Manual de instrucciones IC Intracom 460835

74 de páginas No relevante
Descargar

Pasar a la página of 74

Summary
  • IC Intracom 460835 - page 1

    BAR CODE BAR CODE ...

  • IC Intracom 460835 - page 2

    Progra mming Menu V3.8 a Notice The ma nufa cturer shall not be li a ble f or te chnical or editorial errors or omissions contained herein; nor f or incidental or con sequenti al da mage s in conne ction with the furnishing,perf orma nce or use of use the publication. ...

  • IC Intracom 460835 - page 3

    1 Contents Cha pter 1 Description 1.1 Notice ....................................................... 3 1.2 Introduction ........................................... 4 1.3 Codes Read ........................................... 4 1.4 Installation .............................................. 4 1.5 Pin Assign ment ..................................... ...

  • IC Intracom 460835 - page 4

    2 5.12 Code 2 of 6 Para meters ......................... 44 5.13 LCD 25 Para meters ............................. 46 5.14 T ele pen Para meters ............................. 48 5.15 GS1 DataBar (RSS Code) ........................ 50 Cha pter 6 M iscella neous Para meters 6.1 La nguage Sele ction .............................. 52 6.2 Bar Code ID ... ...

  • IC Intracom 460835 - page 5

    3 Cha pter 1 De scri ption 1.1 General Tha nk you f or purcha sing this barcode sca nner with a n a dva nced a nd versatile de coder .The de coder works with variety of barcode types,reading devices, a nd computer interfa ce s.It discri min ate s over twenty different symbologies automatically. This menu provide s a n e a sy way to conf igure the d ...

  • IC Intracom 460835 - page 6

    4 1.2 Introduction The De coder is a n a dva nced a nd versatile de coding fa cility f or barcoding syste ms .It work s with variety of bar code types, reading devices, a nd computer interfa ce s. It discri min ate s a bout twenty different symbologies automatically. This menu provide a n e a sy way to conf ig the de coding option s a nd interfa ce ...

  • IC Intracom 460835 - page 7

    5 Power supply for RS-232C scanner– There are 3 ways to supplying the power, use ex- ternal +5V power supply, use optional power cable (KBDC) which ta king the power from KB wedge or if the host supports +5V power from pin 9. Installing the scanner to the Host System – 1. Turn off the host system. 2. Connect the power if needed. 3. Connect to t ...

  • IC Intracom 460835 - page 8

    6 1.5 Pin Assignment A> Input Port for Mini Decoder DB 9 Male Pin No. W a nd / CCD / Slot Reader La ser Sca nner 1 N.C. S.O.S. 2 DA T A DA T A 3 N.C. N.C. 4 N.C. N.C. 5 N.C. TRIGGER 6 N.C. P. E. 7 GND GND 8 SHIELD SHIELD 9 +5V +5V B> Output Port 1. PC Keyboard Output DIN 5 MALE DIN 5 FEMALE Pin No. Function Pin No. Function 1 HOST CLK 1 KB CL ...

  • IC Intracom 460835 - page 9

    7 6 1 5 9 1 2 4 3 1 3 2 4 6 7 8 5 2 1 3 4 2 5 1 3 8 7 6 4 6 1 5 9 2. RS-232 Output DB 9 Female Pin No. Function 2 TXD 3 RXD 5 GND 7 CTS 8 RTS Power Lead Vcc (+5V) 3. W AND Emulation Output DB 9 Female Pin No. Function 2 DA T A 7 GND 9 Vcc (+5V) 4. ADB Interface MiniDIN 4 MALE MiniDIN 4 FEMALE Pin No. Function Pin No. Function 1 ADB 1 ADB 3 Vcc 3 Vc ...

  • IC Intracom 460835 - page 10

    8 Cha pter 2 Conf iguration - General 2.1 Flow Chart ...

  • IC Intracom 460835 - page 11

    9 2.2 Loop of Progra mming The philosophy of progra mming para meters ha s been shown on the flow chart of 2.1. Ba sically user should 1.Sca n Start of Conf iguration. 2.Sca n all ne ce ssary la bels f or para meters that meet a pplication s. 3.Sca n End of Conf iguration to end the progra mming. 4.T o perma nently save the settings you progra mmed ...

  • IC Intracom 460835 - page 12

    10 % $ + / 0 % $ + / 1 % $ + / 2 % $ + / 3 % $ + / 4 % $ + / 6 % $ + / 5 2.4 Main Page of Configuration Save Para meters Recall Stored Para meters Set All Defaults Start Configuration End Configuration Abort Configuration V ersion Inf ormation Save Para meters - The para meter settings will be saved perma nently . Re call Stored Para meters - Re pl ...

  • IC Intracom 460835 - page 13

    1 1 Cha pter 3 Interf a ce a nd Re a ding Mode Sele ction 3.1 Interface Selection <Keyboard Mode> RS232 Mode WAND Emulation USB Mode 3.2 Memory Function<HC102M Only> <Enable> Disa ble % 0 0 U0 % 0 0 U8 % 0 0 M 2 % 0 XI 2 % 0 XI 0 % 0 XO 8 ...

  • IC Intracom 460835 - page 14

    12 3.3 Reading Mode Selection <Good Read OFF> Trigger ON/OFF Continuous/Trigger OFF T e sting Continuous/Auto Power On Fla sh Fla sh/Auto Power On Reserved1 Re served 2 ( Auto Sen se Option) Reserved3 Reserved4 Reserved5 % 0 2 7 1 % 0 2 7 0 % 0 2 7 2 % 0 2 7 5 % 0 2 7 3 % 0 2 7 4 % 0 2 7 6 % 0 2 7 7 % 0 9 F 8 % 0 9 F 9 % 0 9 F A % 0 9 F B ...

  • IC Intracom 460835 - page 15

    13 Ch.4 Communication Para meters 4.1 RS232 Communication Para m eters A> Set Up BAUD Rate 1200 2400 4800 <9600> 19200 38400 B> Set Up Data Bits 7 Data Bits <8 Data Bits> C> Set Up Stop Bits <1 Bit> 2 Bits % 0 Y8 0 % 0 Y8 8 % 0 Y7 1 % 0 Y7 2 % 0 Y7 3 % 0 Y7 7 % 0 Y7 4 % 0 YO 8 % 0 YO 0 % 0 Y7 5 ...

  • IC Intracom 460835 - page 16

    14 D> Set Up Parity <None> Even Odd Mark Spa ce E> Ha ndsha king RTS/CTS Enable <RTS/CTS Disa ble> ACK/NAK Enable <ACK/NAK Disa ble> XON/XOFF Enable <XON/XOFF Disa ble> % 0 YN7 % 0 YN2 % 0 YN3 % 0 YN1 % 0 YN0 % 0 1 8 8 % 0 1 8 0 % 0 1 4 4 % 0 1 4 0 % 0 3 K 4 % 0 3 K 0 ...

  • IC Intracom 460835 - page 17

    15 4.2 Keyboard W edge Mode Para meters A> T ermin al T ype <IBM PC/A T , PS/2> IBM PC/XT IBM PS/2 25, 30 NEC 9800 Apple De s ktop Bus( ADB ) IBM 5550 IBM 122 Key (1) IBM 102 Key IBM 122 Key (2) Reserved 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 % 0 Z F 0 % 0 Z F 1 % 0 Z F 2 % 0 Z F 3 % 0 Z F 4 % 0 Z F 5 % 0 Z F 6 % 0 Z F 7 % 0 Z F 8 % ...

  • IC Intracom 460835 - page 18

    16 B> Upper/Lower Ca se <No Cha nge> Upper Ca se Lower Ca se C> Ca pslock Dete ction Enable <Disable> D> Send Chara cter by AL T Method Enable <Disable> E>Sele ct Numerical Pa d ON <OFF> % 0 3 3 0 % 0 3 3 1 % 0 3 3 2 % 0 X8 8 % 0 X8 0 % 0 3 O 8 % 0 3 O 0 % 0 1 K4 % 0 1 K0 ...

  • IC Intracom 460835 - page 19

    17 4.3 Output Chara cters Para meters A> Sele ct T ermin ator <CR+LF> None CR LF Spa ce HT(T AB) STX-ETX % 7 S0 + % 7 S2 + % 7 S4 + % 7 S5 + % 7 S7 + % 7 S1 + % 7 S3 + ...

  • IC Intracom 460835 - page 20

    18 B> Time-out Between Characters <0 ms> 5 ms 10 ms 25 ms 50 ms 100 ms 200 ms 300 ms % 0 0 7 0 % 0 0 7 1 % 0 0 7 2 % 0 0 7 3 % 0 0 7 4 % 0 0 7 5 % 0 0 7 6 % 0 0 7 7 ...

  • IC Intracom 460835 - page 21

    19 4.4 W a nd Emulation Mode Para meters A> TTL Level Re pre sentation <Bar Equals High> Bar Equals Low B> Sca n Speed Sele ction <Fa st> Slow C> Output Format Selection <Output a s Code 39> Output a s Code 39 Full ASCII Output a s Origin al Code Format % 0 2 K 4 % 0 2 K 0 % 0 2 8 8 % 0 2 8 0 % 0 2 O 8 % 0 2 O 0 % 0 XK 4 ...

  • IC Intracom 460835 - page 22

    20 Ch.5 Bar Code s & Others 5.1 Symbologies Selection UPC-A <ON> OFF UPC-E <ON> OFF EAN-13/JAN-13/ISBN-13 <ON> OFF EAN-8/JAN-8 <ON> OFF CODE 39 <ON> OFF CODE 128 <ON> OFF CODABAR/N W7 <ON> OFF % 0 A4 4 % 0 A4 0 % 0 BO 8 % 0 BO 0 % 0 A2 2 % 0 A2 0 % 0 A1 1 % 0 A1 0 % 0 EO 8 % 0 EO 0 % 0 F O 8 % 0 F O 0 % ...

  • IC Intracom 460835 - page 23

    21 Interleave 25 <ON> OFF Industrial 25 ON <OFF> Matrix 25 ON <OFF> CODE 93 ON <OFF> CODE 1 1 ON <OFF> China Postage ON <OFF> MSI/PLESSEY ON <OFF> % 0 G O 8 % 0 G O 0 % 0 HO 8 % 0 HO 0 % 0 I O 8 % 0 I O 0 % 0 KO 8 % 0 KO 0 % 0 L O 8 % 0 L O 0 % 0 M O 8 % 0 M O 0 % 0 NO 8 % 0 NO 0 ...

  • IC Intracom 460835 - page 24

    22 Code 2 of 6 ON <OFF> LCD25 ON <OFF> T ele pen ON <OFF> Reserved5 ON <OFF> Reserved6 ON <OFF> % 0 PO 8 % 0 PO 0 % 0 Q O 8 % 0 Q O 0 % 0 RO 8 % 0 RO 0 % 0 SO 8 % 0 SO 0 % 0 T O 8 % 0 T O 0 ...

  • IC Intracom 460835 - page 25

    23 % 0 UO 8 % 0 UO 0 % 0 VO 8 % 0 VO 0 % 1 A/ + % 0 W O 8 % 0 W O 0 GS1 DataBar Omnidire ction al ON <OFF> GS1 DataBar Li mited ON <OFF> GS1 DataBar Expa nded ON <OFF> Sele ct All Bar Code s ...

  • IC Intracom 460835 - page 26

    24 5.2 UPC/EAN/JAN Para meters A> Re a ding T ype UPCA=EAN13 ON UPCA=EAN13<OFF> ISBN-10 Enable ISBN-13 <Enable> ISSN Enable ISSN <Disable> Decode with Supplement <Autodiscriminate Supplement> Expa nd UPC-E Enable Expa nd UPC-E <Disable> EAN8=EAN13 Enable EAN8=EAN13 <Disable> GTIN Format Enable GTIN Format < ...

  • IC Intracom 460835 - page 27

    25 B> Supplementals Set Up <Not T ra n smit> T ra n smit 2 Code T ra n smit 5 Code T ra n smit 2&5 Code C> Che ck Digit T ra n smission UPC-A Che ck Digit T ra n smission <ON> OFF UPC-E Che ck Digit T ra n smission <ON> OFF EAN-8 Che ck Digit T ra n smission <ON> OFF EAN-13 Che ck Digit T ra n smission <ON> O ...

  • IC Intracom 460835 - page 28

    26 5.3 Code 39 Para meters A> T ype of Code <Standard> Full ASCII Itali a n Pharma cy/Code 32 <OFF> Itali a n Pharma cy/ Code 32 ON B> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit C> Output Start/Stop Character Enable < ...

  • IC Intracom 460835 - page 29

    27 D> Decode Asterisk Enable <Disable> E> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps ...

  • IC Intracom 460835 - page 30

    28 5.4 Code 128 Para meters A> Re a ding T ype UCC/EAN-128 Enable <UCC/EAN-128 Disa ble> <Enable']C1'Code Format> Disa ble']C1'Code Format <En a ble Code128 Group Separators (GS)> Disa ble Code128 Group Se parators (GS) B> Che ck Digit T ra n smission Do Not Calculate Che ck Digit Calculate Check Digit &a ...

  • IC Intracom 460835 - page 31

    29 D> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps 1 - 3 to set additional lengths. <V ari a ...

  • IC Intracom 460835 - page 32

    30 5.5 Interle ave 25 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit B> Set Up Number of Character <Even> Odd C> Brazilian Banking Code <Disable> Enable % 0 G N3 % 0 G N7 % 0 G N5 % 0 G 8 8 % 0 G 8 0 % 0 G 4 0 ...

  • IC Intracom 460835 - page 33

    31 D> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps 1 - 3 to set additional lengths. <V ari a ...

  • IC Intracom 460835 - page 34

    32 5.6 Industri al 25 Para meters A> Reading type IA T A25 En a ble <Disable> B> Che ck Digit T ra n smission <Do Not Calculate Che ck Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit C> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sire ...

  • IC Intracom 460835 - page 35

    33 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 H1 + % 4 H0 0 % 4 H0 0 % 4 H0 1 % 4 H0 2 % 2 + - / % 2 C3 + ...

  • IC Intracom 460835 - page 36

    34 5.7 M atrix 25 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix ...

  • IC Intracom 460835 - page 37

    35 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 I 1 + % 4 I 0 0 % 4 I 0 0 % 4 I 0 1 % 4 I 0 2 % 2 + - / % 2 C4 + ...

  • IC Intracom 460835 - page 38

    36 5.8 CODABAR/N W7 Para meters A> Set Up Start/Stop Characters Upon T ra n smission ON <OFF> B> T ra n smission T ype of Start/Stop <A/B/C/D> <Start> <A/B/C/D> <Stop> A Start A Stop B Start B Stop C Start C Stop D Start D Stop % 0 J H1 % 0 J H0 % 0 4 V F % 0 4 F F % 0 4 V 1 % 0 4 F 1 % 0 4 V 2 % 0 4 F 2 % 0 4 V ...

  • IC Intracom 460835 - page 39

    37 C> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps 1 - 3 to set additional lengths. <V ari a ...

  • IC Intracom 460835 - page 40

    38 5.9 Code 93 Para meters A> Che ck Digit T ra n smission <Calculate Check 2 Digits & Not T ra n smit> Do Not Calculate Che ck Digit B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the ...

  • IC Intracom 460835 - page 41

    39 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 K1 + % 4 K0 0 % 4 K0 0 % 4 K0 1 % 4 K0 2 % 2 + - / % 2 C6 + ...

  • IC Intracom 460835 - page 42

    40 5.10 Code 1 1 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Check 1 Digit & T ra n smit Calculate Che ck 1 Digit & Not T ra n smit Calculate Check 2 Digits & T ra n smit Calculate Che ck 2 Digits & Not T ra n smit B> Set Up Code Length T o set the f ixed length: 1. Sca n the &quo ...

  • IC Intracom 460835 - page 43

    41 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 L 1 + % 4 L 0 0 % 4 L 0 0 % 4 L 0 1 % 4 L 0 2 % 2 + - / % 2 C7 + ...

  • IC Intracom 460835 - page 44

    42 5.1 1 MSI/PLESSEY Code Para meters A> Che ck Digit T ra n smission Do Not Calculate Check Digit Calculate Che ck Digit & T ra n smit <Calculate Che ck Digit & Not T ra n smit> B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in ...

  • IC Intracom 460835 - page 45

    43 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 N1 + % 4 N0 0 % 4 N0 0 % 4 N0 1 % 4 N0 2 % 2 + - / % 2 C9 + ...

  • IC Intracom 460835 - page 46

    44 5.12 Code 2 of 6 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Che ck Digit> Calculate Check Digit & T ra n smit> Calculate Che ck Digit & Not T ra n smit B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Ap ...

  • IC Intracom 460835 - page 47

    45 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 2 + - / % 4 P1 + % 4 P0 0 % 4 P0 1 % 4 P0 0 % 4 P0 2 % 2 CB+ ...

  • IC Intracom 460835 - page 48

    46 5.13 LCD25 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Che ck Digit> Calculate Che ck Digit & T ra n smit Calculate Check Digit & Not T ra n smit B> Setup Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, s ...

  • IC Intracom 460835 - page 49

    47 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2st Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 2 + - / % 4 Q 1 + % 4 Q 0 0 % 4 Q 0 1 % 4 Q 0 0 % 4 Q 0 2 % 2 CC + ...

  • IC Intracom 460835 - page 50

    48 5.14 T ele pen Para meters A> T ype of Code <Full ASCll Mode> % 0 T 8 0 Compre ssed Numeric Mode % 0 T 8 8 B> Che ck Digit T ra n smission Do Not Calculate Che ck Digit % 0 T N 3 Calculate Check Digit & T ra n smit <Calculate Che ck Digit & Not T ra n smit> % 0 T N 7 % 0 T N 5 C> Set Up Code Length T o set the f ixed ...

  • IC Intracom 460835 - page 51

    49 <V ari a ble> % 4 T 1 + Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 T 0 0 % 4 T 0 1 % 4 T 0 0 % 4 T 0 2 % 2 % + - / % 2 CF + ...

  • IC Intracom 460835 - page 52

    50 5.15 GS1 Databar(RSS Code) A> GS1 DataBar Omnidirectional ON <T ra n smit Che ck Digit> % 0 UN 7 Don't T ra n smit Che ck Digit % 0 UN 5 <T ra n smit Application ID> % 0 U8 8 Don't T ra n smit Application ID % 0 U8 0 T ra n smit Symbology ID % 0 U4 4 <Don't T ra n smit Symbology ID> % 0 U4 0 B> GS1 DataBar ...

  • IC Intracom 460835 - page 53

    51 <T ra n smit Application ID> % 0 V8 8 Don't T ra n smit Application ID % 0 V8 0 T ra n smit Symbology ID % 0 V4 4 <Don't T ra n smit Symbology ID> % 0 V4 0 C> GS1 DataBar Expa nded Para meters T ra n smit Symbology ID % 0 W 4 4 <Don't T ra n smit Symbology ID> % 0 W 4 0 ...

  • IC Intracom 460835 - page 54

    52 Ch.6 M iscella neous Para meters 6.1 La nguage Sele ction <US English> UK English Itali a n Spa nish French Germa n Swedish Switzerla nd Hungari a n Ja pa ne se % 0 Z V0 % 0 Z V1 % 0 Z V2 % 0 Z V3 % 0 Z V4 % 0 Z V5 % 0 Z V6 % 0 Z V7 % 0 Z V8 % 0 Z V9 ...

  • IC Intracom 460835 - page 55

    53 Belgium Portuguese Denmark Netherla nds T urkey Reserved2 % 0 Z VA % 0 Z VB % 0 Z VC % 0 Z VD % 0 Z VE % 0 Z VF ...

  • IC Intracom 460835 - page 56

    54 6.2 Bar Code ID ON <OFF> Default W ith this function ON, a le a ding chara cter will be a dded to the output string while sca nning code, user may refer to the following table to know what kind of bar code is be ing sca nned. Ple a se refer to the ta ble below f or matching code ID of codes read in. Code T ype ID Code T ype ID UPC-A A UPC- ...

  • IC Intracom 460835 - page 57

    55 UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY % 9 1 A + % 9 1 B + % 9 1 Y + % 9 1 Z + % 9 1 E + % 9 1 F + % 9 1 G + % 9 1 H+ % 9 1 I + % 9 1 J + % 9 1 K + % 9 1 L + % 9 1 M + % 9 1 N+ ...

  • IC Intracom 460835 - page 58

    56 Code 2 of 6 T ele pen LCD25 RSS-14 RSS Limited RSS Expa nded Reserved5 Reserved6 % 9 1 P + % 9 1 R+ % 9 1 S + % 9 1 T + % 9 1 Q + % 9 1 U + % 9 1 V+ % 9 1 W + ...

  • IC Intracom 460835 - page 59

    57 6.3 Reading Level Bar Equals High <Bar Equals Low> 6.4 Accuracy <1 Time> 2 T i me s 3 T i me s 4 T i me s 6.5 Buzzer Bee p T one <High> Medium Low Off 6.6 LED Control(SV700 only) <ON> OFF % 0 1 3 0 % 0 1 3 1 % 0 1 3 2 % 0 1 3 3 % 0 1 J 3 % 0 1 J 2 % 0 1 J 1 % 0 1 J 0 % 0 3 I 0 % 0 3 I 2 % 0 9 O 8 % 0 9 O 0 ...

  • IC Intracom 460835 - page 60

    58 6.7 Sensitivity of Continuous Read ing Mode A> Quick Setting: <Fa st> Slow B> Sa me Code Delay Re a ding Interval Following code sequences represent the length of ti me bef ore a barcode ca n be re sca nned at continuous a nd fla sh re a ding mode. The value ca n be def ined from 1-50 a nd they re pre sent 100ms to 5 se conds in 100m ...

  • IC Intracom 460835 - page 61

    59 6.9 Reverse Output Characters <Disable> % 0 3 H0 Enable 6.10 Setup Deletion T o setup the deletion of output chara cters: 1. Sca n the la bel of the de sired set below . 2. Sca n the la bel of the de sired symbology . 3. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the de sired position to be delete ...

  • IC Intracom 460835 - page 62

    60 B> Symbologies Selection UPC-A UPC-E EAN-13/JAN-13/ISBN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY % 8 1 A + % 8 1 B + % 8 1 Y + % 8 1 Z + % 8 1 E + % 8 1 F + % 8 1 J + % 8 1 G + % 8 1 H+ % 8 1 I + % 8 1 K + % 8 1 L + % 8 1 M + % 8 1 N+ ...

  • IC Intracom 460835 - page 63

    61 Code 2 of 6 T ele pen LCD25 RSS-14 RSS Limited RSS Expa nded All Code s None C> Character Position to be Deleted 1. De ci mal V alue (Appendix A) 2. Complete D> Number of Chara cters to be Deleted 1. De ci mal V alue (Appendix A) 2. Complete % 8 1 P + % 8 1 S + % 8 2 0 + % 8 3 0 + % 8 1 4 + % 8 1 T + % 8 1 Q + % 8 1 U + % 8 1 V+ % 8 1 W + ...

  • IC Intracom 460835 - page 64

    62 6.1 1 Setup Insertion T o setup the in sertion of output chara cters: 1. Sca n the la bel of the de sired set. 2. Sca n the la bel of the de sired symbology . 3. Go to the De ci mal V alue T a ble s in Appendix A, sca n label(s) that represents the desired position to be inserted. 4. Sca n the "Complete" la bel of "Chara cter Posi ...

  • IC Intracom 460835 - page 65

    63 B> Symbologies Selection UPC-A UPC-E EAN-13/JAN-13/ISBN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY % 5 1 A + % 5 1 B + % 5 1 Y + % 5 1 Z + % 5 1 E + % 5 1 F + % 5 1 G + % 5 1 J + % 5 1 H+ % 5 1 I + % 5 1 K + % 5 1 L + % 5 1 M + % 5 1 N+ ...

  • IC Intracom 460835 - page 66

    64 Code 2 of 6 T ele pen LCD25 RSS-14 RSS Limited RSS Expa nded All Code s None C> Character Position to be Inserted 1. De ci mal V alue (Appendix A) 2. Complete D> Characters to be Inserted 1. ASCII T a ble (Appendix B) 2. Complete % 5 2 0 + % 5 3 0 + % 5 1 4 + % 5 1 S + % 5 1 P+ % 5 1 T + % 5 1 Q + % 5 1 U + % 5 1 V+ % 5 1 W + ...

  • IC Intracom 460835 - page 67

    65 6.12 Setup IR Sensor (LG303 only) <Disable> Enable % 0 XH0 % 0 XH1 ...

  • IC Intracom 460835 - page 68

    66 Appendix A De ci mal V alue T a ble 8 0 1 2 3 4 5 6 7 9 ...

  • IC Intracom 460835 - page 69

    67 Appendix B ASCII T a ble NULL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 0 3 0 0 0 2 0 1 0 4 0 5 0 6 0 7 0 8 0 9 0A 0B 0C 0D 0E 0 F 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1A 1B 1C 1D 1E 1 F ...

  • IC Intracom 460835 - page 70

    68 SP ACE ! " # $ % & ' ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2A 2B 2C 2D 2E 2 F 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3A 3B 3C 3D 3E 3 F ...

  • IC Intracom 460835 - page 71

    69 @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ] ^ _ 4 0 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4A 4B 4C 4E 4D 4 F 5 0 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 5A 5B 5C 5D 5E 5 F ...

  • IC Intracom 460835 - page 72

    70 ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL 6 0 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 9 6A 6B 6C 6D 6E 6 F 7 0 7 1 7 2 7 3 7 4 7 5 7 6 7 7 7 8 7 9 7A 7B 7C 7D 7E 7 F ...

  • IC Intracom 460835 - page 73

    71 Appendix C Function Key T a ble F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F1 1 F12 Insert Delete Home Page Up Page Down End Left Right Up Down C 1 C 0 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C 9 C A C B C C C D C E C F D 0 D 1 D 2 D 3 D 4 D 5 ...

  • IC Intracom 460835 - page 74

    %$ + / 0 %$ + / 1 %$ + / 2 %$ + / 3 %$ + / 4 %$ + / 6 %$ + / 5 Save Para meters Recall Stored Para meters Set All Defaults Start Configuration End Configuration Abort Configuration V ersion Information Ver 3.8 a 0145-85E00J1 ...

Fabricante IC Intracom Categoría Barcode readers

Los documentos del dispositivo IC Intracom 460835 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos IC Intracom
- manuales de instrucciones 460835
- hojas de producto IC Intracom
- folletos informativos
- o etiquetas energéticas IC Intracom 460835
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones IC Intracom 460835.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje IC Intracom 460835, instrucciones de servicio, instrucciones cortas o instrucciones de usuario IC Intracom 460835. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto IC Intracom 460835.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo IC Intracom 460835, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar IC Intracom 460835. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de IC Intracom 460835.

El manual de instrucciones completo de IC Intracom debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual IC Intracom 460835 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice IC Intracom 460835, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de IC Intracom 460835 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo IC Intracom 460835 - que deben facilitarnos los primeros pasos durante el uso de IC Intracom 460835
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con IC Intracom 460835
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de IC Intracom 460835 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de IC Intracom 460835?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con IC Intracom 460835, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con IC Intracom 460835 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)