Manual de instrucciones Heat & Glo CFL-18LP-C

28 de páginas 1.38 mb
Descargar

Pasar a la página of 28

Summary
  • Heat & Glo CFL-18LP-C - page 1

    1 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 MODELS: NA TURAL GAS PROP ANE CFL-18NG-C CFL-18LP-C CFL-24NG-C CFL-24LP-C CFL-30NG-C CFL-30LP-C ST -CFL-24NG-B ST -CFL-24LP-B CFL-24NG-IPI CFL-24LP-IPI • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any ...

  • Heat & Glo CFL-18LP-C - page 2

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____________________ Deal ...

  • Heat & Glo CFL-18LP-C - page 3

    3 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08  = Contains updated information. T able of Contents 1 Introduction A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. High Altitude Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Getting Star ...

  • Heat & Glo CFL-18LP-C - page 4

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 4 opening provided by the fi replace chimney damper to vent the fl ue products must not be less than 51 square inches (328 cm 2 ). The chimney damper MUST be fi xed in a man- ner to maintain the minimum permanent vent opening. This may be accomplished by fa ...

  • Heat & Glo CFL-18LP-C - page 5

    5 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 MODEL CFL-18-C MINIMUM FIREPLACE SIZE FRONT WIDTH : 23 1/2 ” (750mm) REAR WIDTH : 19 1/2 ” (521mm) DEPTH : 13 1/2 ” (331mm) HEIGHT : 22” (508mm) 23 1/2 MODEL CFL-24-C TOP VIEW MINIMUM FIREPLACE SIZE FRONT WIDTH : 27 1/2 ” (750mm) REAR WIDTH : 22” ...

  • Heat & Glo CFL-18LP-C - page 6

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 6 Figure 2. DAMPER CLAMP OPEN DAMPER These models contain complete gas-burner , grate(s), and log components needed. Use caution when handling logs to avoid damage. Position the gas-burner assembly to the rear of the fi replace. The ST -CFL-24 log set should ...

  • Heat & Glo CFL-18LP-C - page 7

    7 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Figure 3. IPI Wiring Diagram-CFL-24NG-IPI and CFL-24LP-IPI 7. T est fi re the unit after referring to the SAFETY INFOR- MA TION and LIGHTING INSTRUCTIONS found in Section 3 in this manual, or on the label plate assembly found on the gas-burner . 8. After th ...

  • Heat & Glo CFL-18LP-C - page 8

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 8 • If a remote control is used, the receiver cannot be placed under the burner . If possible, place the receiver outside the combustion chamber . • If the receiver must be placed in the combustion chamber , the protective heat shield MUST be used. See Fig ...

  • Heat & Glo CFL-18LP-C - page 9

    9 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Upon completing the gas line connection, a small amount of air will be in the lines. When fi rst lighting the pilot light, it will take a few minutes for the lines to purge themselves of this air . Once the purging is complete, the pilot and burner will lig ...

  • Heat & Glo CFL-18LP-C - page 10

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 10 Lighting Instructions (IPI) The IPI system must be operated with two D-cell batteries. 1. Turn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burn ...

  • Heat & Glo CFL-18LP-C - page 11

    11 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. Do not force. 5. Close control access pa ...

  • Heat & Glo CFL-18LP-C - page 12

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 12 A. Standing Pilot Ignition System 4 4 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed ...

  • Heat & Glo CFL-18LP-C - page 13

    13 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. (Continued) c. V alve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals. The millivolt meter sh ...

  • Heat & Glo CFL-18LP-C - page 14

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 14 B. Intelli fi re Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. a. Incorrect wiring. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected ...

  • Heat & Glo CFL-18LP-C - page 15

    15 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation ...

  • Heat & Glo CFL-18LP-C - page 16

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 16 Service Parts Diagram CFL-18NG-C, CFL-18LP-C A. Service Parts 5 5 Reference Materials Part number list on following page. Log Set Assembly 5 2 4 9 8 6 1 3 10 7 11 12 13 14 15 16 17 Beginning Manufacturing Date: Nov . 2007 Ending Manufacturing Date: ______ ...

  • Heat & Glo CFL-18LP-C - page 17

    17 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-18NG-C, CFL-18LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an author ...

  • Heat & Glo CFL-18LP-C - page 18

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 18 Service Parts Diagram Service Parts CFL-24NG-IPI, CFL-24LP-IPI Part number list on following page. Log Set Assembly 5 10 6 1 3 4 2 7 9 8 11 12 13 14 16 17 18 15 Beginning Manufacturing Date: June 2008 Ending Manufacturing Date: ______ ...

  • Heat & Glo CFL-18LP-C - page 19

    19 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRI ...

  • Heat & Glo CFL-18LP-C - page 20

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 20 Service Parts Diagram Service Parts CFL-24NG-C, CFL-24LP-C Part number list on following page. Log Set Assembly 5 10 6 1 3 4 2 7 9 8 11 12 13 14 15 16 17 Beginning Manufacturing Date: Nov . 2007 Ending Manufacturing Date: ______ ...

  • Heat & Glo CFL-18LP-C - page 21

    21 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-24NG-C, CFL-24LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an author ...

  • Heat & Glo CFL-18LP-C - page 22

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 22 Service Parts Diagram Service Parts CFL-30NG-C, CFL-30LP-C Part number list on following page. Log Set Assembly 11 12 13 14 15 16 17 10 8 9 5 11 7 1 3 2 4 6 Beginning Manufacturing Date: Nov . 2007 Ending Manufacturing Date: ______ ...

  • Heat & Glo CFL-18LP-C - page 23

    23 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-30NG-C, CFL-30LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an author ...

  • Heat & Glo CFL-18LP-C - page 24

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 24 Service Parts Diagram Service Parts ST -CFL-24NG-B, ST -CFL-24LP-B Part number list on following page. Log Set Assembly 11 12 9 8 1 10 7 2 4 3 5 6 13 14 15 16 17 18 19 20 Beginning Manufacturing Date: Nov . 2007 Ending Manufacturing Date: ______ ...

  • Heat & Glo CFL-18LP-C - page 25

    25 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 ST -CFL-24NG-B, ST -CFL-24LP-B Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from a ...

  • Heat & Glo CFL-18LP-C - page 26

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 26 B. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authoriz ...

  • Heat & Glo CFL-18LP-C - page 27

    27 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic ins ...

  • Heat & Glo CFL-18LP-C - page 28

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 28 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo deale ...

Fabricante Heat & Glo Categoría Indoor Fireplace

Los documentos del dispositivo Heat & Glo CFL-18LP-C que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Heat & Glo
- manuales de instrucciones CFL-18LP-C
- hojas de producto Heat & Glo
- folletos informativos
- o etiquetas energéticas Heat & Glo CFL-18LP-C
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Heat & Glo CFL-18LP-C.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Heat & Glo CFL-18LP-C, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Heat & Glo CFL-18LP-C. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Heat & Glo CFL-18LP-C.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Heat & Glo CFL-18LP-C, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Heat & Glo CFL-18LP-C. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Heat & Glo CFL-18LP-C.

El manual de instrucciones completo de Heat & Glo debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Heat & Glo CFL-18LP-C - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Heat & Glo CFL-18LP-C, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Heat & Glo CFL-18LP-C que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Heat & Glo CFL-18LP-C - que deben facilitarnos los primeros pasos durante el uso de Heat & Glo CFL-18LP-C
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Heat & Glo CFL-18LP-C
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Heat & Glo CFL-18LP-C en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Heat & Glo CFL-18LP-C?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Heat & Glo CFL-18LP-C, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Heat & Glo CFL-18LP-C probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)