POR T ABLE GASOLINE G E N E RA T O RS O WNER’S OPERA TION AND INST ALLA TION MANU AL R IMPORT ANT : Read and understand this manual before operating or servic- ing generator . Improper use of generator can cause serious injury . Keep this manual for future reference. Ge ne ra to r Mo de ls : MGR2900, MGR4500I, and MGR6000I ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 2
2 1 14716 PORT ABLE GASOLINE GENERA T ORS R CAUTION: indicates a hazard which will or can cause minor personal injury or property damage if you ignore warning. 1. Gasoline presents a hazard of fire or explosion. Gasoline is flammable. Its vapor is explosive. • Keep fuel out of children’ s reach. • Refuel generator in a well-vented area. Do ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 3
3 1 14716 O WNER’S MANU AL 1 2 0 / 2 4 0 V T W IS T L O C K 1 2 0 V T W I S T L O C K 1 2 0 V G F C I 1 2 0 V V O L T A G E H O U R M E T E R A U T O - I D L E R E S E T R E S E T R E S E T R E S E T O F F O N S E L E C T O R 1 2 0 O N L Y 1 2 0 + 2 4 0 R E S E T T E S T E N M 0 0 0 0 0 0 0 5 H O U R S 1 /1 0 E F FUEL 9. On ly a qua li fie d el ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 4
4 1 14716 PORT ABLE GASOLINE GENERA T ORS R VENTILA TION DUST , DIRT , RAIN, AND SNO W HIGH AND L OW TEMPERA TURE OPERA TION Air tem perature affects generato r output . Ou tpu t drop s 1% for eac h 10° tem pera ture ris e ab ove 60 ° F. Ver y lo w tem per atu res ma y ma ke the engi ne har d to st art. Se e engi ne ow ner ’s man ual fo r mo re ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 5
5 1 14716 O WNER’S MANU AL SPECIFICA TIONS MODEL MGR2900 MGR4500I MGR6000I Electrical Rated W attage 2500 4500 6000 Rated Amperage 120 V 20.8 37.5 50 240 V –– 18.8 25 Receptacle 120-V , 20-A Duplex –– Y es Y es 120-V , 15-A GFCI Y es Y es Y es 120-V T wist-Lock –– 30 Amp 30 Amp 120/240-V T wist-Lock –– 20 Amp 30 Amp 120-V V oltage ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 6
6 1 14716 PORT ABLE GASOLINE GENERA T ORS R Figure 4 - GFCI Receptacle 2. I f t h e G F C I r e c e p t a c l e t e s t s o k a y, restore power by pushing the RESET button back in. The test lamp should work at this time . IMPORT ANT : Y ou must press the RESET button firmly and fully . It should lock into place. If the GFCI does not lock into pla ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 7
7 1 14716 O WNER’S MANU AL RECEPT ACLE CIRCUIT BREAKER The circuit breakers protect the receptacles and alternator . Overloading generator will trip circuit breaker . A short circuit in item being powered will also trip breaker . If this occurs, unplug electrical load from recep - tacle. Let circuit breaker cool down. Push circuit breaker button ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 8
8 1 14716 PORT ABLE GASOLINE GENERA T ORS R 1 2 0 / 2 4 0 V T W IS T L O C K 1 2 0 V T W I S T L O C K 1 2 0 V G F C I 1 2 0 V V O L T A G E H O U R M E T E R A U T O - I D L E R E S E T R E S E T R E S E T R E S E T O F F O N S E L E C T O R 1 2 0 O N L Y 1 2 0 + 2 4 0 R E S E T T E S T E N M 0 0 0 0 0 0 0 5 H O U R S 1 /1 0 E F FUEL ST ANDBY INST ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 9
9 1 14716 O WNER’S MANU AL Running Starting Equipment W atts W atts 1/2" Drill 1000 1250 T oaster 1200 1200 Coffee maker 1200 1200 Skillet 1200 1200 14" Chain saw 1200 1500 W ater well pump (1/2 hp) 1000 3000 Hot plate/range (per burner) 1500 1500 10" T able saw 2000 6000 W ater heater (storage-type) 5000 5000 Running Starting Equi ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 10
10 1 14716 PORT ABLE GASOLINE GENERA T ORS R 120/ 240V TWIS TLOC K 120V TWIS TLOC K 120V GFCI 1 20V VO L T AG E HO UR MET ER AU TO -ID LE R ESE T R ESE T RESE T RE S E T OF F ON SELE CT O R 120 ON L Y 120 + 240 R E S E T T E S T E N M 00000005 HOU RS 1/ 1 0 OPERA TION GENERAL INFORMA TION This generator is not large enough to power your entire home ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 11
1 1 1 14716 O WNER’S MANU AL CLOSED OPEN Fig ure 12 - Engi ne Swit ch In ON P osi tion ENGINE SW ON OFF OPERA TION Continued Fuel V alve Lever (ON Position) Choke Lever (Closed Position) Fig ure 10 - Fuel V alve Lever On, Choke Lev er C los ed (Mod el MGR4 500 I Sh own) Note: If oil level is too low , oil alert system will keep engine from st ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 12
12 1 14716 PORT ABLE GASOLINE GENERA T ORS R 120 /24 0V TWI STL OCK 120 V TWI STL OCK 120 V GFC I 120 V V O L T A G E HO U R M ETER A U T O -I D LE R ES ET R E SE T RES ET RE S ET OF F O N SEL ECT O R 120 ON L Y 120 + 240 R E S E T T E S T E N M 00000005 HOU RS 1/ 1 0 OPERA TION Continued AUTO-IDLE OPERA TION IMPOR T ANT : Never start engine with e ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 13
13 1 14716 O WNER’S MANU AL CLOSED OPEN MAINTENANCE AND REP AIRS W AR NIN G: Only a qual ifie d ele ctr ica l serv ice per son shou ld ser vic e and repai r the alter nat or on th is gen era tor . Use on ly fa cto ry app rov ed repl aceme nt p arts. HIGH AL TITUDE OPERA TION This generator will not perform well at high altitudes without proper a ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 14
14 1 14716 PORT ABLE GASOLINE GENERA T ORS R TR OUBLESHOO TING W ARNING: Only a qualified electrical service person should service and repair generator . Use only factory approved replacement parts. POSSIBLE CAUSE 1. Loss of residual magnetism 2 . Winding short circuit or loose connections 3. Defective rotor diode 4. Defective capacitor 1. Engine ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 15
15 1 14716 O WNER’S MANU AL WIRING DIA GRAMS Figure 20 - Wiring Diagram, Model MGR2900 Resistance in Ohms Stator Stator Rotor Rotor Capacitor , Main Auxiliary Primary Secondary MFD Diodes (2) Model Winding * Winding ‡ Winding † Winding † 450 V olt 1000 V olt MGR2900 1.6 5.9 6.9 1.33 16 6 Amp MGR4500I 0.835 1.852 4.91 — 40 8 Amp MGR6000I 0 ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 16
16 1 14716 PORT ABLE GASOLINE GENERA T ORS R WIRING DIA GRAMS Continued Figure 21 - Wiring Diagram, Models MGR4500I and MGR6000I GFCI LIN E W H ITE HOT Duplex Circuit Breake r 20A Circuit Breake r 20A Circuit Breake r 25 A/30 A Circui t Breake r 25 A/30A Hour M eter Full Pw r Selecto r Switc h T2 s 1 s 2 Red Yellow Green/Yellow Green/Yellow Grn/ Yl ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 17
17 1 14716 O WNER’S MANU AL 14 27001005S Engine Flange 1 15 WLE-4 Lock W asher , 1/4" 4 16 ** Stator 1 17 27001002 Bearing 1 18 27001009S Diode 2 19 ** Rotor 1 20 27001006 Fan 1 21 26327006 Bolt, 5/16-24 x 5/8" 4 22 WLE-5 Lock W asher , 5/16" 4 P ARTS A V AILABLE - NOT SHOWN 099866-03 Safety Information Decal 1 099866-04 Safety Inf ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 18
18 1 14716 PORT ABLE GASOLINE GENERA T ORS R P ART NUMBER FOR MODEL KEY NO. MGR4500I MGR6000I DESCRIPTION QTY . 1 14285-01 1 14285-02 Alternator Assembly 1 1 1 15243-01 1 15243-01 T op Cover , Alternator 1 2 M10908-27 M10908-27 Screw , 10-32 x 1/2" 4 3 1 15244-01 1 15244-01 End Cover , Alternator 1 4 1 15247-01 1 15247-01 End Cap, Shaft 1 5 1 ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 19
19 1 14716 O WNER’S MANU AL KEY P ART NO. NUMBER DESCRIPTION QTY . 1 1 14673-01 Roll Cage 1 2 NEC-5C Lock Nut, 5/16-18 5 3 103289-02 Shock Mount 3 4 * Bolt, 5/16-18 x 1/2" 1 5 WLE-5 Lock W asher , 5/16" 1 6 1 15388-01 Grounding Strap 1 ILL USTRA TED P ARTS LIST For Model MGR2900 Roll Cage This list contains replaceable parts used in you ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 20
20 1 14716 PORT ABLE GASOLINE GENERA T ORS R 120/240 V TWISTLO C K 120V TW I STLO CK 120V G FCI 120 V VOL T AGE HOUR ME TER AUT O-I DLE R E SE T R E SE T R E SE T R E SE T OFF ON SELECT OR 120 ONL Y 120 + 240 R E S E T T E S T E N M 0 0 0 0 0 0 0 5 H O U R S 1/ 1 0 E F F U E L U n le a d e d G a s o li n e O n ly SAFET Y INFORM A T IO N 14 9 8 16 1 ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 21
21 1 14716 O WNER’S MANU AL P ART NU MBE R F OR MOD EL KEY NO. MGR4500I MGR6000I DESCRIPTION QTY . 1 25954002 25954002 Gas Cap/Fuel Gage 1 2 1 14720-01 1 14720-01 Gas T ank (with 90° fitting) 1 3 1 14787-01 1 14787-01 Screw , 1/4"-28 x 3/4" 4 4 WP-4C WP-4C W asher , 1/4" 4 5 19508001 19508001 Gas Line Clamp 2 6 25985009 — Fuel ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 22
22 1 14716 PORT ABLE GASOLINE GENERA T ORS R P ART NUMBER FOR MODEL KEY NO. MGR4500I MGR6000I DESCRIPTION QTY . 1 1 14738-01 1 14738-01 Control Panel 1 2 22616009 22616009 Circuit Breaker , 20 Amp * 2 3 099833-01 099833-01 120V , 30A T wist-Lock Receptacle * 1 4 104202-01 104202-01 120V , 20A Duplex Receptacle * 1 5 100445-01 100445-01 120V , 15A D ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 23
23 1 14716 O WNER’S MANU AL P ARTS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customer ’ s needs by providing original replacement parts and accessories. T ool & Equipment 5 Manila Drive Hamden, CT 06514-0322 203-248-7553 1-800-397-7553 Grainger Parts Operations 1657 Shermer Road Northbrook ...
-
Master Lock MGR2900, MGR4500I, MGR6000I - page 24
KEEP THIS WARRANTY WARRANTY INFORMA TION FIVE-YEAR LIMITED WARRANTY GASOLINE PORT ABLE GENERA T ORS DESA Specialty Products™ makes no warranty with respect to the engine and engine components not of its manufac- ture. They are subject to warranties of their manufacturers. Robin warrants the engine. See engine owner’ s manual for engine warranty ...
¿Tienes una pregunta acerca de Master Lock MGR2900, MGR4500I, MGR6000I?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Master Lock MGR2900, MGR4500I, MGR6000I, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Master Lock MGR2900, MGR4500I, MGR6000I probablemente compartirá una forma de solucionarlo.