UK T: 0 ...

Fabricante Myson Categoría Patio Heater

Los documentos del dispositivo Myson 1370064 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Myson
- manuales de instrucciones 1370064
- hojas de producto Myson
- folletos informativos
- o etiquetas energéticas Myson 1370064
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Myson 1370064.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Myson 1370064, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Myson 1370064. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Myson 1370064.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Myson 1370064, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Myson 1370064. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Myson 1370064.

El manual de instrucciones completo de Myson debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Myson 1370064 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Myson 1370064, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Myson 1370064 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Myson 1370064 - que deben facilitarnos los primeros pasos durante el uso de Myson 1370064
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Myson 1370064
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Myson 1370064 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Myson 1370064?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Myson 1370064, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Myson 1370064 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)