    72 Battery Operated 4-Wire Operation Millivolt Compatible Digital Display DC V oltage Comp atible S tage: 1-Heat, 1-Cool Easy Slide Switch Operation USERS INFORMA TION MANUAL MODEL TST ATBBNQ001 NON-PROGRAMMABLE DIGIT AL THERMOST AT NOTE TO INST ALLER: This manual must be left with the equipment user . Heating & Cooling Systems Heat Cool Thermo ...

  • Bryant TSTATBBNQ001 - page 2

    P age 1 Ta ble Of Content s LOCA TION OF CONTROLS DISPLAY NORMAL OPERA TION PREP ARA TION REMOVE OLD THERMOSTA T WIRE CONNECTIONS JUMPER CONFIGURA TION TEST OPERA TION TROUBLESHOOTING W ARRANTY 2 4 5 6 7 10 17 20 21 INSTA LLA TION AND BA TTER Y REPLACEMENT 8 24 Bryant Heating & Cooling Systems Patents Pending 4/03 ...

  • Bryant TSTATBBNQ001 - page 3

    TST A TBBNQ001 Safety W arnings P age 2 CAUTION Follow Installation Instructions carefully . DISCONNECT POWER T O THE HEA TER - AIR CONDITIONER BEFORE REMOVING THE OLD THERMOST A T AND INST ALLING THE NEW THERMOST A T . W ARNING The 2 Alkaline “AA” batteries must be replaced at least every 12 months to assure proper operation. The thermostat wi ...

  • Bryant TSTATBBNQ001 - page 4

    Location of Controls P age 3 MODE SWITCH Heat, Cool or Off On or Auto FAN SWIT CH UP & DOWN BUTTONS 72 ...

  • Bryant TSTATBBNQ001 - page 5

    Display P age 4 Current room temperature. If the Up or Down arrow buttons are pressed the thermostat will show the desired Set T emp temperature indicator . Once this screen is reached you may use the Up or Down arrow buttons to adjust the desired room temperature. After five seconds with no button presses the thermostat will revert back to show th ...

  • Bryant TSTATBBNQ001 - page 6

    P age 5 Normal Operation Manual Operation Select heat or cool with the mode switch. Normally leave the fan switched to auto. In fan auto, the fan will turn on only with a heat or cool demand. When Fan On is selected, the fan will run continuously , even when the mode switch is set to Off . Adjust the desired set temperature with the Up or Down butt ...

  • Bryant TSTATBBNQ001 - page 7

    Step #1 Prep aration P age 6 These tools will be required: Flat Blade Screwdriver Wire cutter & S tripper Make sure your Heater/Air Conditioner is working properly before beginning installation of the thermost at. Carefully unpack the thermost at. Save the screws and instructions. T urn off the power to the Heating/Air Conditioning system at th ...

  • Bryant TSTATBBNQ001 - page 8

    P age 7 Step #2 Remove & Replace Old Thermost at Remove the cover of the old thermostat. If it does not come off easily check for screws. Loosen the screws holding the thermostat base or subbase to the wall, and lift away . Disconnect the wires from the old thermostat. T ape the ends of the wires as you disconnect them, and mark them with the l ...

  • Bryant TSTATBBNQ001 - page 9

    P age 8 The top of the thermostat housing has two (2) screw- driver slots to assist when seperating. Repeat the procedure in the other screw driver slot. Separate the housing halves by pulling the top forward until the pins release, and then lift the bottom out. SCREWDRIVER SLOTS The batteries must be replaced immediately when the thermostat displa ...

  • Bryant TSTATBBNQ001 - page 10

    P age 9 Battery Replacement REPLACE WITH A LKALINE BA TTERIES A T LEAST ONCE EVER Y YEAR, OR WHEN THE “LOW BA TTER Y” ICON APPEARS (pages 2,8). USE “ AA ” SIZE ALKALINE BA TTERIES USE “ AA ” SIZE ALKALINE BA TTERIES POSITION BA TTERIES A S SHOWN FAN W/ HEA T HEA T PUMP 1 2 3 1 2 3 J1 J2 ...

  • Bryant TSTATBBNQ001 - page 11

    72 Heat Off Cool Fan On FanA uto If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below , or the wiring diagrams that follow . Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked Y1 or Y Cooling Y Power Rh, R, M, V r , A R B B Rev . V al ...

  • Bryant TSTATBBNQ001 - page 12

    Sample Wiring Diagrams FA N COOLING POWER W G R Y W Y B O G R 4 Wire, 1 St age Cooling, 1 Stage Gas Heat Residential Gas or Electric Heat * , Electric Cool, split systems & package units P age 11 GAS OR ELECTRIC HEA T 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. ...

  • Bryant TSTATBBNQ001 - page 13

    P age 12 Sample Wiring Diagrams 4 Wire, 1 St age Cooling, 1 Stage Heat-Heat Pump with O reversing valve*. Residential Heat Pumps, split systems & package units, with no auxiliary heat. FA N POWER G R COMPRESSOR Y W Y B O G R REVERSING V AL VE O * For Heat Pump or Electric Heat applications see page 17 or 18 for Jumper configuration. 4 Conductor ...

  • Bryant TSTATBBNQ001 - page 14

    P age 13 Sample Wiring Diagrams 4 Wire, 1 St age Cooling, 1 Stage Heat-Heat Pump with B reversing valve*. Residential Heat Pumps, split systems & package units, with no auxiliary heat. FA N POWER G R COMPRESSOR Y W Y B O G R REVERSING V AL VE B * For Heat Pump or Electric Heat applications see page 17 or 18 for Jumper configuration. 4 Conductor ...

  • Bryant TSTATBBNQ001 - page 15

    P age 14 Sample Wiring Diagrams FA N POWER G R W W Y B O G R 3 Wire, 1 St age Heat Residential Gas or Electric Heat units with a separately controlled fan. GAS OR ELECTRIC HEA T 3 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. ...

  • Bryant TSTATBBNQ001 - page 16

    P age 15 Sample Wiring Diagrams POWER W R W Y B O G R 2 Wire, 1 St age Gas Heat Residential Gas or Millivolt units. GAS OR ELECTRIC HEA T 2 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. ...

  • Bryant TSTATBBNQ001 - page 17

    P age 16 Sample Wiring Diagrams FA N COOLING POWER G R Y W Y B O G R 3 Wire, 1 St age Cooling Residential Electric Cool units 3 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. ...

  • Bryant TSTATBBNQ001 - page 18

    P age 17 Step #5 Jumper Configuration FAN W/ HEA T HEA T PUMP 1 2 3 1 2 3 J1 J2 Jumper and Jumper are shown in the factory default positions for typical gas furnace heating with electric cooling. *Outputs active - For normal operation do not connect to equipment OUTPUTS No Demand With Demand Cooling Mode Heating Mode O* Y , G , O* B* W Figure-A) 72 ...

  • Bryant TSTATBBNQ001 - page 19

    P age 18 Step #5 Jumper Configuration FAN W/ HEA T HEA T PUMP 1 2 3 1 2 3 J1 J2 Jumper is used to select Fan On (G) with Heat (W). Jumper shown in the factory default position. *Outputs active - For normal operation do not connect to equipment OUTPUTS No Demand With Demand Cooling Mode Heating Mode O* Y , G , O* B* W, G Figure-B) 72 Heat Off Cool F ...

  • Bryant TSTATBBNQ001 - page 20

    P age 19 Step #5 Jumper Configuration FAN W/ HEA T HEA T PUMP 1 2 3 1 2 3 J1 J2 Jumper and Jumper are used to select heat pump operation. Note: Thermost at Does Not Have Auxiliary Heat / Emergency Heat Capability . Leave jumpers in original factory default positions (figure-A) for non heat pump applications. Figure-C) OUTPUTS No Demand With Demand ...

  • Bryant TSTATBBNQ001 - page 21

    P age 20 Step #5 T est Operation Adjust the Slide Switch until it is located under the word HEA T on the thermostat. Press the Up or Down buttons until the set temperature is 10 degrees above room temperature. The HV AC unit should energize in the heating mode (pages 4-5). Adjust the Slide Switch until it is located under the word COOL on the therm ...

  • Bryant TSTATBBNQ001 - page 22

    P age 21 T roubleshooting SYMPTOM: The slide switches on the thermostat are very difficult to move. CAUSE: The backplate of the thermost at is deformed by being screwed tightly into a wall that is not perfectly flat. REMEDY : Loosen the screws holding the thermostat into the wall. 72 Heat Off Cool Fan On FanA uto 72 Heat Off Cool Fan On FanA uto SY ...

  • Bryant TSTATBBNQ001 - page 23

    P age 22 T roubleshooting 4Z95 72 Heat Off Cool Fan On FanA uto C c F FOR HOME OR OFFICE USE T ested to Comply with FCC S tandards Battery S tat TST A TBBNQ001 SYMPTOM: The heating does not attempt to turn on. CAUSE: The heating setpoint is set too low or the Mode Switch is not set for Heat, or the batteries are too weak. REMEDY : Consult the Norma ...

  • Bryant TSTATBBNQ001 - page 24

    THIS WARRANTY DOES NOT INCL UDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping , servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer . THIS WARRANTY APPLIES ONL Y TO PRODUCTS IN THEIR ORIGINAL INSTALLA TION LOCA TION ...

Fabricante Bryant Categoría Thermostat

Los documentos del dispositivo Bryant TSTATBBNQ001 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bryant
- manuales de instrucciones TSTATBBNQ001
- hojas de producto Bryant
- folletos informativos
- o etiquetas energéticas Bryant TSTATBBNQ001
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bryant TSTATBBNQ001.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bryant TSTATBBNQ001, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bryant TSTATBBNQ001. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bryant TSTATBBNQ001.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bryant TSTATBBNQ001, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bryant TSTATBBNQ001. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bryant TSTATBBNQ001.

El manual de instrucciones completo de Bryant debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bryant TSTATBBNQ001 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bryant TSTATBBNQ001, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bryant TSTATBBNQ001 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bryant TSTATBBNQ001 - que deben facilitarnos los primeros pasos durante el uso de Bryant TSTATBBNQ001
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bryant TSTATBBNQ001
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Bryant TSTATBBNQ001 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Bryant TSTATBBNQ001?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bryant TSTATBBNQ001, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bryant TSTATBBNQ001 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)