Ruud AP13370-2の取扱説明書

28ページ 1.79 mb
ダウンロード

ページに移動 of 28

Summary
  • Ruud AP13370-2 - page 1

    AP13370-2 (08/06) FOR YOUR SAFETY! — Do not store or use gasoline or other flammable vapors or liquids or other combustible materials in the vicinity of this or any other appliance. T o do so may result in an explosion or fir e. — WHA T T O DO IF YOU SMELL GAS ● Do not try to light any appliance. ● Do not touch any electrical switch; do not ...

  • Ruud AP13370-2 - page 2

    Safety Information Safety Precautions . . . . . . . 3–6 LP Gas Models . . . . . . . . . . . 5 Installation Instructions Location . . . . . . . . . . . . . . . . . 7 V enting . . . . . . . . . . . . . . . 9-12 W ater Supply Connections . . 1 3 Gas Supply . . . . . . . . . . . . . . 14 Pipe Insulation . . . . . . . . . . . 16 Heat T raps . . . . . ...

  • Ruud AP13370-2 - page 3

    Be sure to r ead and understand the entire Use and Car e Manual before attempting to install or operate this water heater . It may save you time and money . Pay particular attention to the Safety Instructions. Failure to follow these warnings could r esult in serious bodily injury or death. Should you have problems understanding the instructions in ...

  • Ruud AP13370-2 - page 4

    Time/T emperatur e Relationship in Scalds W ater T emperature T ime T o Produce a Serious Burn 120°F (49°C) More than 5 minutes 125°F (52°C) 1 1 / 2 to 2 minutes 130°F (54°C) About 30 seconds 135°F (57°C) About 10 seconds 140°F (60°C) Less than 5 seconds 145°F (63°C) Less than 3 seconds 150°F (66°C) About 1 1 / 2 seconds 155°F (68°C ...

  • Ruud AP13370-2 - page 5

    5 LP and Natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or r ecognize this odorant. If you are unsur e or unfamiliar with the smell of LP or natural gas, ask the gas supplier . Other conditions, such as “odorant fade”, which causes the odorant to diminish in intensity , can also ...

  • Ruud AP13370-2 - page 6

    6 Have the installer show you the location of the gas shut-off valve and how to shut it of f if necessary . T urn of f the manual shut-off valve if the water heater has been subjected to overheating, fire, flood, physical damage or if the gas supply fails to shut off. ● Read this manual entirely before installing or operating the water heater . ? ...

  • Ruud AP13370-2 - page 7

    Installing the water heater . This water heater must be installed in accordance with these instructions, local codes, utility company requir ements, and/or in the absence of local codes, use the latest edition of the American National S tandard/National Fuel Gas Code. A copy can be purchased fr om either the American Gas Association, 400 N. Capitol ...

  • Ruud AP13370-2 - page 8

    8 Installing the water heater . Combustion and V entilation Air Proper operation of the water heater requir es air for combustion and ventilation. Provisions for combustion and ventilation air must comply with refer enced codes and standards. NOTICE: If the water heater is installed in an unconfined space within a building of conventional frame, ma ...

  • Ruud AP13370-2 - page 9

    9 The water heater must be installed with the factory supplied blower assembly . V enting The water heater must be vented to the outdoors as described in these instructions. DO NOT connect this water heater to an existing vent or chimney – it must be vented separately from all other appliances. Note: This unit can be vented using only the followi ...

  • Ruud AP13370-2 - page 10

    10 Installing the W ater Heater: Blower Assembly Installation Connect blower assembly with Molex connector . Attach Blower Assembly to top pan using the five screws (see diagram to the left). Install rubber coupling (supplied in the box with water heater) on blower housing and secure it. Horizontal V ent T erminal Location The location of the vent ...

  • Ruud AP13370-2 - page 11

    Minimum and Maximum V ent Length CAUTION: Before proceeding, make sure you understand the procedure and cautions covered in the sections “Joining Pipes and Fittings” and “Cementing Joints” . Joining Pipes and Fittings All pipe, fittings, solvent cement, primers and procedures must conform to American National Standard Institute and American ...

  • Ruud AP13370-2 - page 12

    Installing the water heater . 12 Horizontal V ent Installation Once the vent terminal location has been determined, make a hole through the exterior wall to accommodate the 3” or 4” vent pipe. V ent pipe must exit exterior wall only . Insert a small length of 3” or 4” vent pipe through the wall and connect the coupling as shown. Place the ? ...

  • Ruud AP13370-2 - page 13

    A new combination temperature and pr essure r elief valve, complying with the S tandard for Relief V alves and Automatic Gas Shut-Off Devices for Hot W ater Supply Systems, ANSI Z21.22, is supplied and must remain in the opening pr ovided and marked for the purpose on the water heater . No valve of any type should be installed between the relief va ...

  • Ruud AP13370-2 - page 14

    Installing the water heater . W ARNING: Do not attempt to convert this water heater for use with a differ ent type of gas other than the type shown on the rating plate. Such conversion could result in hazardous operating conditions. Leak T esting The water heater and its gas connections must be leak tested at normal operating pressures before it is ...

  • Ruud AP13370-2 - page 15

    W iring If local codes permit, the water heater may be connected to electric service with the power cord provided (DO NOT use an extension cord). A grounding receptacle is required. If local codes do not permit the use of cord connections, a 120 V , 50/60 Hz power supply , with suitable disconnecting means, must be connected to the black and white ...

  • Ruud AP13370-2 - page 16

    16 For increased energy ef ficiency , some water heaters have been supplied with two 24” (61cm) sections of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements. R E L I E F V A L V E COLD HOT T ypical vertical piping arrangement R E L I E F V A L V E COLD HOT T ypical horizontal ...

  • Ruud AP13370-2 - page 17

    17 T ypical Installation Heat Tr ap 6" (15cm) Min. Heat Tr ap 6" (15cm) Min . Flu e Pipe (ABS or PV S) to Outside Ven t T er minal Rubber Coupling Blo wer Assembly Anode (loc ate d undernea t h Blo wer Assembly) Uni on Uni on To C o ld W ater Supply Therma l Expansion Ta n k (If R equired) Shu t-off V alv e Air Gap 6" (15cm) Hot W a ...

  • Ruud AP13370-2 - page 18

    18 Installation Checklist A. W ater Heater Location B. W ater Supply C. Gas Supply D. Relief V alve E. V enting ❑ Close to area of vent termination. ❑ Indoors and protected from freezing temperatures. ❑ Proper clearance from combustible surfaces observed and water heater not installed on carpeted floor . ❑ Sufficient fresh air supply for pr ...

  • Ruud AP13370-2 - page 19

    T ee fitting for vertical hot water supply lines. Hot water supply to house From HOT outlet on water heater Hot water supply to heating unit Supplemental instructions for gas water heaters installed in potable/space heating applications. Local codes or plumbing authority r equirements may vary fr om the instructions or diagrams pr ovided in this ma ...

  • Ruud AP13370-2 - page 20

    20 Lighting the water heater . Before operating this water heater , be sure to r ead and follow the instructions on the label pictured below and all other labels on the water heater , as well as the warnings printed in this manual. Failure to do so can result in unsafe operation of the water heater resulting in pr operty damage, personal injury , o ...

  • Ruud AP13370-2 - page 21

    DANGER: Hotter water increases the Potential for Hot W ater SCALDS . Households with small children, disabled, or elderly persons may requir e a 120°F (49°C) or lower gas contr ol (thermostat) setting to prevent contact with HOT water . ! W ater T emperatur e Setting The temperature of the water in the water heater can be regulated by setting the ...

  • Ruud AP13370-2 - page 22

    22 Operating the water heater . W ater T emperature Setting… Maximum water temperatures occur just after the burner has shut off. T o determine the water temperature, turn on a hot water faucet and place a thermometer in the water stream. The wide arrow mark near CAUTION on the rim of the temperature dial, represents an approximate water temperat ...

  • Ruud AP13370-2 - page 23

    Car e and cleaning of the water heater . Draining the W ater Heater CAUTION: Shut off gas to the water heater at the gas contr ol (thermostat) gas cock or manual shut-off valve befor e draining water . DANGER: Before manually operating the temperature and pr essure relief valve, make certain no one will be exposed to the hot water r eleased by the ...

  • Ruud AP13370-2 - page 24

    24 V enting System Inspection It is recommended that the water heater ’ s internal flue be inspected annually to be certain it is clean by removing the Blower Assembly . When reinstalling the flue baffle make certain it is hung securely by its hanger at the top of the flue way . Reinstall the Blower Assembly as per instructions on page 10. Make s ...

  • Ruud AP13370-2 - page 25

    Problem Possible Causes What T o Do Condensation This usually happens when  This is normal. After the water in the tank warms a new water heater is up, the condensation will disappear . If, however , the filled for the first time. condition persists, examine the piping and fittings for possible leaks. Moisture from the products  This is norma ...

  • Ruud AP13370-2 - page 26

    26 Befor e Y ou Call For Service… Problem Possible Causes What T o Do Not enough or W ater usage may have  W ait for the water heater to recover after an no hot water exceeded the capacity abnormal demand. of the water heater . Low gas pressure.  Check gas supply pressure and manifold pressure. The pilot burner will not light.  Check the ...

  • Ruud AP13370-2 - page 27

    Replacement Parts. For 75 gallon models using natural or LP gas. Instructions For Placing a Parts Order Address parts orders to the distributor or store where the heater was purchased. All parts orders should include: The model and serial number of the water heater from the rating plate. Specify type of gas (natural or LP) as marked on the rating p ...

  • Ruud AP13370-2 - page 28

    IF YOU NEED SER VICE 1. Should you have any questions about your new water heater , or if it requires adjustment, repair , or routine maintenance, it is suggested that you first contact your installer , plumbing contractor or previously agreed upon service agency . In the event the firm has moved, or is unavailable, refer to the telephone directory ...

メーカー Ruud カテゴリー Water Heater

Ruud AP13370-2のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AP13370-2の取扱説明書
- Ruudの製品カード
- パンフレット
- またはRuud AP13370-2の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Ruud AP13370-2の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Ruud AP13370-2の取り付け説明書、サービスマニュアル、簡易説明書、またはRuud AP13370-2のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Ruud AP13370-2の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Ruud AP13370-2デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがRuud AP13370-2を使用するのを助ける技術的文書のことです。説明書は通常、全てのRuud AP13370-2ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Ruudの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Ruud AP13370-2の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははRuud AP13370-2の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Ruud AP13370-2に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Ruud AP13370-2デバイスの基本機能を使うにあたってのヒント。 Ruud AP13370-2のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Ruud AP13370-2に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるRuud AP13370-2のメーカー/サービスへの連絡先に関する情報。

Ruud AP13370-2についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもRuud AP13370-2の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRuud AP13370-2で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)