Manuel d’utilisation National Instruments FP-PG-522

15 pages 0.37 mb
Télécharger

Aller à la page of 15

Summary
  • National Instruments FP-PG-522 - page 1

    323356B-01 May 2003 © 2002–2003 Nationa l Instruments Corp. A ll rights res erved. FieldPoint™, Nati onal Instruments™, NI™, and ni.com™ are trademarks of N ational Instruments Corpo ration. Product and company names ment ioned herein are trademark s or trade names of their respective c ompanies. For patents covering National Inst rument ...

  • National Instruments FP-PG-522 - page 2

    FP-PG-522 and cFP-PG-522 2 ni.com Installing the FP-PG-522 The FP-PG-522 mounts on a FieldPoint terminal base (FP-TB- x ), which provides operating po wer to the module. Instal ling the FP-PG-522 onto a po wered termin al base does not disrupt the operation of the bank. T o install the FP-PG-522, refer to Figure 1 and co mplete the follow ing steps ...

  • National Instruments FP-PG-522 - page 3

    © National Instruments Corp . 3 FP-PG-522 and cFP-PG-522 T o install the cFP-PG-522, refe r to Figure 2 and complete the follow ing steps: 1. Align the capti ve scre ws on th e cFP-PG-522 with the holes on the backplane. The alignment keys on the cFP-PG-522 pre vent backward insertion. 2. Press firm ly to seat the cFP-PG-522 on th e backplane. 3. ...

  • National Instruments FP-PG-522 - page 4

    FP-PG-522 and cFP-PG-522 4 ni.com Wiring the [c]FP-PG-522 The FP-TB- x terminal base ha s connections for each of the eight output channels and for an exte rnal power supply to po wer the output channels and field de vices. The cFP-CB- x connector block provides th e same connections. Each ch annel has one outpu t terminal (V OUT ), two supply term ...

  • National Instruments FP-PG-522 - page 5

    © National Instruments Corp . 5 FP-PG-522 and cFP-PG-522 T able 1 lists the term inal assign ments for the signals of each channel. T erminal assignments are also listed on the side pane l of the cFP-PG-522 and un der the slide-in card on the front of the FP-PG-522. Pulse Output Circuit The [c]FP-PG-522 output channels are opti cally isolated fr o ...

  • National Instruments FP-PG-522 - page 6

    FP-PG-522 and cFP-PG-522 6 ni.com T able 2 sho ws some common combinations of output current le v els on sev eral channels. In the ON state, the ef fe cti ve resist ance between V OUT and COM is 0.12 Ω , which causes a v oltage drop. F or example, if the output current is 1 A, the voltage drop is 0.12 V : (1 A × 0.12 Ω ) = 0.12 V Configuring t ...

  • National Instruments FP-PG-522 - page 7

    © National Instruments Corp . 7 FP-PG-522 and cFP-PG-522 A channel set to Continuo us mode must be swit ched to Finite mode in order to stop pulse generation. When switched to Fi nite mode from Continuous mode, a channel finishes generating the current pulse and then stops. On Time The On T ime attrib ute for a channel controls the duration of the ...

  • National Instruments FP-PG-522 - page 8

    FP-PG-522 and cFP-PG-522 8 ni.com T o calcula te On Time and Off T ime , di vide the desired On or Of f T ime for the pulse b y the Resoluti on. F or examp le, to generate a pulse that is on for 3.5 s and off for 0.25 s using a 100 µ s Resolution, set the On T ime to 35,000 and the Off Time to 2,500 (100 µ s = 0.0001 s; On T ime = 3.5/0.0001 = 35 ...

  • National Instruments FP-PG-522 - page 9

    © National Instruments Corp . 9 FP-PG-522 and cFP-PG-522 va lues, which reflect the number of pulses each channel has left to generate after the current puls e. When you send the Generate Pulses command to one of these channels, the data immediately changes to reflect the number of pulses that remain. The data value starts at the total number of p ...

  • National Instruments FP-PG-522 - page 10

    FP-PG-522 and cFP-PG-522 10 ni.com When the network module recogni zes the [c]FP-PG-52 2, it sends initial conf iguration informat ion to the [c]FP-PG-522. After the [c]FP-PG-522 recei ves this in itial information , the green READY indicator lights and the [c]FP-PG-5 22 is in normal operating mode. In addition to the green POWER and READY indicato ...

  • National Instruments FP-PG-522 - page 11

    © National Instruments Corp. 1 1 FP-PG-522 and cFP-PG-522 follow ing symbol stamped beside it: . Connect the backplane PE ground terminal to the system safety ground using 14 A WG (1.6 mm) wire with a ring lug. Use the 5/16 in. panhead screw shipped with the backplane to secure the ring lug to the backplane PE ground terminal. • As with any haza ...

  • National Instruments FP-PG-522 - page 12

    FP-PG-522 and cFP-PG-522 12 ni.com Physical Char acteristics Indicators ............ ........... ......... .......... Green POWER and READY indicators, eight green output st ate indicators W eight FP-PG-522 .... ........... ........... ........ 130 g (4.6 oz) cFP-PG-522 .. ............. ............ ..... 100 g (3.5 oz) Power Requirements Power fro ...

  • National Instruments FP-PG-522 - page 13

    © National Instruments Corp. 1 3 FP-PG-522 and cFP-PG-522 Operating shock (IEC 60068-2-27)........... ........... ........ 50 g, 3 ms half sine, 18 shocks at 6 orientations; 30 g, 11 ms half sine, 18 shocks at 6 orientations Safety This product is designed to meet the requirements of the following standards of safety for electric al equipment for ...

  • National Instruments FP-PG-522 - page 14

    FP-PG-522 and cFP-PG-522 14 ni.com Mechanical Dimensions Figure 5 sho ws the mechanical dimen sions of the FP-PG-522 installed on a termin al base. If you are using the cFP-PG-522, refer to your Compact FieldPo int controller user manual for the dimensions and cabling clearance require ments of the Compact FieldPoint system. Figure 5. FP-PG-522 Mec ...

  • National Instruments FP-PG-522 - page 15

    © National Instruments Corp. 1 5 FP-PG-522 and cFP-PG-522 Czech Republic 420 2 2423 5774, Denmark 45 45 76 26 00, Finland 385 0 9 725 725 11, France 33 0 1 48 14 24 24, Germany 49 0 89 741 31 30, Greece 30 2 10 42 96 427, India 91 80 51190000, Israel 972 0 3 6393737, Italy 39 02 413091, Japan 81 3 54 72 2970, K orea 82 02 3451 3400, Malaysia 603 9 ...

Fabricant National Instruments Catégorie Blood Pressure Monitor

Les documents que nous recevons du fabricant de l'appareilNational Instruments FP-PG-522 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques National Instruments
- manuels d’utilisations FP-PG-522
- fiches produit National Instruments
- dépliants
- ou étiquettes-énergie National Instruments FP-PG-522
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation National Instruments FP-PG-522.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation National Instruments FP-PG-522, manuels d’entretien, brefs manuels ou manuels de l’utilisateur National Instruments FP-PG-522. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit National Instruments FP-PG-522.

Manuel d’utilisation complet de l’appareil National Instruments FP-PG-522, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser National Instruments FP-PG-522 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs National Instruments FP-PG-522.

Le manuel d’utilisation complet National Instruments, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel National Instruments FP-PG-522 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières National Instruments FP-PG-522, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNational Instruments FP-PG-522 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil National Instruments FP-PG-522 - qui devraient nous aider dans les premières étapes lors de l'utilisation National Instruments FP-PG-522
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de National Instruments FP-PG-522
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service National Instruments FP-PG-522 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de National Instruments FP-PG-522?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec National Instruments FP-PG-522, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec National Instruments FP-PG-522 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)