Manual de instrucciones Agilent Technologies 60501B

11 de páginas 0.1 mb
Descargar

Pasar a la página of 11

Summary
  • Agilent Technologies 60501B - page 1

    OPERATING MANUAL 150 WATT ELECTRONIC LOAD MODULE Agilent Model 60501B FOR MO DULES WITH SERIAL NUMBERS: 3118A -00101 A ND A BOVE A gilent Part No. 60501-90009 Printed in U.S.A . Microf iche No. 60501-90010 June, 1991 ...

  • Agilent Technologies 60501B - page 2

    DECLA RA TION OF CONFORMI TY according to IS O/IEC G uide 22 and E N 45014 Manufacturer’s Name : Agilent Tec hnologies Manuf acturer’s A ddress: New Jersey Divi sion 140 Green Pond Road Rock away , NJ 07866 U.S.A. declares that the pr oduct Product Name: Load mainf ram e and m odules Model Number(s): Agilent 6050A, 6051A mainf ram es with m odu ...

  • Agilent Technologies 60501B - page 3

    1 150-Watt Module About This Manual This m anual provides in form ation for t he Ag ilent 60501B 150- Watt Electron ic Load Modul e. It is desig ned as a supplem ent to the A gilent 6050A /6051A Mu ltiple Input Mainf rame Electron ic Load Operating Man ual (part nu mber 06050- 90001). Four tabl es provide th e follow ing modu le-specif ic inf ormat ...

  • Agilent Technologies 60501B - page 4

    2 Table 60501-1. Specification and Supplemental Characteristics SPECIFICA TIO NS DC Input Rating: Current: 0 to 30 A Voltage : 3 to 60 V (min imu m dc operat ion from 0 to 2 V for 0 t o 30 A) Pow er: 150 W at 40 ° C (derated to 112 W at 55 ° C) A . OPERA TING CHARA CTERISTICS B. DERA TED CURRENT DETAIL Constant Current Mode: Ranges: 0 to 3 A; and ...

  • Agilent Technologies 60501B - page 5

    3 Table 60501-1 Specifications and Supplemental Characteristics (continued) Transient Operat ion: Continuous Mode Frequency Range: 0.25 Hz to 10 kHz Frequency Resolution: 4% Frequency A ccuracy : 3% Duty Cy cle Range: 3% to 97% (0.25 Hz to 1 k Hz); 6% to 94% (1 k Hz to 10 kHz) Duty Cy cle Resolution: 4% Duty Cycle A ccuracy : 6% of set ting ± 2% P ...

  • Agilent Technologies 60501B - page 6

    4 Table 60501-1 Specifications and Supplemental Characteristics (continued) External A nalog Programming 0 to 10 V (dc or ac): Bandwidth: 10 kHz (3 db freque ncy ) A ccuracy: ± 4.5% ± 40 m A (0 t o 3 A rang e) ± 4.5% ± 130 m A (0 to 30 A range) ± 0.8% ± 200 mV (0 to 60 V range) Temperature Coeffic ient: 100 ppm/ ° C ± 3 mA/ ° C (cu rrent r ...

  • Agilent Technologies 60501B - page 7

    5 Table 60501-1 Specifications and Supplemental Characteristics (continued) Current Slew Rate:* Rate # 30 A Range Step 3 A Range Step Transition T ime 1 0.5 A/m s 0.05 A/s 8.0 ms 2 1.2 A/m s 0.12 A/s 3.2 ms 3 2.5 A/m s 0.25 A/m s 1.6 ms 4 5 A/m s 0.5 A/m s 800 µ s 5 12 A/m s 1.2 A/m s 320 µ s 6 25 A/m s 2.5 A/m s 160 µ s 7 0.05 A/ µ s 5 A /m s ...

  • Agilent Technologies 60501B - page 8

    6 Table 60501-1 Specifications and Supplemental Characteristics (continued) Source Turn-On Current Overshoot: Less than 10% of fin al value (in CC and CR m odes w hen connected to pow er supplies with voltage rise times of greater than 500 µ s). Programmable Shor t Circuit: 0.066 Ω (0.04 Ω typical) Programmable Open Circuit: 20 k Ω (ty pical ...

  • Agilent Technologies 60501B - page 9

    7 Table 60501-2. Programming Ranges (continued) Transient O peration Set Frequency FREQ value " T RAN:FREQ value" 0.25 Hz to 10 kHz Set Duty Cy cle (shif t) DCYCLE v alue "TRAN: DCYC va lue" 3-97% (0.25 Hz- 1 kHz) 6-94% (1 k Hz-10 kH z) *S et Puls e Width "TRAN:TWID valu e" 0.00005 to 4 s Trigger Operat ion *S et Trigg ...

  • Agilent Technologies 60501B - page 10

    8 Table 60501-4. Calibration Info rmation Ranges and Calibration Points Variables Variables Value Power Supply Settings Current Shunt High C urrent R ange Hi_cu rr_rng 30 5 V/31 A 100 A High C urrent Of fset Hi_curr_off set 0.013 Low Cu rrent Ran ge Lo_curr_rn g 3 5 V/10 A 15 A Low Curren t Off set L o_curr_off set 0.013 Voltage Range N/A N/A 61 V/ ...

  • Agilent Technologies 60501B - page 11

    9 Agilent Sales and Support Office For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir You can also contact one of the following centers and ask for a test and measurement sales representative. United Stat ...

Fabricante Agilent Technologies Categoría Drums

Los documentos del dispositivo Agilent Technologies 60501B que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Agilent Technologies
- manuales de instrucciones 60501B
- hojas de producto Agilent Technologies
- folletos informativos
- o etiquetas energéticas Agilent Technologies 60501B
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Agilent Technologies 60501B.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Agilent Technologies 60501B, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Agilent Technologies 60501B. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Agilent Technologies 60501B.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Agilent Technologies 60501B, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Agilent Technologies 60501B. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Agilent Technologies 60501B.

El manual de instrucciones completo de Agilent Technologies debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Agilent Technologies 60501B - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Agilent Technologies 60501B, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Agilent Technologies 60501B que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Agilent Technologies 60501B - que deben facilitarnos los primeros pasos durante el uso de Agilent Technologies 60501B
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Agilent Technologies 60501B
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Agilent Technologies 60501B en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Agilent Technologies 60501B?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Agilent Technologies 60501B, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Agilent Technologies 60501B probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)