    323356B-01 May 2003 © 2002–2003 Nationa l Instruments Corp. A ll rights res erved. FieldPoint™, Nati onal Instruments™, NI™, and ni.com™ are trademarks of N ational Instruments Corpo ration. Product and company names ment ioned herein are trademark s or trade names of their respective c ompanies. For patents covering National Inst rument ...

  • National Instruments FP-PG-522 - page 2

    FP-PG-522 and cFP-PG-522 2 ni.com Installing the FP-PG-522 The FP-PG-522 mounts on a FieldPoint terminal base (FP-TB- x ), which provides operating po wer to the module. Instal ling the FP-PG-522 onto a po wered termin al base does not disrupt the operation of the bank. T o install the FP-PG-522, refer to Figure 1 and co mplete the follow ing steps ...

  • National Instruments FP-PG-522 - page 3

    © National Instruments Corp . 3 FP-PG-522 and cFP-PG-522 T o install the cFP-PG-522, refe r to Figure 2 and complete the follow ing steps: 1. Align the capti ve scre ws on th e cFP-PG-522 with the holes on the backplane. The alignment keys on the cFP-PG-522 pre vent backward insertion. 2. Press firm ly to seat the cFP-PG-522 on th e backplane. 3. ...

  • National Instruments FP-PG-522 - page 4

    FP-PG-522 and cFP-PG-522 4 ni.com Wiring the [c]FP-PG-522 The FP-TB- x terminal base ha s connections for each of the eight output channels and for an exte rnal power supply to po wer the output channels and field de vices. The cFP-CB- x connector block provides th e same connections. Each ch annel has one outpu t terminal (V OUT ), two supply term ...

  • National Instruments FP-PG-522 - page 5

    © National Instruments Corp . 5 FP-PG-522 and cFP-PG-522 T able 1 lists the term inal assign ments for the signals of each channel. T erminal assignments are also listed on the side pane l of the cFP-PG-522 and un der the slide-in card on the front of the FP-PG-522. Pulse Output Circuit The [c]FP-PG-522 output channels are opti cally isolated fr o ...

  • National Instruments FP-PG-522 - page 6

    FP-PG-522 and cFP-PG-522 6 ni.com T able 2 sho ws some common combinations of output current le v els on sev eral channels. In the ON state, the ef fe cti ve resist ance between V OUT and COM is 0.12 Ω , which causes a v oltage drop. F or example, if the output current is 1 A, the voltage drop is 0.12 V : (1 A × 0.12 Ω ) = 0.12 V Configuring t ...

  • National Instruments FP-PG-522 - page 7

    © National Instruments Corp . 7 FP-PG-522 and cFP-PG-522 A channel set to Continuo us mode must be swit ched to Finite mode in order to stop pulse generation. When switched to Fi nite mode from Continuous mode, a channel finishes generating the current pulse and then stops. On Time The On T ime attrib ute for a channel controls the duration of the ...

  • National Instruments FP-PG-522 - page 8

    FP-PG-522 and cFP-PG-522 8 ni.com T o calcula te On Time and Off T ime , di vide the desired On or Of f T ime for the pulse b y the Resoluti on. F or examp le, to generate a pulse that is on for 3.5 s and off for 0.25 s using a 100 µ s Resolution, set the On T ime to 35,000 and the Off Time to 2,500 (100 µ s = 0.0001 s; On T ime = 3.5/0.0001 = 35 ...

  • National Instruments FP-PG-522 - page 9

    © National Instruments Corp . 9 FP-PG-522 and cFP-PG-522 va lues, which reflect the number of pulses each channel has left to generate after the current puls e. When you send the Generate Pulses command to one of these channels, the data immediately changes to reflect the number of pulses that remain. The data value starts at the total number of p ...

  • National Instruments FP-PG-522 - page 10

    FP-PG-522 and cFP-PG-522 10 ni.com When the network module recogni zes the [c]FP-PG-52 2, it sends initial conf iguration informat ion to the [c]FP-PG-522. After the [c]FP-PG-522 recei ves this in itial information , the green READY indicator lights and the [c]FP-PG-5 22 is in normal operating mode. In addition to the green POWER and READY indicato ...

  • National Instruments FP-PG-522 - page 11

    © National Instruments Corp. 1 1 FP-PG-522 and cFP-PG-522 follow ing symbol stamped beside it: . Connect the backplane PE ground terminal to the system safety ground using 14 A WG (1.6 mm) wire with a ring lug. Use the 5/16 in. panhead screw shipped with the backplane to secure the ring lug to the backplane PE ground terminal. • As with any haza ...

  • National Instruments FP-PG-522 - page 12

    FP-PG-522 and cFP-PG-522 12 ni.com Physical Char acteristics Indicators ............ ........... ......... .......... Green POWER and READY indicators, eight green output st ate indicators W eight FP-PG-522 .... ........... ........... ........ 130 g (4.6 oz) cFP-PG-522 .. ............. ............ ..... 100 g (3.5 oz) Power Requirements Power fro ...

  • National Instruments FP-PG-522 - page 13

    © National Instruments Corp. 1 3 FP-PG-522 and cFP-PG-522 Operating shock (IEC 60068-2-27)........... ........... ........ 50 g, 3 ms half sine, 18 shocks at 6 orientations; 30 g, 11 ms half sine, 18 shocks at 6 orientations Safety This product is designed to meet the requirements of the following standards of safety for electric al equipment for ...

  • National Instruments FP-PG-522 - page 14

    FP-PG-522 and cFP-PG-522 14 ni.com Mechanical Dimensions Figure 5 sho ws the mechanical dimen sions of the FP-PG-522 installed on a termin al base. If you are using the cFP-PG-522, refer to your Compact FieldPo int controller user manual for the dimensions and cabling clearance require ments of the Compact FieldPoint system. Figure 5. FP-PG-522 Mec ...

  • National Instruments FP-PG-522 - page 15

    © National Instruments Corp. 1 5 FP-PG-522 and cFP-PG-522 Czech Republic 420 2 2423 5774, Denmark 45 45 76 26 00, Finland 385 0 9 725 725 11, France 33 0 1 48 14 24 24, Germany 49 0 89 741 31 30, Greece 30 2 10 42 96 427, India 91 80 51190000, Israel 972 0 3 6393737, Italy 39 02 413091, Japan 81 3 54 72 2970, K orea 82 02 3451 3400, Malaysia 603 9 ...

Fabricante National Instruments Categoría Blood Pressure Monitor

Los documentos del dispositivo National Instruments FP-PG-522 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos National Instruments
- manuales de instrucciones FP-PG-522
- hojas de producto National Instruments
- folletos informativos
- o etiquetas energéticas National Instruments FP-PG-522
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones National Instruments FP-PG-522.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje National Instruments FP-PG-522, instrucciones de servicio, instrucciones cortas o instrucciones de usuario National Instruments FP-PG-522. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto National Instruments FP-PG-522.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo National Instruments FP-PG-522, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar National Instruments FP-PG-522. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de National Instruments FP-PG-522.

El manual de instrucciones completo de National Instruments debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual National Instruments FP-PG-522 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice National Instruments FP-PG-522, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de National Instruments FP-PG-522 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo National Instruments FP-PG-522 - que deben facilitarnos los primeros pasos durante el uso de National Instruments FP-PG-522
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con National Instruments FP-PG-522
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de National Instruments FP-PG-522 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de National Instruments FP-PG-522?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con National Instruments FP-PG-522, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con National Instruments FP-PG-522 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)