    AP13370-2 (08/06) FOR YOUR SAFETY! — Do not store or use gasoline or other flammable vapors or liquids or other combustible materials in the vicinity of this or any other appliance. T o do so may result in an explosion or fir e. — WHA T T O DO IF YOU SMELL GAS ● Do not try to light any appliance. ● Do not touch any electrical switch; do not ...

  • Ruud AP13370-2 - page 2

    Safety Information Safety Precautions . . . . . . . 3–6 LP Gas Models . . . . . . . . . . . 5 Installation Instructions Location . . . . . . . . . . . . . . . . . 7 V enting . . . . . . . . . . . . . . . 9-12 W ater Supply Connections . . 1 3 Gas Supply . . . . . . . . . . . . . . 14 Pipe Insulation . . . . . . . . . . . 16 Heat T raps . . . . . ...

  • Ruud AP13370-2 - page 3

    Be sure to r ead and understand the entire Use and Car e Manual before attempting to install or operate this water heater . It may save you time and money . Pay particular attention to the Safety Instructions. Failure to follow these warnings could r esult in serious bodily injury or death. Should you have problems understanding the instructions in ...

  • Ruud AP13370-2 - page 4

    Time/T emperatur e Relationship in Scalds W ater T emperature T ime T o Produce a Serious Burn 120°F (49°C) More than 5 minutes 125°F (52°C) 1 1 / 2 to 2 minutes 130°F (54°C) About 30 seconds 135°F (57°C) About 10 seconds 140°F (60°C) Less than 5 seconds 145°F (63°C) Less than 3 seconds 150°F (66°C) About 1 1 / 2 seconds 155°F (68°C ...

  • Ruud AP13370-2 - page 5

    5 LP and Natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or r ecognize this odorant. If you are unsur e or unfamiliar with the smell of LP or natural gas, ask the gas supplier . Other conditions, such as “odorant fade”, which causes the odorant to diminish in intensity , can also ...

  • Ruud AP13370-2 - page 6

    6 Have the installer show you the location of the gas shut-off valve and how to shut it of f if necessary . T urn of f the manual shut-off valve if the water heater has been subjected to overheating, fire, flood, physical damage or if the gas supply fails to shut off. ● Read this manual entirely before installing or operating the water heater . ? ...

  • Ruud AP13370-2 - page 7

    Installing the water heater . This water heater must be installed in accordance with these instructions, local codes, utility company requir ements, and/or in the absence of local codes, use the latest edition of the American National S tandard/National Fuel Gas Code. A copy can be purchased fr om either the American Gas Association, 400 N. Capitol ...

  • Ruud AP13370-2 - page 8

    8 Installing the water heater . Combustion and V entilation Air Proper operation of the water heater requir es air for combustion and ventilation. Provisions for combustion and ventilation air must comply with refer enced codes and standards. NOTICE: If the water heater is installed in an unconfined space within a building of conventional frame, ma ...

  • Ruud AP13370-2 - page 9

    9 The water heater must be installed with the factory supplied blower assembly . V enting The water heater must be vented to the outdoors as described in these instructions. DO NOT connect this water heater to an existing vent or chimney – it must be vented separately from all other appliances. Note: This unit can be vented using only the followi ...

  • Ruud AP13370-2 - page 10

    10 Installing the W ater Heater: Blower Assembly Installation Connect blower assembly with Molex connector . Attach Blower Assembly to top pan using the five screws (see diagram to the left). Install rubber coupling (supplied in the box with water heater) on blower housing and secure it. Horizontal V ent T erminal Location The location of the vent ...

  • Ruud AP13370-2 - page 11

    Minimum and Maximum V ent Length CAUTION: Before proceeding, make sure you understand the procedure and cautions covered in the sections “Joining Pipes and Fittings” and “Cementing Joints” . Joining Pipes and Fittings All pipe, fittings, solvent cement, primers and procedures must conform to American National Standard Institute and American ...

  • Ruud AP13370-2 - page 12

    Installing the water heater . 12 Horizontal V ent Installation Once the vent terminal location has been determined, make a hole through the exterior wall to accommodate the 3” or 4” vent pipe. V ent pipe must exit exterior wall only . Insert a small length of 3” or 4” vent pipe through the wall and connect the coupling as shown. Place the ? ...

  • Ruud AP13370-2 - page 13

    A new combination temperature and pr essure r elief valve, complying with the S tandard for Relief V alves and Automatic Gas Shut-Off Devices for Hot W ater Supply Systems, ANSI Z21.22, is supplied and must remain in the opening pr ovided and marked for the purpose on the water heater . No valve of any type should be installed between the relief va ...

  • Ruud AP13370-2 - page 14

    Installing the water heater . W ARNING: Do not attempt to convert this water heater for use with a differ ent type of gas other than the type shown on the rating plate. Such conversion could result in hazardous operating conditions. Leak T esting The water heater and its gas connections must be leak tested at normal operating pressures before it is ...

  • Ruud AP13370-2 - page 15

    W iring If local codes permit, the water heater may be connected to electric service with the power cord provided (DO NOT use an extension cord). A grounding receptacle is required. If local codes do not permit the use of cord connections, a 120 V , 50/60 Hz power supply , with suitable disconnecting means, must be connected to the black and white ...

  • Ruud AP13370-2 - page 16

    16 For increased energy ef ficiency , some water heaters have been supplied with two 24” (61cm) sections of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements. R E L I E F V A L V E COLD HOT T ypical vertical piping arrangement R E L I E F V A L V E COLD HOT T ypical horizontal ...

  • Ruud AP13370-2 - page 17

    17 T ypical Installation Heat Tr ap 6" (15cm) Min. Heat Tr ap 6" (15cm) Min . Flu e Pipe (ABS or PV S) to Outside Ven t T er minal Rubber Coupling Blo wer Assembly Anode (loc ate d undernea t h Blo wer Assembly) Uni on Uni on To C o ld W ater Supply Therma l Expansion Ta n k (If R equired) Shu t-off V alv e Air Gap 6" (15cm) Hot W a ...

  • Ruud AP13370-2 - page 18

    18 Installation Checklist A. W ater Heater Location B. W ater Supply C. Gas Supply D. Relief V alve E. V enting ❑ Close to area of vent termination. ❑ Indoors and protected from freezing temperatures. ❑ Proper clearance from combustible surfaces observed and water heater not installed on carpeted floor . ❑ Sufficient fresh air supply for pr ...

  • Ruud AP13370-2 - page 19

    T ee fitting for vertical hot water supply lines. Hot water supply to house From HOT outlet on water heater Hot water supply to heating unit Supplemental instructions for gas water heaters installed in potable/space heating applications. Local codes or plumbing authority r equirements may vary fr om the instructions or diagrams pr ovided in this ma ...

  • Ruud AP13370-2 - page 20

    20 Lighting the water heater . Before operating this water heater , be sure to r ead and follow the instructions on the label pictured below and all other labels on the water heater , as well as the warnings printed in this manual. Failure to do so can result in unsafe operation of the water heater resulting in pr operty damage, personal injury , o ...

  • Ruud AP13370-2 - page 21

    DANGER: Hotter water increases the Potential for Hot W ater SCALDS . Households with small children, disabled, or elderly persons may requir e a 120°F (49°C) or lower gas contr ol (thermostat) setting to prevent contact with HOT water . ! W ater T emperatur e Setting The temperature of the water in the water heater can be regulated by setting the ...

  • Ruud AP13370-2 - page 22

    22 Operating the water heater . W ater T emperature Setting… Maximum water temperatures occur just after the burner has shut off. T o determine the water temperature, turn on a hot water faucet and place a thermometer in the water stream. The wide arrow mark near CAUTION on the rim of the temperature dial, represents an approximate water temperat ...

  • Ruud AP13370-2 - page 23

    Car e and cleaning of the water heater . Draining the W ater Heater CAUTION: Shut off gas to the water heater at the gas contr ol (thermostat) gas cock or manual shut-off valve befor e draining water . DANGER: Before manually operating the temperature and pr essure relief valve, make certain no one will be exposed to the hot water r eleased by the ...

  • Ruud AP13370-2 - page 24

    24 V enting System Inspection It is recommended that the water heater ’ s internal flue be inspected annually to be certain it is clean by removing the Blower Assembly . When reinstalling the flue baffle make certain it is hung securely by its hanger at the top of the flue way . Reinstall the Blower Assembly as per instructions on page 10. Make s ...

  • Ruud AP13370-2 - page 25

    Problem Possible Causes What T o Do Condensation This usually happens when  This is normal. After the water in the tank warms a new water heater is up, the condensation will disappear . If, however , the filled for the first time. condition persists, examine the piping and fittings for possible leaks. Moisture from the products  This is norma ...

  • Ruud AP13370-2 - page 26

    26 Befor e Y ou Call For Service… Problem Possible Causes What T o Do Not enough or W ater usage may have  W ait for the water heater to recover after an no hot water exceeded the capacity abnormal demand. of the water heater . Low gas pressure.  Check gas supply pressure and manifold pressure. The pilot burner will not light.  Check the ...

  • Ruud AP13370-2 - page 27

    Replacement Parts. For 75 gallon models using natural or LP gas. Instructions For Placing a Parts Order Address parts orders to the distributor or store where the heater was purchased. All parts orders should include: The model and serial number of the water heater from the rating plate. Specify type of gas (natural or LP) as marked on the rating p ...

  • Ruud AP13370-2 - page 28

    IF YOU NEED SER VICE 1. Should you have any questions about your new water heater , or if it requires adjustment, repair , or routine maintenance, it is suggested that you first contact your installer , plumbing contractor or previously agreed upon service agency . In the event the firm has moved, or is unavailable, refer to the telephone directory ...

Fabricante Ruud Categoría Water Heater

Los documentos del dispositivo Ruud AP13370-2 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Ruud
- manuales de instrucciones AP13370-2
- hojas de producto Ruud
- folletos informativos
- o etiquetas energéticas Ruud AP13370-2
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Ruud AP13370-2.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Ruud AP13370-2, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Ruud AP13370-2. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Ruud AP13370-2.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Ruud AP13370-2, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Ruud AP13370-2. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Ruud AP13370-2.

El manual de instrucciones completo de Ruud debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Ruud AP13370-2 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Ruud AP13370-2, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Ruud AP13370-2 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Ruud AP13370-2 - que deben facilitarnos los primeros pasos durante el uso de Ruud AP13370-2
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Ruud AP13370-2
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Ruud AP13370-2 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Ruud AP13370-2?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Ruud AP13370-2, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Ruud AP13370-2 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)