Master Lock MGR2900, MGR4500I, MGR6000Iの取扱説明書

24ページ 2.57 mb
ダウンロード

ページに移動 of 24

Summary
  • Master Lock MGR2900, MGR4500I, MGR6000I - page 1

    POR T ABLE GASOLINE G E N E RA T O RS O WNER’S OPERA TION AND INST ALLA TION MANU AL R IMPORT ANT : Read and understand this manual before operating or servic- ing generator . Improper use of generator can cause serious injury . Keep this manual for future reference. Ge ne ra to r Mo de ls : MGR2900, MGR4500I, and MGR6000I ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 2

    2 1 14716 PORT ABLE GASOLINE GENERA T ORS R CAUTION: indicates a hazard which will or can cause minor personal injury or property damage if you ignore warning. 1. Gasoline presents a hazard of fire or explosion. Gasoline is flammable. Its vapor is explosive. • Keep fuel out of children’ s reach. • Refuel generator in a well-vented area. Do ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 3

    3 1 14716 O WNER’S MANU AL 1 2 0 / 2 4 0 V T W IS T L O C K 1 2 0 V T W I S T L O C K 1 2 0 V G F C I 1 2 0 V V O L T A G E H O U R M E T E R A U T O - I D L E R E S E T R E S E T R E S E T R E S E T O F F O N S E L E C T O R 1 2 0 O N L Y 1 2 0 + 2 4 0 R E S E T T E S T E N M 0 0 0 0 0 0 0 5 H O U R S 1 /1 0 E F FUEL 9. On ly a qua li fie d el ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 4

    4 1 14716 PORT ABLE GASOLINE GENERA T ORS R VENTILA TION DUST , DIRT , RAIN, AND SNO W HIGH AND L OW TEMPERA TURE OPERA TION Air tem perature affects generato r output . Ou tpu t drop s 1% for eac h 10° tem pera ture ris e ab ove 60 ° F. Ver y lo w tem per atu res ma y ma ke the engi ne har d to st art. Se e engi ne ow ner ’s man ual fo r mo re ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 5

    5 1 14716 O WNER’S MANU AL SPECIFICA TIONS MODEL MGR2900 MGR4500I MGR6000I Electrical Rated W attage 2500 4500 6000 Rated Amperage 120 V 20.8 37.5 50 240 V –– 18.8 25 Receptacle 120-V , 20-A Duplex –– Y es Y es 120-V , 15-A GFCI Y es Y es Y es 120-V T wist-Lock –– 30 Amp 30 Amp 120/240-V T wist-Lock –– 20 Amp 30 Amp 120-V V oltage ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 6

    6 1 14716 PORT ABLE GASOLINE GENERA T ORS R Figure 4 - GFCI Receptacle 2. I f t h e G F C I r e c e p t a c l e t e s t s o k a y, restore power by pushing the RESET button back in. The test lamp should work at this time . IMPORT ANT : Y ou must press the RESET button firmly and fully . It should lock into place. If the GFCI does not lock into pla ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 7

    7 1 14716 O WNER’S MANU AL RECEPT ACLE CIRCUIT BREAKER The circuit breakers protect the receptacles and alternator . Overloading generator will trip circuit breaker . A short circuit in item being powered will also trip breaker . If this occurs, unplug electrical load from recep - tacle. Let circuit breaker cool down. Push circuit breaker button ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 8

    8 1 14716 PORT ABLE GASOLINE GENERA T ORS R 1 2 0 / 2 4 0 V T W IS T L O C K 1 2 0 V T W I S T L O C K 1 2 0 V G F C I 1 2 0 V V O L T A G E H O U R M E T E R A U T O - I D L E R E S E T R E S E T R E S E T R E S E T O F F O N S E L E C T O R 1 2 0 O N L Y 1 2 0 + 2 4 0 R E S E T T E S T E N M 0 0 0 0 0 0 0 5 H O U R S 1 /1 0 E F FUEL ST ANDBY INST ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 9

    9 1 14716 O WNER’S MANU AL Running Starting Equipment W atts W atts 1/2" Drill 1000 1250 T oaster 1200 1200 Coffee maker 1200 1200 Skillet 1200 1200 14" Chain saw 1200 1500 W ater well pump (1/2 hp) 1000 3000 Hot plate/range (per burner) 1500 1500 10" T able saw 2000 6000 W ater heater (storage-type) 5000 5000 Running Starting Equi ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 10

    10 1 14716 PORT ABLE GASOLINE GENERA T ORS R 120/ 240V TWIS TLOC K 120V TWIS TLOC K 120V GFCI 1 20V VO L T AG E HO UR MET ER AU TO -ID LE R ESE T R ESE T RESE T RE S E T OF F ON SELE CT O R 120 ON L Y 120 + 240 R E S E T T E S T E N M 00000005 HOU RS 1/ 1 0 OPERA TION GENERAL INFORMA TION This generator is not large enough to power your entire home ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 11

    1 1 1 14716 O WNER’S MANU AL CLOSED OPEN Fig ure 12 - Engi ne Swit ch In ON P osi tion ENGINE SW  ON OFF OPERA TION Continued Fuel V alve Lever (ON Position) Choke Lever (Closed Position) Fig ure 10 - Fuel V alve Lever On, Choke Lev er C los ed (Mod el MGR4 500 I Sh own) Note: If oil level is too low , oil alert system will keep engine from st ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 12

    12 1 14716 PORT ABLE GASOLINE GENERA T ORS R 120 /24 0V TWI STL OCK 120 V TWI STL OCK 120 V GFC I 120 V V O L T A G E HO U R M ETER A U T O -I D LE R ES ET R E SE T RES ET RE S ET OF F O N SEL ECT O R 120 ON L Y 120 + 240 R E S E T T E S T E N M 00000005 HOU RS 1/ 1 0 OPERA TION Continued AUTO-IDLE OPERA TION IMPOR T ANT : Never start engine with e ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 13

    13 1 14716 O WNER’S MANU AL CLOSED OPEN MAINTENANCE AND REP AIRS W AR NIN G: Only a qual ifie d ele ctr ica l serv ice per son shou ld ser vic e and repai r the alter nat or on th is gen era tor . Use on ly fa cto ry app rov ed repl aceme nt p arts. HIGH AL TITUDE OPERA TION This generator will not perform well at high altitudes without proper a ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 14

    14 1 14716 PORT ABLE GASOLINE GENERA T ORS R TR OUBLESHOO TING W ARNING: Only a qualified electrical service person should service and repair generator . Use only factory approved replacement parts. POSSIBLE CAUSE 1. Loss of residual magnetism 2 . Winding short circuit or loose connections 3. Defective rotor diode 4. Defective capacitor 1. Engine ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 15

    15 1 14716 O WNER’S MANU AL WIRING DIA GRAMS Figure 20 - Wiring Diagram, Model MGR2900 Resistance in Ohms Stator Stator Rotor Rotor Capacitor , Main Auxiliary Primary Secondary MFD Diodes (2) Model Winding * Winding ‡ Winding † Winding † 450 V olt 1000 V olt MGR2900 1.6 5.9 6.9 1.33 16 6 Amp MGR4500I 0.835 1.852 4.91 — 40 8 Amp MGR6000I 0 ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 16

    16 1 14716 PORT ABLE GASOLINE GENERA T ORS R WIRING DIA GRAMS Continued Figure 21 - Wiring Diagram, Models MGR4500I and MGR6000I GFCI LIN E W H ITE HOT Duplex Circuit Breake r 20A Circuit Breake r 20A Circuit Breake r 25 A/30 A Circui t Breake r 25 A/30A Hour M eter Full Pw r Selecto r Switc h T2 s 1 s 2 Red Yellow Green/Yellow Green/Yellow Grn/ Yl ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 17

    17 1 14716 O WNER’S MANU AL 14 27001005S Engine Flange 1 15 WLE-4 Lock W asher , 1/4" 4 16 ** Stator 1 17 27001002 Bearing 1 18 27001009S Diode 2 19 ** Rotor 1 20 27001006 Fan 1 21 26327006 Bolt, 5/16-24 x 5/8" 4 22 WLE-5 Lock W asher , 5/16" 4 P ARTS A V AILABLE - NOT SHOWN 099866-03 Safety Information Decal 1 099866-04 Safety Inf ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 18

    18 1 14716 PORT ABLE GASOLINE GENERA T ORS R P ART NUMBER FOR MODEL KEY NO. MGR4500I MGR6000I DESCRIPTION QTY . 1 14285-01 1 14285-02 Alternator Assembly 1 1 1 15243-01 1 15243-01 T op Cover , Alternator 1 2 M10908-27 M10908-27 Screw , 10-32 x 1/2" 4 3 1 15244-01 1 15244-01 End Cover , Alternator 1 4 1 15247-01 1 15247-01 End Cap, Shaft 1 5 1 ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 19

    19 1 14716 O WNER’S MANU AL KEY P ART NO. NUMBER DESCRIPTION QTY . 1 1 14673-01 Roll Cage 1 2 NEC-5C Lock Nut, 5/16-18 5 3 103289-02 Shock Mount 3 4 * Bolt, 5/16-18 x 1/2" 1 5 WLE-5 Lock W asher , 5/16" 1 6 1 15388-01 Grounding Strap 1 ILL USTRA TED P ARTS LIST For Model MGR2900 Roll Cage This list contains replaceable parts used in you ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 20

    20 1 14716 PORT ABLE GASOLINE GENERA T ORS R 120/240 V TWISTLO C K 120V TW I STLO CK 120V G FCI 120 V VOL T AGE HOUR ME TER AUT O-I DLE R E SE T R E SE T R E SE T R E SE T OFF ON SELECT OR 120 ONL Y 120 + 240 R E S E T T E S T E N M 0 0 0 0 0 0 0 5 H O U R S 1/ 1 0 E F F U E L U n le a d e d G a s o li n e O n ly SAFET Y INFORM A T IO N 14 9 8 16 1 ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 21

    21 1 14716 O WNER’S MANU AL P ART NU MBE R F OR MOD EL KEY NO. MGR4500I MGR6000I DESCRIPTION QTY . 1 25954002 25954002 Gas Cap/Fuel Gage 1 2 1 14720-01 1 14720-01 Gas T ank (with 90° fitting) 1 3 1 14787-01 1 14787-01 Screw , 1/4"-28 x 3/4" 4 4 WP-4C WP-4C W asher , 1/4" 4 5 19508001 19508001 Gas Line Clamp 2 6 25985009 — Fuel ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 22

    22 1 14716 PORT ABLE GASOLINE GENERA T ORS R P ART NUMBER FOR MODEL KEY NO. MGR4500I MGR6000I DESCRIPTION QTY . 1 1 14738-01 1 14738-01 Control Panel 1 2 22616009 22616009 Circuit Breaker , 20 Amp * 2 3 099833-01 099833-01 120V , 30A T wist-Lock Receptacle * 1 4 104202-01 104202-01 120V , 20A Duplex Receptacle * 1 5 100445-01 100445-01 120V , 15A D ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 23

    23 1 14716 O WNER’S MANU AL P ARTS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customer ’ s needs by providing original replacement parts and accessories. T ool & Equipment 5 Manila Drive Hamden, CT 06514-0322 203-248-7553 1-800-397-7553 Grainger Parts Operations 1657 Shermer Road Northbrook ...

  • Master Lock MGR2900, MGR4500I, MGR6000I - page 24

    KEEP THIS WARRANTY WARRANTY INFORMA TION FIVE-YEAR LIMITED WARRANTY GASOLINE PORT ABLE GENERA T ORS DESA Specialty Products™ makes no warranty with respect to the engine and engine components not of its manufac- ture. They are subject to warranties of their manufacturers. Robin warrants the engine. See engine owner’ s manual for engine warranty ...

メーカー Master Lock カテゴリー Portable Generator

Master Lock MGR2900, MGR4500I, MGR6000Iのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MGR2900, MGR4500I, MGR6000Iの取扱説明書
- Master Lockの製品カード
- パンフレット
- またはMaster Lock MGR2900, MGR4500I, MGR6000Iの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Master Lock MGR2900, MGR4500I, MGR6000Iの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Master Lock MGR2900, MGR4500I, MGR6000Iの取り付け説明書、サービスマニュアル、簡易説明書、またはMaster Lock MGR2900, MGR4500I, MGR6000Iのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Master Lock MGR2900, MGR4500I, MGR6000Iの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Master Lock MGR2900, MGR4500I, MGR6000Iデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMaster Lock MGR2900, MGR4500I, MGR6000Iを使用するのを助ける技術的文書のことです。説明書は通常、全てのMaster Lock MGR2900, MGR4500I, MGR6000Iユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Master Lockの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Master Lock MGR2900, MGR4500I, MGR6000Iの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMaster Lock MGR2900, MGR4500I, MGR6000Iの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Master Lock MGR2900, MGR4500I, MGR6000Iに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Master Lock MGR2900, MGR4500I, MGR6000Iデバイスの基本機能を使うにあたってのヒント。 Master Lock MGR2900, MGR4500I, MGR6000Iのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Master Lock MGR2900, MGR4500I, MGR6000Iに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMaster Lock MGR2900, MGR4500I, MGR6000Iのメーカー/サービスへの連絡先に関する情報。

Master Lock MGR2900, MGR4500I, MGR6000Iについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMaster Lock MGR2900, MGR4500I, MGR6000Iの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMaster Lock MGR2900, MGR4500I, MGR6000Iで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください