Documents that we receive from a manufacturer of a IC Intracom 460835 can be divided into several groups. They are, among others:
- IC Intracom technical drawings
- 460835 manuals
- IC Intracom product data sheets
- information booklets
- or energy labels IC Intracom 460835
All of them are important, but the most important information from the point of view of use of the device are in the user manual IC Intracom 460835.
- UserManuals.org
- IC Intracom
- IC Intracom Barcode readers
- IC Intracom 460835
Manual IC Intracom 460835
Go to site of 74
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- 31
- 32
- 33
- 34
- 35
- 36
- 37
- 38
- 39
- 40
- 41
- 42
- 43
- 44
- 45
- 46
- 47
- 48
- 49
- 50
- 51
- 52
- 53
- 54
- 55
- 56
- 57
- 58
- 59
- 60
- 61
- 62
- 63
- 64
- 65
- 66
- 67
- 68
- 69
- 70
- 71
- 72
- 73
- 74
Summary
-
IC Intracom 460835 - page 1
BAR CODE BAR CODE ...
-
IC Intracom 460835 - page 2
Progra mming Menu V3.8 a Notice The ma nufa cturer shall not be li a ble f or te chnical or editorial errors or omissions contained herein; nor f or incidental or con sequenti al da mage s in conne ction with the furnishing,perf orma nce or use of use the publication. ...
-
IC Intracom 460835 - page 3
1 Contents Cha pter 1 Description 1.1 Notice ....................................................... 3 1.2 Introduction ........................................... 4 1.3 Codes Read ........................................... 4 1.4 Installation .............................................. 4 1.5 Pin Assign ment ..................................... ...
-
IC Intracom 460835 - page 4
2 5.12 Code 2 of 6 Para meters ......................... 44 5.13 LCD 25 Para meters ............................. 46 5.14 T ele pen Para meters ............................. 48 5.15 GS1 DataBar (RSS Code) ........................ 50 Cha pter 6 M iscella neous Para meters 6.1 La nguage Sele ction .............................. 52 6.2 Bar Code ID ... ...
-
IC Intracom 460835 - page 5
3 Cha pter 1 De scri ption 1.1 General Tha nk you f or purcha sing this barcode sca nner with a n a dva nced a nd versatile de coder .The de coder works with variety of barcode types,reading devices, a nd computer interfa ce s.It discri min ate s over twenty different symbologies automatically. This menu provide s a n e a sy way to conf igure the d ...
-
IC Intracom 460835 - page 6
4 1.2 Introduction The De coder is a n a dva nced a nd versatile de coding fa cility f or barcoding syste ms .It work s with variety of bar code types, reading devices, a nd computer interfa ce s. It discri min ate s a bout twenty different symbologies automatically. This menu provide a n e a sy way to conf ig the de coding option s a nd interfa ce ...
-
IC Intracom 460835 - page 7
5 Power supply for RS-232C scanner– There are 3 ways to supplying the power, use ex- ternal +5V power supply, use optional power cable (KBDC) which ta king the power from KB wedge or if the host supports +5V power from pin 9. Installing the scanner to the Host System – 1. Turn off the host system. 2. Connect the power if needed. 3. Connect to t ...
-
IC Intracom 460835 - page 8
6 1.5 Pin Assignment A> Input Port for Mini Decoder DB 9 Male Pin No. W a nd / CCD / Slot Reader La ser Sca nner 1 N.C. S.O.S. 2 DA T A DA T A 3 N.C. N.C. 4 N.C. N.C. 5 N.C. TRIGGER 6 N.C. P. E. 7 GND GND 8 SHIELD SHIELD 9 +5V +5V B> Output Port 1. PC Keyboard Output DIN 5 MALE DIN 5 FEMALE Pin No. Function Pin No. Function 1 HOST CLK 1 KB CL ...
-
IC Intracom 460835 - page 9
7 6 1 5 9 1 2 4 3 1 3 2 4 6 7 8 5 2 1 3 4 2 5 1 3 8 7 6 4 6 1 5 9 2. RS-232 Output DB 9 Female Pin No. Function 2 TXD 3 RXD 5 GND 7 CTS 8 RTS Power Lead Vcc (+5V) 3. W AND Emulation Output DB 9 Female Pin No. Function 2 DA T A 7 GND 9 Vcc (+5V) 4. ADB Interface MiniDIN 4 MALE MiniDIN 4 FEMALE Pin No. Function Pin No. Function 1 ADB 1 ADB 3 Vcc 3 Vc ...
-
IC Intracom 460835 - page 10
8 Cha pter 2 Conf iguration - General 2.1 Flow Chart ...
-
IC Intracom 460835 - page 11
9 2.2 Loop of Progra mming The philosophy of progra mming para meters ha s been shown on the flow chart of 2.1. Ba sically user should 1.Sca n Start of Conf iguration. 2.Sca n all ne ce ssary la bels f or para meters that meet a pplication s. 3.Sca n End of Conf iguration to end the progra mming. 4.T o perma nently save the settings you progra mmed ...
-
IC Intracom 460835 - page 12
10 % $ + / 0 % $ + / 1 % $ + / 2 % $ + / 3 % $ + / 4 % $ + / 6 % $ + / 5 2.4 Main Page of Configuration Save Para meters Recall Stored Para meters Set All Defaults Start Configuration End Configuration Abort Configuration V ersion Inf ormation Save Para meters - The para meter settings will be saved perma nently . Re call Stored Para meters - Re pl ...
-
IC Intracom 460835 - page 13
1 1 Cha pter 3 Interf a ce a nd Re a ding Mode Sele ction 3.1 Interface Selection <Keyboard Mode> RS232 Mode WAND Emulation USB Mode 3.2 Memory Function<HC102M Only> <Enable> Disa ble % 0 0 U0 % 0 0 U8 % 0 0 M 2 % 0 XI 2 % 0 XI 0 % 0 XO 8 ...
-
IC Intracom 460835 - page 14
12 3.3 Reading Mode Selection <Good Read OFF> Trigger ON/OFF Continuous/Trigger OFF T e sting Continuous/Auto Power On Fla sh Fla sh/Auto Power On Reserved1 Re served 2 ( Auto Sen se Option) Reserved3 Reserved4 Reserved5 % 0 2 7 1 % 0 2 7 0 % 0 2 7 2 % 0 2 7 5 % 0 2 7 3 % 0 2 7 4 % 0 2 7 6 % 0 2 7 7 % 0 9 F 8 % 0 9 F 9 % 0 9 F A % 0 9 F B ...
-
IC Intracom 460835 - page 15
13 Ch.4 Communication Para meters 4.1 RS232 Communication Para m eters A> Set Up BAUD Rate 1200 2400 4800 <9600> 19200 38400 B> Set Up Data Bits 7 Data Bits <8 Data Bits> C> Set Up Stop Bits <1 Bit> 2 Bits % 0 Y8 0 % 0 Y8 8 % 0 Y7 1 % 0 Y7 2 % 0 Y7 3 % 0 Y7 7 % 0 Y7 4 % 0 YO 8 % 0 YO 0 % 0 Y7 5 ...
-
IC Intracom 460835 - page 16
14 D> Set Up Parity <None> Even Odd Mark Spa ce E> Ha ndsha king RTS/CTS Enable <RTS/CTS Disa ble> ACK/NAK Enable <ACK/NAK Disa ble> XON/XOFF Enable <XON/XOFF Disa ble> % 0 YN7 % 0 YN2 % 0 YN3 % 0 YN1 % 0 YN0 % 0 1 8 8 % 0 1 8 0 % 0 1 4 4 % 0 1 4 0 % 0 3 K 4 % 0 3 K 0 ...
-
IC Intracom 460835 - page 17
15 4.2 Keyboard W edge Mode Para meters A> T ermin al T ype <IBM PC/A T , PS/2> IBM PC/XT IBM PS/2 25, 30 NEC 9800 Apple De s ktop Bus( ADB ) IBM 5550 IBM 122 Key (1) IBM 102 Key IBM 122 Key (2) Reserved 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 % 0 Z F 0 % 0 Z F 1 % 0 Z F 2 % 0 Z F 3 % 0 Z F 4 % 0 Z F 5 % 0 Z F 6 % 0 Z F 7 % 0 Z F 8 % ...
-
IC Intracom 460835 - page 18
16 B> Upper/Lower Ca se <No Cha nge> Upper Ca se Lower Ca se C> Ca pslock Dete ction Enable <Disable> D> Send Chara cter by AL T Method Enable <Disable> E>Sele ct Numerical Pa d ON <OFF> % 0 3 3 0 % 0 3 3 1 % 0 3 3 2 % 0 X8 8 % 0 X8 0 % 0 3 O 8 % 0 3 O 0 % 0 1 K4 % 0 1 K0 ...
-
IC Intracom 460835 - page 19
17 4.3 Output Chara cters Para meters A> Sele ct T ermin ator <CR+LF> None CR LF Spa ce HT(T AB) STX-ETX % 7 S0 + % 7 S2 + % 7 S4 + % 7 S5 + % 7 S7 + % 7 S1 + % 7 S3 + ...
-
IC Intracom 460835 - page 20
18 B> Time-out Between Characters <0 ms> 5 ms 10 ms 25 ms 50 ms 100 ms 200 ms 300 ms % 0 0 7 0 % 0 0 7 1 % 0 0 7 2 % 0 0 7 3 % 0 0 7 4 % 0 0 7 5 % 0 0 7 6 % 0 0 7 7 ...
-
IC Intracom 460835 - page 21
19 4.4 W a nd Emulation Mode Para meters A> TTL Level Re pre sentation <Bar Equals High> Bar Equals Low B> Sca n Speed Sele ction <Fa st> Slow C> Output Format Selection <Output a s Code 39> Output a s Code 39 Full ASCII Output a s Origin al Code Format % 0 2 K 4 % 0 2 K 0 % 0 2 8 8 % 0 2 8 0 % 0 2 O 8 % 0 2 O 0 % 0 XK 4 ...
-
IC Intracom 460835 - page 22
20 Ch.5 Bar Code s & Others 5.1 Symbologies Selection UPC-A <ON> OFF UPC-E <ON> OFF EAN-13/JAN-13/ISBN-13 <ON> OFF EAN-8/JAN-8 <ON> OFF CODE 39 <ON> OFF CODE 128 <ON> OFF CODABAR/N W7 <ON> OFF % 0 A4 4 % 0 A4 0 % 0 BO 8 % 0 BO 0 % 0 A2 2 % 0 A2 0 % 0 A1 1 % 0 A1 0 % 0 EO 8 % 0 EO 0 % 0 F O 8 % 0 F O 0 % ...
-
IC Intracom 460835 - page 23
21 Interleave 25 <ON> OFF Industrial 25 ON <OFF> Matrix 25 ON <OFF> CODE 93 ON <OFF> CODE 1 1 ON <OFF> China Postage ON <OFF> MSI/PLESSEY ON <OFF> % 0 G O 8 % 0 G O 0 % 0 HO 8 % 0 HO 0 % 0 I O 8 % 0 I O 0 % 0 KO 8 % 0 KO 0 % 0 L O 8 % 0 L O 0 % 0 M O 8 % 0 M O 0 % 0 NO 8 % 0 NO 0 ...
-
IC Intracom 460835 - page 24
22 Code 2 of 6 ON <OFF> LCD25 ON <OFF> T ele pen ON <OFF> Reserved5 ON <OFF> Reserved6 ON <OFF> % 0 PO 8 % 0 PO 0 % 0 Q O 8 % 0 Q O 0 % 0 RO 8 % 0 RO 0 % 0 SO 8 % 0 SO 0 % 0 T O 8 % 0 T O 0 ...
-
IC Intracom 460835 - page 25
23 % 0 UO 8 % 0 UO 0 % 0 VO 8 % 0 VO 0 % 1 A/ + % 0 W O 8 % 0 W O 0 GS1 DataBar Omnidire ction al ON <OFF> GS1 DataBar Li mited ON <OFF> GS1 DataBar Expa nded ON <OFF> Sele ct All Bar Code s ...
-
IC Intracom 460835 - page 26
24 5.2 UPC/EAN/JAN Para meters A> Re a ding T ype UPCA=EAN13 ON UPCA=EAN13<OFF> ISBN-10 Enable ISBN-13 <Enable> ISSN Enable ISSN <Disable> Decode with Supplement <Autodiscriminate Supplement> Expa nd UPC-E Enable Expa nd UPC-E <Disable> EAN8=EAN13 Enable EAN8=EAN13 <Disable> GTIN Format Enable GTIN Format < ...
-
IC Intracom 460835 - page 27
25 B> Supplementals Set Up <Not T ra n smit> T ra n smit 2 Code T ra n smit 5 Code T ra n smit 2&5 Code C> Che ck Digit T ra n smission UPC-A Che ck Digit T ra n smission <ON> OFF UPC-E Che ck Digit T ra n smission <ON> OFF EAN-8 Che ck Digit T ra n smission <ON> OFF EAN-13 Che ck Digit T ra n smission <ON> O ...
-
IC Intracom 460835 - page 28
26 5.3 Code 39 Para meters A> T ype of Code <Standard> Full ASCII Itali a n Pharma cy/Code 32 <OFF> Itali a n Pharma cy/ Code 32 ON B> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit C> Output Start/Stop Character Enable < ...
-
IC Intracom 460835 - page 29
27 D> Decode Asterisk Enable <Disable> E> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps ...
-
IC Intracom 460835 - page 30
28 5.4 Code 128 Para meters A> Re a ding T ype UCC/EAN-128 Enable <UCC/EAN-128 Disa ble> <Enable']C1'Code Format> Disa ble']C1'Code Format <En a ble Code128 Group Separators (GS)> Disa ble Code128 Group Se parators (GS) B> Che ck Digit T ra n smission Do Not Calculate Che ck Digit Calculate Check Digit &a ...
-
IC Intracom 460835 - page 31
29 D> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps 1 - 3 to set additional lengths. <V ari a ...
-
IC Intracom 460835 - page 32
30 5.5 Interle ave 25 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit B> Set Up Number of Character <Even> Odd C> Brazilian Banking Code <Disable> Enable % 0 G N3 % 0 G N7 % 0 G N5 % 0 G 8 8 % 0 G 8 0 % 0 G 4 0 ...
-
IC Intracom 460835 - page 33
31 D> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps 1 - 3 to set additional lengths. <V ari a ...
-
IC Intracom 460835 - page 34
32 5.6 Industri al 25 Para meters A> Reading type IA T A25 En a ble <Disable> B> Che ck Digit T ra n smission <Do Not Calculate Che ck Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit C> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sire ...
-
IC Intracom 460835 - page 35
33 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 H1 + % 4 H0 0 % 4 H0 0 % 4 H0 1 % 4 H0 2 % 2 + - / % 2 C3 + ...
-
IC Intracom 460835 - page 36
34 5.7 M atrix 25 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Che ck Digit & T ra n smit Calculate Che ck Digit & Not T ra n smit B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix ...
-
IC Intracom 460835 - page 37
35 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 I 1 + % 4 I 0 0 % 4 I 0 0 % 4 I 0 1 % 4 I 0 2 % 2 + - / % 2 C4 + ...
-
IC Intracom 460835 - page 38
36 5.8 CODABAR/N W7 Para meters A> Set Up Start/Stop Characters Upon T ra n smission ON <OFF> B> T ra n smission T ype of Start/Stop <A/B/C/D> <Start> <A/B/C/D> <Stop> A Start A Stop B Start B Stop C Start C Stop D Start D Stop % 0 J H1 % 0 J H0 % 0 4 V F % 0 4 F F % 0 4 V 1 % 0 4 F 1 % 0 4 V 2 % 0 4 F 2 % 0 4 V ...
-
IC Intracom 460835 - page 39
37 C> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the length to be read. 3. Sca n the "Complete" la bel of the de sired set. Repeat the steps 1 - 3 to set additional lengths. <V ari a ...
-
IC Intracom 460835 - page 40
38 5.9 Code 93 Para meters A> Che ck Digit T ra n smission <Calculate Check 2 Digits & Not T ra n smit> Do Not Calculate Che ck Digit B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the ...
-
IC Intracom 460835 - page 41
39 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 K1 + % 4 K0 0 % 4 K0 0 % 4 K0 1 % 4 K0 2 % 2 + - / % 2 C6 + ...
-
IC Intracom 460835 - page 42
40 5.10 Code 1 1 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Check Digit> Calculate Check 1 Digit & T ra n smit Calculate Che ck 1 Digit & Not T ra n smit Calculate Check 2 Digits & T ra n smit Calculate Che ck 2 Digits & Not T ra n smit B> Set Up Code Length T o set the f ixed length: 1. Sca n the &quo ...
-
IC Intracom 460835 - page 43
41 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 L 1 + % 4 L 0 0 % 4 L 0 0 % 4 L 0 1 % 4 L 0 2 % 2 + - / % 2 C7 + ...
-
IC Intracom 460835 - page 44
42 5.1 1 MSI/PLESSEY Code Para meters A> Che ck Digit T ra n smission Do Not Calculate Check Digit Calculate Che ck Digit & T ra n smit <Calculate Che ck Digit & Not T ra n smit> B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in ...
-
IC Intracom 460835 - page 45
43 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 N1 + % 4 N0 0 % 4 N0 0 % 4 N0 1 % 4 N0 2 % 2 + - / % 2 C9 + ...
-
IC Intracom 460835 - page 46
44 5.12 Code 2 of 6 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Che ck Digit> Calculate Check Digit & T ra n smit> Calculate Che ck Digit & Not T ra n smit B> Set Up Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Ap ...
-
IC Intracom 460835 - page 47
45 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 2 + - / % 4 P1 + % 4 P0 0 % 4 P0 1 % 4 P0 0 % 4 P0 2 % 2 CB+ ...
-
IC Intracom 460835 - page 48
46 5.13 LCD25 Para meters A> Che ck Digit T ra n smission <Do Not Calculate Che ck Digit> Calculate Che ck Digit & T ra n smit Calculate Check Digit & Not T ra n smit B> Setup Code Length T o set the f ixed length: 1. Sca n the "Begin" la bel of the de sired set. 2. Go to the De ci mal V alue T a ble s in Appendix A, s ...
-
IC Intracom 460835 - page 49
47 <V ari a ble> Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2st Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 2 + - / % 4 Q 1 + % 4 Q 0 0 % 4 Q 0 1 % 4 Q 0 0 % 4 Q 0 2 % 2 CC + ...
-
IC Intracom 460835 - page 50
48 5.14 T ele pen Para meters A> T ype of Code <Full ASCll Mode> % 0 T 8 0 Compre ssed Numeric Mode % 0 T 8 8 B> Che ck Digit T ra n smission Do Not Calculate Che ck Digit % 0 T N 3 Calculate Check Digit & T ra n smit <Calculate Che ck Digit & Not T ra n smit> % 0 T N 7 % 0 T N 5 C> Set Up Code Length T o set the f ixed ...
-
IC Intracom 460835 - page 51
49 <V ari a ble> % 4 T 1 + Fix Length (2 Sets A vaila ble) 1. 1st Set Begin 2. De ci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. De ci mal V alue (Appendix A) 3. 2nd Set Complete Minimum Length 1. Begin 2. De ci mal V alue (Appendix A) 3. Complete % 4 T 0 0 % 4 T 0 1 % 4 T 0 0 % 4 T 0 2 % 2 % + - / % 2 CF + ...
-
IC Intracom 460835 - page 52
50 5.15 GS1 Databar(RSS Code) A> GS1 DataBar Omnidirectional ON <T ra n smit Che ck Digit> % 0 UN 7 Don't T ra n smit Che ck Digit % 0 UN 5 <T ra n smit Application ID> % 0 U8 8 Don't T ra n smit Application ID % 0 U8 0 T ra n smit Symbology ID % 0 U4 4 <Don't T ra n smit Symbology ID> % 0 U4 0 B> GS1 DataBar ...
-
IC Intracom 460835 - page 53
51 <T ra n smit Application ID> % 0 V8 8 Don't T ra n smit Application ID % 0 V8 0 T ra n smit Symbology ID % 0 V4 4 <Don't T ra n smit Symbology ID> % 0 V4 0 C> GS1 DataBar Expa nded Para meters T ra n smit Symbology ID % 0 W 4 4 <Don't T ra n smit Symbology ID> % 0 W 4 0 ...
-
IC Intracom 460835 - page 54
52 Ch.6 M iscella neous Para meters 6.1 La nguage Sele ction <US English> UK English Itali a n Spa nish French Germa n Swedish Switzerla nd Hungari a n Ja pa ne se % 0 Z V0 % 0 Z V1 % 0 Z V2 % 0 Z V3 % 0 Z V4 % 0 Z V5 % 0 Z V6 % 0 Z V7 % 0 Z V8 % 0 Z V9 ...
-
IC Intracom 460835 - page 55
53 Belgium Portuguese Denmark Netherla nds T urkey Reserved2 % 0 Z VA % 0 Z VB % 0 Z VC % 0 Z VD % 0 Z VE % 0 Z VF ...
-
IC Intracom 460835 - page 56
54 6.2 Bar Code ID ON <OFF> Default W ith this function ON, a le a ding chara cter will be a dded to the output string while sca nning code, user may refer to the following table to know what kind of bar code is be ing sca nned. Ple a se refer to the ta ble below f or matching code ID of codes read in. Code T ype ID Code T ype ID UPC-A A UPC- ...
-
IC Intracom 460835 - page 57
55 UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY % 9 1 A + % 9 1 B + % 9 1 Y + % 9 1 Z + % 9 1 E + % 9 1 F + % 9 1 G + % 9 1 H+ % 9 1 I + % 9 1 J + % 9 1 K + % 9 1 L + % 9 1 M + % 9 1 N+ ...
-
IC Intracom 460835 - page 58
56 Code 2 of 6 T ele pen LCD25 RSS-14 RSS Limited RSS Expa nded Reserved5 Reserved6 % 9 1 P + % 9 1 R+ % 9 1 S + % 9 1 T + % 9 1 Q + % 9 1 U + % 9 1 V+ % 9 1 W + ...
-
IC Intracom 460835 - page 59
57 6.3 Reading Level Bar Equals High <Bar Equals Low> 6.4 Accuracy <1 Time> 2 T i me s 3 T i me s 4 T i me s 6.5 Buzzer Bee p T one <High> Medium Low Off 6.6 LED Control(SV700 only) <ON> OFF % 0 1 3 0 % 0 1 3 1 % 0 1 3 2 % 0 1 3 3 % 0 1 J 3 % 0 1 J 2 % 0 1 J 1 % 0 1 J 0 % 0 3 I 0 % 0 3 I 2 % 0 9 O 8 % 0 9 O 0 ...
-
IC Intracom 460835 - page 60
58 6.7 Sensitivity of Continuous Read ing Mode A> Quick Setting: <Fa st> Slow B> Sa me Code Delay Re a ding Interval Following code sequences represent the length of ti me bef ore a barcode ca n be re sca nned at continuous a nd fla sh re a ding mode. The value ca n be def ined from 1-50 a nd they re pre sent 100ms to 5 se conds in 100m ...
-
IC Intracom 460835 - page 61
59 6.9 Reverse Output Characters <Disable> % 0 3 H0 Enable 6.10 Setup Deletion T o setup the deletion of output chara cters: 1. Sca n the la bel of the de sired set below . 2. Sca n the la bel of the de sired symbology . 3. Go to the De ci mal V alue T a ble s in Appendix A, sca n la bel(s) that re pre sents the de sired position to be delete ...
-
IC Intracom 460835 - page 62
60 B> Symbologies Selection UPC-A UPC-E EAN-13/JAN-13/ISBN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY % 8 1 A + % 8 1 B + % 8 1 Y + % 8 1 Z + % 8 1 E + % 8 1 F + % 8 1 J + % 8 1 G + % 8 1 H+ % 8 1 I + % 8 1 K + % 8 1 L + % 8 1 M + % 8 1 N+ ...
-
IC Intracom 460835 - page 63
61 Code 2 of 6 T ele pen LCD25 RSS-14 RSS Limited RSS Expa nded All Code s None C> Character Position to be Deleted 1. De ci mal V alue (Appendix A) 2. Complete D> Number of Chara cters to be Deleted 1. De ci mal V alue (Appendix A) 2. Complete % 8 1 P + % 8 1 S + % 8 2 0 + % 8 3 0 + % 8 1 4 + % 8 1 T + % 8 1 Q + % 8 1 U + % 8 1 V+ % 8 1 W + ...
-
IC Intracom 460835 - page 64
62 6.1 1 Setup Insertion T o setup the in sertion of output chara cters: 1. Sca n the la bel of the de sired set. 2. Sca n the la bel of the de sired symbology . 3. Go to the De ci mal V alue T a ble s in Appendix A, sca n label(s) that represents the desired position to be inserted. 4. Sca n the "Complete" la bel of "Chara cter Posi ...
-
IC Intracom 460835 - page 65
63 B> Symbologies Selection UPC-A UPC-E EAN-13/JAN-13/ISBN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY % 5 1 A + % 5 1 B + % 5 1 Y + % 5 1 Z + % 5 1 E + % 5 1 F + % 5 1 G + % 5 1 J + % 5 1 H+ % 5 1 I + % 5 1 K + % 5 1 L + % 5 1 M + % 5 1 N+ ...
-
IC Intracom 460835 - page 66
64 Code 2 of 6 T ele pen LCD25 RSS-14 RSS Limited RSS Expa nded All Code s None C> Character Position to be Inserted 1. De ci mal V alue (Appendix A) 2. Complete D> Characters to be Inserted 1. ASCII T a ble (Appendix B) 2. Complete % 5 2 0 + % 5 3 0 + % 5 1 4 + % 5 1 S + % 5 1 P+ % 5 1 T + % 5 1 Q + % 5 1 U + % 5 1 V+ % 5 1 W + ...
-
IC Intracom 460835 - page 67
65 6.12 Setup IR Sensor (LG303 only) <Disable> Enable % 0 XH0 % 0 XH1 ...
-
IC Intracom 460835 - page 68
66 Appendix A De ci mal V alue T a ble 8 0 1 2 3 4 5 6 7 9 ...
-
IC Intracom 460835 - page 69
67 Appendix B ASCII T a ble NULL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 0 3 0 0 0 2 0 1 0 4 0 5 0 6 0 7 0 8 0 9 0A 0B 0C 0D 0E 0 F 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1A 1B 1C 1D 1E 1 F ...
-
IC Intracom 460835 - page 70
68 SP ACE ! " # $ % & ' ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2A 2B 2C 2D 2E 2 F 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3A 3B 3C 3D 3E 3 F ...
-
IC Intracom 460835 - page 71
69 @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ] ^ _ 4 0 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4A 4B 4C 4E 4D 4 F 5 0 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 5A 5B 5C 5D 5E 5 F ...
-
IC Intracom 460835 - page 72
70 ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL 6 0 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 9 6A 6B 6C 6D 6E 6 F 7 0 7 1 7 2 7 3 7 4 7 5 7 6 7 7 7 8 7 9 7A 7B 7C 7D 7E 7 F ...
-
IC Intracom 460835 - page 73
71 Appendix C Function Key T a ble F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F1 1 F12 Insert Delete Home Page Up Page Down End Left Right Up Down C 1 C 0 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C 9 C A C B C C C D C E C F D 0 D 1 D 2 D 3 D 4 D 5 ...
-
IC Intracom 460835 - page 74
%$ + / 0 %$ + / 1 %$ + / 2 %$ + / 3 %$ + / 4 %$ + / 6 %$ + / 5 Save Para meters Recall Stored Para meters Set All Defaults Start Configuration End Configuration Abort Configuration V ersion Information Ver 3.8 a 0145-85E00J1 ...
A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals IC Intracom 460835, service manual, brief instructions and user manuals IC Intracom 460835. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product IC Intracom 460835.
Similar manuals
A complete manual for the device IC Intracom 460835, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use IC Intracom 460835 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of IC Intracom 460835.
A complete IC Intracom manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.
1. Preface and tips on how to use the manual IC Intracom 460835 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the IC Intracom 460835, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the IC Intracom 460835, that we can find in the current document
3. Tips how to use the basic functions of the device IC Intracom 460835 - which should help us in our first steps of using IC Intracom 460835
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with IC Intracom 460835
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of IC Intracom 460835 in a specific country, if it was not possible to solve the problem on our own.
Do you have a question concerning IC Intracom 460835?
Use the form below
If you did not solve your problem by using a manual IC Intracom 460835, ask a question using the form below. If a user had a similar problem with IC Intracom 460835 it is likely that he will want to share the way to solve it.