    1.0 General Information 03 2.0 Heating System Design 03 3.0 Unit Selection/Sizing 03 4.0 Location 03 5.0 Preparation 04 6.0 Fixing 04 7.0 W ater Connections 05 8.0 Electrical Connection 06 9.0 Commissioning Procedur e 07 10.0 T echnical Data 08 11.0 Operating Instructions 09 12.0 T roubleshooting 10 13.0 Maintenance 11 Contents 22369 Slimline RC Ma ...

  • Myson 1370064 - page 3

    03 SLIM-LINE RC 1.0 General Information 2.0 Heating System Design G This MYSON SLIM-LINE RC fan convector is designed for wall mounted installation with a minimum installation height of 150mm to the underside of the unit. G The SLIM-LINE RC should only be used on closed circulation, two pipe, pump assisted central heating systems. G The SLIM-LINE R ...

  • Myson 1370064 - page 4

    04 SLIM-LINE RC 5.0 Preparation Before pr oceeding with the installation, unpack the carton contents and check against the checklist below: 1. SLIM-LINE RC unit. 2. 15mm isolating valves (1 pair). 3. Instruction manual. 4. W arranty card. 5. Fixing kit (rubber mounts and cable gland). 6. Remote control handset. 6.0 Fixing G Using the fixing dimensi ...

  • Myson 1370064 - page 5

    05 SLIM-LINE RC 7.0 W ater Connections G Connect unit to system flow and return pipes using the two 15mm isolating valves (see fig. 2). Note: T o ensure ef fective venting of the heat exchanger the flow pipe should be connected to the bottom connection of the heat exchanger . Note: For SLIM-LINE RC installations pipe-work must not be routed dir ect ...

  • Myson 1370064 - page 6

    06 SLIM-LINE RC G This unit is supplied with factory fitted test leads. Remove these and discard. G A fused electrical spur with a maximum 3A fuse and a switch having 3mm separation on all poles must be provided in an easily accessible position adjacent to the unit. G Electrical cable entry to the unit should be made through the underside of the un ...

  • Myson 1370064 - page 7

    07 SLIM-LINE RC 9.0 Commissioning Procedur e G Fill and vent the system. G Open both valves fully and vent air from the heat exchanger by unscrewing the air bleed valve situated above the valves in the angled top of the chassis. G Check for leaks at pipe connections. G Refit the outer case and secure using the 2 fixing scr ews. G Switch on electric ...

  • Myson 1370064 - page 8

    T ested in accordance with BS 4856 Part 1. Flow rate 340 ltr/h (75 gal/h). Flow Rate Correction Factors: 455 ltr/h (100 gal/h) multiply by 1.03 227 ltr/h (50 gal/h) multiply by 0.96 113 ltr/h (25 gal/h) multiply by 0.85 Electrical supply 230V 50Hz T est pressur e 20bar (1MPa) Max working pressur e 10bar (1MPa) W ater connections 15mm compression Un ...

  • Myson 1370064 - page 9

    09 SLIM-LINE RC 11.0 Operating Instructions Description This SLIM-LINE RC unit is fitted with a control system that provides either automatic or manual contr ol of the unit. In automatic mode the desired temperatur e set point is selected and the unit will adjust the fan speed according to the dif ference between the actual room temperatur e and th ...

  • Myson 1370064 - page 10

    Manual Manual mode can be used for air circulation without heat or for manual control of the heating function. Use ‘+’ to scroll Selected fan speed beyond 35°C displayed Or use ‘-’ to scroll below 15°C Scrolling back out of manual using the ‘+’ or ‘–’ button will r evert the unit back to last temperature set point. Locking Unit ...

  • Myson 1370064 - page 11

    11 SLIM-LINE RC 12.0 T roubleshooting (continued...) Common Installation Faults For optimum performance, this unit must be correctly sized to match the heat loss requir ements of the space it is requir ed to heat, and the heating system must be correctly designed to provide adequate flow of hot water to the unit (r efer to section 2). If the recomm ...

  • Myson 1370064 - page 12

    heating through innovation. After Sales Service: MYSON Service, Somerden Road, Hull, East Y orkshire HU9 5PE T : 01482 713927, F: 01482 789056, service.convectors@myson.co.uk Spare parts and technical help on all Convector products ar e available from MYSON Service. MYSON Eastern Avenue, T eam V alley , Gateshead, T yne & Wear NE11 0PG, UK T: 0 ...

Fabricant Myson Catégorie Patio Heater

Les documents que nous recevons du fabricant de l'appareilMyson 1370064 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Myson
- manuels d’utilisations 1370064
- fiches produit Myson
- dépliants
- ou étiquettes-énergie Myson 1370064
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Myson 1370064.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Myson 1370064, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Myson 1370064. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Myson 1370064.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Myson 1370064, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Myson 1370064 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Myson 1370064.

Le manuel d’utilisation complet Myson, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Myson 1370064 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Myson 1370064, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMyson 1370064 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Myson 1370064 - qui devraient nous aider dans les premières étapes lors de l'utilisation Myson 1370064
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Myson 1370064
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Myson 1370064 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Myson 1370064?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Myson 1370064, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Myson 1370064 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)