    INSTALLATION AND USER’S MANUAL External and internal temperature recorders DataCOLD 500 T/R Carrier Transicold Europe – 10, Bd de l’Oise – 95031 Cergy Pontoise Cédex – France Carrier Transicold North America, 700 Olympic Drive, Ath ens, Ga. 30601 - U.S.A. Carrier Refrigeration Operation 2003 Printed in France 02-03 / 62-61138-20 ...

  • Carrier 500 T/R - page 2

    Page 2 62-61138-20 (0 2/03) INTRODUCTION This manual is a guideline for the installation and use of the DataCOLD 500 T/R temperature recorders. To avoid loss of warranty coverage due to incompetent installation it is most essential to follow the instructions and recommendations of this manual. DataCOLD 500 T/R recorders are developed and produced t ...

  • Carrier 500 T/R - page 3

    Page 3 62-61138-20 (0 2/03) TABLE OF CONTENTS 1 GENERAL D ESCRIPTION .......................................................................................................... ...................... 4 1.1 LCD Di splay................................................................................................................ .................... ...

  • Carrier 500 T/R - page 4

    1 General description The control panel of the DataCOLD 500 T/R consists of three main components: 1- LCD Display 2- Key board 3- Printer 1.1 LCD Display The display has four lines of information, s howing the following content in the operating mode: Page 4 62-61138-20 (0 2/03) Line 1: Alarm active; temperatures, status of the digital inputs  - ...

  • Carrier 500 T/R - page 5

    1.3 Printer The thermal printer is installed in the right side of the recorder. Due to the so called “Plug and Play concept” the printer can be retrofitted, at any time, without disconnec ting the recorder from power. For retrofit, the existing mechanism will be exchanged for a mechanism with printer. To remove the printer or the housing, press ...

  • Carrier 500 T/R - page 6

    Page 6 62-61138-20 (0 2/03) Digital Inputs The digital inputs allow control and regist ration of doors (open/close) or defrost or refrigeration (on/off) or any other digital input information following the configuration of the recorder. By confi guring the parameters the interpretation of the corresponding status can be distinguished. Power supply ...

  • Carrier 500 T/R - page 7

    12 Core cable Tem p erature in p uts Lt. blue Whit e Whit e Yellow CON4 – Tem p erature in p uts Pink Lt. Blue Gre y Yellow Di g ital in p uts Gre y Pink Violet Brown Orange Violet Blue Green Brown CON3 – Di g itals in p uts Orange Blue Green Red Black Optional Mounting kit If no radio slot is available, the recorder should be mount ed with the ...

  • Carrier 500 T/R - page 8

    Page 8 62-61138-20 (0 2/03) DataCOLD T-Version The T-Version has been designed for outside mounting dire ctly on the body. Usually it is fixed under the refrigeration unit on the front side of the body, where it is easily accessible. For fixing proceed as follows: First hold the box in the desired position and mark the mounting holes . Next step is ...

  • Carrier 500 T/R - page 9

    WARNING : DISCONNECT THE RECORDER FROM THE BATTERY IF THE REFRIGERATION UNIT IS NOT USED FOR MORE THAN TEN (10) DAYS. Page 9 62-61138-20 (0 2/03) ...

  • Carrier 500 T/R - page 10

    - Display background lighting (preferable for the R-Version) Usually the display background light switches on after pr essing any key and switching off automatically after 30 seconds. When a permanent background light is required while driving connect pin 3 to a vehicle ignition +signal. WARNING : NEVER CONNECT DIRECT TO THE BATTERY. - Alarm output ...

  • Carrier 500 T/R - page 11

    Page 11 62-61138-20 ( 02/03)  Changing the language 1. Press the green key and select menu 3.4 with ↑ , ↓ . 2. Press again the green key to edit (enter) the menu 3.4. 3. Select the desired language with < …> and validate with the green key. 4. Press the red key to return to the normal display.  Programming the vehicle ID No. and t ...

  • Carrier 500 T/R - page 12

    Page 12 62-61138-20 ( 02/03) 3 User menu's DataCold 500 T/R have four different user menu’s, which are directly accessible via the keyboard: 1. Print menu 2. Alarm menu 3. User settings menu 4. Status menu 3.1 Print menu Press Blue button. The last selected print choice will be displayed. Printing starts after 2 seconds. Repeatedly pressing ...

  • Carrier 500 T/R - page 13

    Page 13 62-61138-20 ( 02/03) ‘Print time period’ is set to “0 hour“ only the ‘Day start time’ is applicable. ...

  • Carrier 500 T/R - page 14

    Page 14 62-61138-20 ( 02/03) 3.1.7 Day start time A print out starts from the actual time and goes backwards until the time set in this parameter, unless the ‘Print time period’ is shorter. If the ‘Day start time’ is set to “00:00” only the ‘Print period time’ is applicable. This allows you to print back to a maximum of 24 hours. 1. ...

  • Carrier 500 T/R - page 15

    3.3 User settings With the user settings several adjustments can be done to offer the user a maximum of user convenience. By pressing the green button the user setting menu will be activated. Toggle with [ ↑ ], [ ↓ ] between the available menu’s (3.1; 3.2; 3.3; …). Between ‘(..)’ the actual setting is disp layed. With [edit] you enter t ...

  • Carrier 500 T/R - page 16

    < > accept <-cncl 3.3.6 Display back light setting Set the intensity of the back light to your convenience. The light switches on when you press any button and switches off after 30 seconds. 3.5 Display back light setting < > accept <-cncl 3.3.7 Keyboard back light setting Set the intensity of the back light to your convenience. T ...

  • Carrier 500 T/R - page 17

    Page 17 62-61138-20 ( 02/03) The display scrolls the compartments which ar e activated in menu 7 (Compartment settings). Remarks: If there is a communication problem with the serial port of the refrigeration unit or if the refrigeration unit is switched off, the message “Unit connection lost” is displayed. If the refrigeration unit is switched ...

  • Carrier 500 T/R - page 18

    Page 18 62-61138-20 ( 02/03) T3 Input >on/off. Menu structure as 5.1 T4 Input >on/off. Menu structure as 5.1 ...

  • Carrier 500 T/R - page 19

    Page 19 62-61138-20 ( 02/03) Menu 6 : Digital inputs settings 4 inputs for status recording, any input can be switched on/off, assigned with a name and a polarity. A number of names are available as a factory setting, to be selected from a list. In the operating mode you can see on the display which i nputs are activated. An empty small box indicat ...

  • Carrier 500 T/R - page 20

    Page 20 62-61138-20 ( 02/03) Menu 8 : Alarm settings 4 Alarm groups– each with a name to assign, upper- and lower temperature limit and a delay time. Each enabled alarm type can be activated by the user for any compartment, although per compartment only one alarm group can be set at the same time. 8.1 Alarm group 1 >on/off 8.1.1 Name >Froze ...

  • Carrier 500 T/R - page 21

    Page 21 62-61138-20 ( 02/03) Menu 10 : General settings General settings for identifying the unit. 10.1 Temperature units >C The units that temperatures will be disp layed. Either degrees C, or degrees F. 10.2 Sample rate >10 minutes The interval time in Minutes (1, 2, 3,..,15, 20, 25, 30,.., 60 minutes) for storing a temperature measurement ...

  • Carrier 500 T/R - page 22

    Page 22 62-61138-20 ( 02/03) 11.2 COM2 RS-232 port setting Refer to Enclosure E: wiring diagrams to connect the CO M2 RS-232 port of the recorder to the micro of the refrigeration unit. • No protocol. • Third party: light protocol to extrac t part of the data from the recorder. • TMS protocol (9,600 Baud): current protocol to extract all data ...

  • Carrier 500 T/R - page 23

    Page 23 62-61138-20 ( 02/03) 5 Accessories and spare parts ITEM PART NUMBER DESIGNATION NS 12-00585-50 Connection Infra-Red cable for PC 1. 12-00585-51 Aluminium guard for sensor NS 12-00585-52 Handheld probe 16’ ( 5 M ) cable & junction box NS 12-00585-53 Magnetic Door Switch (rear door) NS 12-00585-54 Magnetic Door Switch (side door) 2. 12- ...

  • Carrier 500 T/R - page 24

    Page 24 62-61138-20 ( 02/03) ...

  • Carrier 500 T/R - page 25

    Page 25 62-61138-20 ( 02/03) Enclosure A Technical data a) Technical specification: • Operating voltage : 10-36 Volts DC, prot ected against alternator load shedding. • Power consumption: Nominal 0. 6W, max. 25W (while printing) • Temperature : -22°F to +158°F (-30°C / +70°C) be in operation, -40°F to +185°F (-40°C / +85°C) while in s ...

  • Carrier 500 T/R - page 26

    Enclosure B Replace paper roll If a coloured line appears on the last meter of paper , the paper roll needs to be replaced as follow : 1- Push lock lightly upwards and pull the printer module carefully forward. 2- Open the upper part of the front panel. 3- Insert a new paper roll on the spindle. 4- Place the printer module carefully back into the r ...

  • Carrier 500 T/R - page 27

    Page 27 62-61138-20 ( 02/03) Enclosure C Factory settings 5. Temperature inputs Factory setting 5.1. T1 input On 5.1.1. Type Temperature 5.1.2. Name Return Air 5.2. T2 input On 5.2.1. Type Temperature 5.2.2. Name Rear 5.3. T3 input Off 5.4. T4 input Off 6. Digital Inputs 6.1. D1 Input Off, Refrigeration 6.2. D2 Input Off, Back door 6.3. D3 Input Of ...

  • Carrier 500 T/R - page 28

    Enclosure D Failure codes & Set correction factor procedure If the display shows one of the following values: OC (I) the input is activat ed but no sensor is connected. (ii) the sensor has an open circui t (sensor or wire failure.) SC (I) the sensor has a shor t (sensor or cable failure.) Procedure to set a Correction factor The DataCOLD 500 R/ ...

  • Carrier 500 T/R - page 29

    Enclosure E Wiring diagrams CONNECTOR 1 POWER SUPPLY & DIGITAL OUTPUTS 1 = POWER SUPPLY (+) 2 = POWER NEGATIVE (-) 3 = DISPLAY BACKLIGHT (+) 4 = ALARM O/P TEMP 5 = ALARM O/P DIGIT battery Ignition key (+) (display backlight) WARN ING : NEVER CONNECT DISPLA Y BA CKLIGHT DIRECTLY TO THE BATTERY CONNECTOR 3 DIGITAL INPUTS (configuration example) 1 ...

  • Carrier 500 T/R - page 30

    CONNECTOR 2 RS232 a) Serial communication w ith micro of th e refrigeration unit w ithout control panel 1 = GND 2 = RXD 3 = TXD 4 = CTS 5 = RTS Communication cable 3 way P/N : 22-60633-00 Unit microprocessor connector DataCOLD 500 b) Serial communication w ith micro of the refr igeration unit w ith one control panel and “Y” communication cable ...

Fabricante Carrier Categoría Weather Radio

Los documentos del dispositivo Carrier 500 T/R que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Carrier
- manuales de instrucciones 500 T/R
- hojas de producto Carrier
- folletos informativos
- o etiquetas energéticas Carrier 500 T/R
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Carrier 500 T/R.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Carrier 500 T/R, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Carrier 500 T/R. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Carrier 500 T/R.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Carrier 500 T/R, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Carrier 500 T/R. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Carrier 500 T/R.

El manual de instrucciones completo de Carrier debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Carrier 500 T/R - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Carrier 500 T/R, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Carrier 500 T/R que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Carrier 500 T/R - que deben facilitarnos los primeros pasos durante el uso de Carrier 500 T/R
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Carrier 500 T/R
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Carrier 500 T/R en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Carrier 500 T/R?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Carrier 500 T/R, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Carrier 500 T/R probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)