Manual de instrucciones Zephyr ZVE-E36S

19 de páginas 0.68 mb
Descargar

Pasar a la página of 19

Summary
  • Zephyr ZVE-E36S - page 1

    V enezia Z VE-E3 0S Z VE-E3 6S Z VE-E42S Model number: Serial number: Use, Care, and Installation Guide MAY07.0101 © Zeph yr Corporation. www .zephyronline.com ...

  • Zephyr ZVE-E36S - page 2

    www .zephyronline.com ...

  • Zephyr ZVE-E36S - page 3

    T able of Contents 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting .................................................................. Specific ...

  • Zephyr ZVE-E36S - page 4

    www .zephyronline.com Im p or tan t s afet y N ot i c e 2 T O RE DUC E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T US E T H IS FAN W ITH ANY S O L ID- S T ATE SP E E D C O NTRO L D EV I C E. TO R E DUC E T H E R I S K O F F I R E, E L E C T R I C S H O C K, O R INJ U R Y TO P E R SON S, O B S E RVE T H E F O L LO W I N G: a. Use ...

  • Zephyr ZVE-E36S - page 5

    List of Materials 3 1 - Hood 2 - Metallic lters (3 - ZVE-E3 6, E42) 2 - Halogen light bulbs (4 - ZVE-E3 6, E42) 1 - Duct cover assembly (2 pieces) 1 - Hardware bag 1 - Duct cover mounting bracket 1 - Pac ket of mounting screws w/anchors 1 - Buttery damper NO DUC T I NG IS INCLUDED * Note: Zephyr recommends using 5 0LB E Z anchors if mounting ...

  • Zephyr ZVE-E36S - page 6

    www .zephyronline.com 4 Installation - Ductwork Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3 1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 elbow 15 Ft . x ( ) = Ft. 3 1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 ? ...

  • Zephyr ZVE-E36S - page 7

    5 - n o i t a l l a t s n I e c n a r a e l C & t h g i e H g n i t n u o M DUC T ING min. ducted - 32 1/2” min recirc. - 36” max. 51” *m i n . 9 7 " * * ma x. 123" 36" 9 -27/32" mi n . 2 8" - max . 3 6" Minimum mount height between range top to hood bot- tom should be no less than 28". Maximum mount hei ...

  • Zephyr ZVE-E36S - page 8

    www .zephyronline.com 6 Installation - Ducting W AR NING F IRE HA ZA RD N EVE R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only . Fasten all connections with sheet metal s ...

  • Zephyr ZVE-E36S - page 9

    7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 6.5" 6" 10.37" 13.87" 2.78" 1.87" 0.5" 3/4" Elec. K.O. Cable Lock All Electrical work must by performed by qualied electrician or person with similar technical know how and backgr ound. F or personal safety , remove house fuse or open circuit breaker ...

  • Zephyr ZVE-E36S - page 10

    www .zephyronline.com 8 - n o i t a l l a t s n I r e v o C t c u D & d o o H e h t g n i t n u o M 1. Measure from range top to hood bottom (28” min) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. (10-3/8” from line A) 4. Mark mounting spread from C/ L (9-7 /16”) 5. Fasten E-Z anc hors to wall (see b ...

  • Zephyr ZVE-E36S - page 11

    9 Installation - Ductless Recirculating Ductless recirculating i s intended for applications where an exhaust duct work is not possible to be installed. W hen converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and e xhaust from cooking is drawn and ltered by a set of optional charcoal lters. The a ...

  • Zephyr ZVE-E36S - page 12

    www .zephyronline.com 10 F eatures & Controls - T ouc h Controls & F eatures The standard Metal Filters are required to be cleaned frequently and as recommended in order to maintain blo wer eciency . If improperly maintained, residue from cooking will sift though lters and cause damage to hood blowers and other sensitive components; a ...

  • Zephyr ZVE-E36S - page 13

    11 F eatures & Controls - Charcoal Filters Change Indicator Filter Change Reminder (Charcoal, if tted): W hen your hood is installed as a ' Recirculating' (Ductless) unit, it is tted with a set of Charcoal Filters to purify e xhaust and fumes from cooking, then re-circulate the air within the home.These Charcoal Filters are requ ...

  • Zephyr ZVE-E36S - page 14

    www .zephyronline.com 12 F eatures & Controls - Metal Filters Clean Indicator Filter Clean Reminder (Standard Metal Filters tted): W hether your hood is installed as an Exhaust or Purifying unit, a set of metal lters are tted by the factory . These Metal Filters are intended to lter out residue from cooking. They need not be replace ...

  • Zephyr ZVE-E36S - page 15

    13 Maintenance - Cleaning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratc h and damage surface. F or heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish a ...

  • Zephyr ZVE-E36S - page 16

    www .zephyronline.com 14 Maintenance - Lights Replacing Light Bulbs CA UTI O N: Light bulb becomes extremely hot when turned on. DO NO T touch bulb until switched o and cooled. T ouc hing hot bulbs could cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove by turning bulb counter clockwise. If bulbs are dicult ...

  • Zephyr ZVE-E36S - page 17

    15 T rouble Shooting After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal lter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable loc king connector is not connecting pr ...

  • Zephyr ZVE-E36S - page 18

    List of Parts and A ccessories 16 Light Bulb (J D R-E27) Z0B-0011 Metallic Filters (2 pk) Z0F-M042 Metallic Filters (3 pk) Z0F-M043 T elescopic Back Splash 30” Z0S-0013 T elescopic Back Splash 36” Z0S-0016 T elescopic Back Splash 42” Z0S-0012 W ire Spice Rack 30” Z0R-0013 W ire Spice Rack 36” Z0R-0016 W ire Spice Rack 42” Z0R-0012 T o o ...

  • Zephyr ZVE-E36S - page 19

    www.zephyronline.com Warranty One Y ear Service R epair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects. O n e Y ear Parts W arranty: F or one year from date of original purchase, we will provide free of charge, nonconsumabl ...

Fabricante Zephyr Categoría Ventilation Hood

Los documentos del dispositivo Zephyr ZVE-E36S que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Zephyr
- manuales de instrucciones ZVE-E36S
- hojas de producto Zephyr
- folletos informativos
- o etiquetas energéticas Zephyr ZVE-E36S
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Zephyr ZVE-E36S.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Zephyr ZVE-E36S, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Zephyr ZVE-E36S. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Zephyr ZVE-E36S.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Zephyr ZVE-E36S, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Zephyr ZVE-E36S. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Zephyr ZVE-E36S.

El manual de instrucciones completo de Zephyr debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Zephyr ZVE-E36S - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Zephyr ZVE-E36S, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Zephyr ZVE-E36S que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Zephyr ZVE-E36S - que deben facilitarnos los primeros pasos durante el uso de Zephyr ZVE-E36S
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Zephyr ZVE-E36S
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Zephyr ZVE-E36S en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Zephyr ZVE-E36S?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Zephyr ZVE-E36S, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Zephyr ZVE-E36S probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)