    CATALOG NO. 6100.61E Effective: 02-01-05 Replaces: 03-01-03 Part No. 240790 INST ALLA TION AND OPERA TING INSTRUCTIONS Models 105B Brass VERSA ABOVE GROUND POOL and SP A HEA TER WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death. — WHAT TO DO ...

  • Raypak Versa 105B - page 2

    ...

  • Raypak Versa 105B - page 3

    Contents 4 PART ONE - Owner's Operating Instructions 4 SECTION 1 / START-UP PROCEDURES 4 Before Start-Up 5 Lighting Instructions & Shut-Off Procedures (manually lighted pilot MV) 6 Operating Instructions & Shut-Off Procedures (automatically lighted pilot IID) 7 After Start-Up 7 SECTION 2 / CAUTION 7 SECTION 3 / MAINTENANCE & CARE P ...

  • Raypak Versa 105B - page 4

    P ART ONE - OWNER'S OPERA TING INSTRUCTIONS BEFORE START-UP BURNERS Clean main burners and air louvers of dust, lint and debris. Keep heater area clear and free from com- bustibles, flammable liquids and chemicals. Do not obstruct the flow of combustion and ventilating air. 4 WATER First thing, insure that system is filled with water and have ...

  • Raypak Versa 105B - page 5

    1. STOP! Read the safety information above. 2. Set the thermostat on the lowest setting. 3. Turn On/Off switch to the "Off" position. 4. Remove heater door panel. 5. Push in gas control knob slightly and turn clock- wise to "Off". NOTE: Knob cannot be turned from "Pilot" to "Off" unless knob is pushed in slig ...

  • Raypak Versa 105B - page 6

    TO TURN OFF GAS TO APPLIANCE 1. STOP! Read the safety information above. 2. Set the thermostat to the lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. 5. Remove heater door panel. 6. Turn gas control kno ...

  • Raypak Versa 105B - page 7

    AFTER START-UP Feel the inlet and outlet pipes. Outlet pipe should be only slightly warmer than the inlet. It should not be hot. WARNING: Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance. VISUAL INSPECTION With the heater on, remove the door and make a visual check of the pilot and ...

  • Raypak Versa 105B - page 8

    COLD WEATHER OPERATION MODERATE CLIMATE: Heater operation can continue during short term cold spells. When temperatures are below freezing, flow (continuous pump operation) must be maintained. CAUTION: Do not use the heater to maintain water temperatures just above freezing or for freeze protec- tion. When heaters are used during freezing weather c ...

  • Raypak Versa 105B - page 9

    P ART 2 - INST ALLA TION / SERVICE INSTRUCTIONS SECTION 1 RECEIVING EQUIPMENT On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, a note should be made on the Bill of Lading when signing for equipment. Remove the heater from the carton and if it is damaged, report the dam ...

  • Raypak Versa 105B - page 10

    CLEARANCES ALL HEATERS For clearances from combustible surfaces, see chart below. Clearances from Combustible construction. Indoor Installation: Top* (Drafthood) - 30"; Vent - 6"; Back - 5"; Right Side - 6"; Left Side - 6"; Floor - 0. Outdoor Installation: Top* (Stackless Top) - unobstructed; Back - 5"; Sides - 6" ...

  • Raypak Versa 105B - page 11

    HIGH WIND CONDITIONS (OUTDOOR UNITS ONLY) In areas where high winds are frequent, it may be necessary to locate the heater a minimum of 3' from high vertical walls, or install a wind break so the heater is not in direct wind current. In areas of daily high winds, it may be necessary to replace the outdoor stackless top with a stack adapter in ...

  • Raypak Versa 105B - page 12

    VENTING CONNECTIONS VENT TERMINAL (Outdoor) STACKLESS TOP STEP 1: Remove the (4) screws which fasten jacket top to heater. STEP 2: Lower outdoor top onto unit lining up slots in outdoor top with screw holes in jacket top. STEP 3: Reinstall (4) screws to secure jacket top and outdoor top to unit. VENT TERMINAL (Outdoor) OUTDOOR STACK STEP 1 Line up ...

  • Raypak Versa 105B - page 13

    VENT PIPING WARNING: Indoor boilers require a draft hood that must be connected to a vent pipe and properly vented to the outside. Failure to follow this procedure can cause fire or fatal carbon monoxide poisoning. Vent piping the same size or larger than the draft hood outlet is recommended, however, when the total vent height is at least ten (10) ...

  • Raypak Versa 105B - page 14

    GAS SUPPLY CONNECTIONS Gas piping must have a sediment trap ahead of the heater gas controls, and a manual shut-off valve located outside the heater jacket. All gas piping should be tested after installation in accordance with local codes. CAUTION: The heater and its manual shut off valve must be disconnected from the gas supply during any pressure ...

  • Raypak Versa 105B - page 15

    PLUMBING FOR WATER CONNECTIONS LOCATION The VERSA heater requires water flow and positive pressure to fire and operate properly. It must therefore be installed downstream of the discharge side of the filter pump. A typical installation is plumbed as follows: 1. The inlet side of the filter is plumbed directly to the discharge side of the filter pum ...

  • Raypak Versa 105B - page 16

    EXTERNAL AUXILIARY BYPASS VALVE (Where required) An auxiliary bypass valve should be used when flow rates exceed 115 GPM (usually a high performance pump size larger than 2 HP will exceed this flow rate). This valve is required to complement the function of the automatic bypass valve, particularly when starting the heater in winter or early spring ...

  • Raypak Versa 105B - page 17

    ELECTRICAL WIRING NOTE: If it is necessary to replace any of the original wiring, it must be replaced with 105 °C wire or its equivalent, except all black wire must be replaced with 150 °C wire or its equivalent. MILLIVOLT SYSTEM The Millivolt System Residential Heater is equipped with a self-generating electrical system in which the electric cur ...

  • Raypak Versa 105B - page 18

    18 WIRING DIAGRAM MILLIVOLT UNITS Fig. #2353 WIRING DIAGRAM KEY Fig. # 8096 PINK CONNECTOR BLUE CONNECTOR * * If required by local code, install at this location. ...

  • Raypak Versa 105B - page 19

    WIRING DIAGRAM I.I.D. UNITS IGNITION DEVICE - HONEYWELL Fig. # 9250 19 ...

  • Raypak Versa 105B - page 20

    WIRING DIAGRAM IID UNITS IGNITION DEVICE - ROBERTSHAW Fig. # 9251 20 ...

  • Raypak Versa 105B - page 21

    SECTION 4 / SERVICING INSTRUCTIONS GENERAL LOCATION OF CONTROLS 21 CONTROLS/ADJUSTMENTS/ REPLACEMENTS TEMPERATURE CONTROLS The water temperature is controlled by the heater thermostat on the upper front panel of the heater. The control center contains an On/Off toggle switch and a thermostat. The switch functions as a means for turning the heater o ...

  • Raypak Versa 105B - page 22

    PRESSURE SWITCH ADJUSTMENT: 1. With pump and heater on, turn adjustment knob ( clockwise) until a click is heard from the gas valve. 2. Turn adjustment knob (counter clockwise) 1/4 turn. 3. Turn pump off and on several times. Heater should shut off immediately. If it does not, repeat steps above until proper adjustment is made. Adjustment Knob Fig. ...

  • Raypak Versa 105B - page 23

    BURNER DRAWER REMOVAL 1. Shut off main electrical power switch to heater. 2. Shut off gas upstream of heater. 3. Remove front door. 4. Disconnect gas line from gas valve. 5. Remove (2) screws that mount burner tray to unit. 6. Disconnect wires that terminate at gas valve. 7. Slide out burner tray. 8. Reverse above procedure to reinstall. GAS VALVE ...

  • Raypak Versa 105B - page 24

    TUBE CLEANING PROCEDURE Establish a regular inspection schedule, frequency depending on local water condition and severity of service. Do not let the tubes clog up solidly. Clean out deposits over 1/16" in thickness. The heater may be cleaned from the return header side, without breaking pipe connections. It is prefer- able, however, to remove ...

  • Raypak Versa 105B - page 25

    25 CONTROL IMMERSION WELL REPLACEMENT 1. Shut water off to heater and drain heat exchanger. 2. Remove jacket top panel. 3. Remove old control well with bushing and sleeve, with 7/8" wrench or socket. 4. Slip "o" ring gasket over control well and install in header. "O" Ring Gasket Well Assembly Fig. #8101.0 UNITHERM GOVERNOR ...

  • Raypak Versa 105B - page 26

    SECTION 5 / TROUBLE SHOOTING GUIDE IMPORTANT NOTICE These instructions are primarily intended for the use of qualified personnel specifically trained and experienced in the installation of this type of heating equipment and related system components. Installation and service personnel may be required by some states to be licensed. Persons not quali ...

  • Raypak Versa 105B - page 27

    If pilot burner remains lit. Jump across pressure switch terminals If main burner does not fire, remove jumper Check for adequate water flow from filter Replace pressure switch Jump across thermostat If main burner fires, remove jumper If main burner does NOT fire... Jump across each high limit and remove jumper Replace thermostat Replace high limi ...

  • Raypak Versa 105B - page 28

    ELECTRICAL (ELECTRONIC IGNITION IID) WARNING HIGH VOLTAGE For qualified Technicians ONLY NOTE: Some heaters may be equipped with an ignition module that shuts off pilot gas if pilot fails to light. To reset, interrupt power to heater. Intermittent Pilot System TROUBLESHOOTING HONEYWELL S8600 NOTE: Before troubleshooting, familiarize yourself with t ...

  • Raypak Versa 105B - page 29

    SECTION 6/REPLACEMENT PARTS LIST NOTE: To supply the correct part it is important that you state the model number, serial number and type of gas when applicable. Any part returned for replacement under standard company warranties must be properly tagged with RAYPAK return parts tag, completely filled in with the heater serial number, model number, ...

  • Raypak Versa 105B - page 30

    30 ...

  • Raypak Versa 105B - page 31

    31 ...

  • Raypak Versa 105B - page 32

    32 ...

Fabricante Raypak Categoría Swimming Pool Heater

Los documentos del dispositivo Raypak Versa 105B que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Raypak
- manuales de instrucciones Versa 105B
- hojas de producto Raypak
- folletos informativos
- o etiquetas energéticas Raypak Versa 105B
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Raypak Versa 105B.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Raypak Versa 105B, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Raypak Versa 105B. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Raypak Versa 105B.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Raypak Versa 105B, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Raypak Versa 105B. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Raypak Versa 105B.

El manual de instrucciones completo de Raypak debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Raypak Versa 105B - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Raypak Versa 105B, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Raypak Versa 105B que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Raypak Versa 105B - que deben facilitarnos los primeros pasos durante el uso de Raypak Versa 105B
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Raypak Versa 105B
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Raypak Versa 105B en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Raypak Versa 105B?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Raypak Versa 105B, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Raypak Versa 105B probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)