Manual Heat & Glo CFL-18LP-C

28 pages 1.38 mb
Download

Go to site of 28

Summary
  • Heat & Glo CFL-18LP-C - page 1

    1 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 MODELS: NA TURAL GAS PROP ANE CFL-18NG-C CFL-18LP-C CFL-24NG-C CFL-24LP-C CFL-30NG-C CFL-30LP-C ST -CFL-24NG-B ST -CFL-24LP-B CFL-24NG-IPI CFL-24LP-IPI • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any ...

  • Heat & Glo CFL-18LP-C - page 2

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____________________ Deal ...

  • Heat & Glo CFL-18LP-C - page 3

    3 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08  = Contains updated information. T able of Contents 1 Introduction A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. High Altitude Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Getting Star ...

  • Heat & Glo CFL-18LP-C - page 4

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 4 opening provided by the fi replace chimney damper to vent the fl ue products must not be less than 51 square inches (328 cm 2 ). The chimney damper MUST be fi xed in a man- ner to maintain the minimum permanent vent opening. This may be accomplished by fa ...

  • Heat & Glo CFL-18LP-C - page 5

    5 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 MODEL CFL-18-C MINIMUM FIREPLACE SIZE FRONT WIDTH : 23 1/2 ” (750mm) REAR WIDTH : 19 1/2 ” (521mm) DEPTH : 13 1/2 ” (331mm) HEIGHT : 22” (508mm) 23 1/2 MODEL CFL-24-C TOP VIEW MINIMUM FIREPLACE SIZE FRONT WIDTH : 27 1/2 ” (750mm) REAR WIDTH : 22” ...

  • Heat & Glo CFL-18LP-C - page 6

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 6 Figure 2. DAMPER CLAMP OPEN DAMPER These models contain complete gas-burner , grate(s), and log components needed. Use caution when handling logs to avoid damage. Position the gas-burner assembly to the rear of the fi replace. The ST -CFL-24 log set should ...

  • Heat & Glo CFL-18LP-C - page 7

    7 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Figure 3. IPI Wiring Diagram-CFL-24NG-IPI and CFL-24LP-IPI 7. T est fi re the unit after referring to the SAFETY INFOR- MA TION and LIGHTING INSTRUCTIONS found in Section 3 in this manual, or on the label plate assembly found on the gas-burner . 8. After th ...

  • Heat & Glo CFL-18LP-C - page 8

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 8 • If a remote control is used, the receiver cannot be placed under the burner . If possible, place the receiver outside the combustion chamber . • If the receiver must be placed in the combustion chamber , the protective heat shield MUST be used. See Fig ...

  • Heat & Glo CFL-18LP-C - page 9

    9 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Upon completing the gas line connection, a small amount of air will be in the lines. When fi rst lighting the pilot light, it will take a few minutes for the lines to purge themselves of this air . Once the purging is complete, the pilot and burner will lig ...

  • Heat & Glo CFL-18LP-C - page 10

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 10 Lighting Instructions (IPI) The IPI system must be operated with two D-cell batteries. 1. Turn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burn ...

  • Heat & Glo CFL-18LP-C - page 11

    11 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. Do not force. 5. Close control access pa ...

  • Heat & Glo CFL-18LP-C - page 12

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 12 A. Standing Pilot Ignition System 4 4 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed ...

  • Heat & Glo CFL-18LP-C - page 13

    13 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. (Continued) c. V alve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals. The millivolt meter sh ...

  • Heat & Glo CFL-18LP-C - page 14

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 14 B. Intelli fi re Ignition System Symptom Possible Cause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. a. Incorrect wiring. V erify “S” wire (white) for sensor and “I” wire (orange) for ignitor are connected ...

  • Heat & Glo CFL-18LP-C - page 15

    15 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation ...

  • Heat & Glo CFL-18LP-C - page 16

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 16 Service Parts Diagram CFL-18NG-C, CFL-18LP-C A. Service Parts 5 5 Reference Materials Part number list on following page. Log Set Assembly 5 2 4 9 8 6 1 3 10 7 11 12 13 14 15 16 17 Beginning Manufacturing Date: Nov . 2007 Ending Manufacturing Date: ______ ...

  • Heat & Glo CFL-18LP-C - page 17

    17 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-18NG-C, CFL-18LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an author ...

  • Heat & Glo CFL-18LP-C - page 18

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 18 Service Parts Diagram Service Parts CFL-24NG-IPI, CFL-24LP-IPI Part number list on following page. Log Set Assembly 5 10 6 1 3 4 2 7 9 8 11 12 13 14 16 17 18 15 Beginning Manufacturing Date: June 2008 Ending Manufacturing Date: ______ ...

  • Heat & Glo CFL-18LP-C - page 19

    19 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRI ...

  • Heat & Glo CFL-18LP-C - page 20

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 20 Service Parts Diagram Service Parts CFL-24NG-C, CFL-24LP-C Part number list on following page. Log Set Assembly 5 10 6 1 3 4 2 7 9 8 11 12 13 14 15 16 17 Beginning Manufacturing Date: Nov . 2007 Ending Manufacturing Date: ______ ...

  • Heat & Glo CFL-18LP-C - page 21

    21 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-24NG-C, CFL-24LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an author ...

  • Heat & Glo CFL-18LP-C - page 22

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 22 Service Parts Diagram Service Parts CFL-30NG-C, CFL-30LP-C Part number list on following page. Log Set Assembly 11 12 13 14 15 16 17 10 8 9 5 11 7 1 3 2 4 6 Beginning Manufacturing Date: Nov . 2007 Ending Manufacturing Date: ______ ...

  • Heat & Glo CFL-18LP-C - page 23

    23 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 CFL-30NG-C, CFL-30LP-C Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an author ...

  • Heat & Glo CFL-18LP-C - page 24

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 24 Service Parts Diagram Service Parts ST -CFL-24NG-B, ST -CFL-24LP-B Part number list on following page. Log Set Assembly 11 12 9 8 1 10 7 2 4 3 5 6 13 14 15 16 17 18 19 20 Beginning Manufacturing Date: Nov . 2007 Ending Manufacturing Date: ______ ...

  • Heat & Glo CFL-18LP-C - page 25

    25 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 ST -CFL-24NG-B, ST -CFL-24LP-B Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from a ...

  • Heat & Glo CFL-18LP-C - page 26

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 26 B. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authoriz ...

  • Heat & Glo CFL-18LP-C - page 27

    27 Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic ins ...

  • Heat & Glo CFL-18LP-C - page 28

    Heat & Glo • CFL-18/24/30-C, CFL-24-IPI, ST -CFL-24-B • 526-910 Rev . E • 10/08 28 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo deale ...

Manufacturer Heat & Glo Category Indoor Fireplace

Documents that we receive from a manufacturer of a Heat & Glo CFL-18LP-C can be divided into several groups. They are, among others:
- Heat & Glo technical drawings
- CFL-18LP-C manuals
- Heat & Glo product data sheets
- information booklets
- or energy labels Heat & Glo CFL-18LP-C
All of them are important, but the most important information from the point of view of use of the device are in the user manual Heat & Glo CFL-18LP-C.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Heat & Glo CFL-18LP-C, service manual, brief instructions and user manuals Heat & Glo CFL-18LP-C. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Heat & Glo CFL-18LP-C.

A complete manual for the device Heat & Glo CFL-18LP-C, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Heat & Glo CFL-18LP-C by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Heat & Glo CFL-18LP-C.

A complete Heat & Glo manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Heat & Glo CFL-18LP-C - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Heat & Glo CFL-18LP-C, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Heat & Glo CFL-18LP-C, that we can find in the current document
3. Tips how to use the basic functions of the device Heat & Glo CFL-18LP-C - which should help us in our first steps of using Heat & Glo CFL-18LP-C
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Heat & Glo CFL-18LP-C
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Heat & Glo CFL-18LP-C in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Heat & Glo CFL-18LP-C?

Use the form below

If you did not solve your problem by using a manual Heat & Glo CFL-18LP-C, ask a question using the form below. If a user had a similar problem with Heat & Glo CFL-18LP-C it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)