Manual de instrucciones Lennox Hearth MONTEST

24 de páginas 1.4 mb
Descargar

Pasar a la página of 24

Summary
  • Lennox Hearth MONTEST - page 1

    EP A Wood-Burning Fireplace P/N 850,038M REV . A 05/2006 MONTEST MODEL MONTECITO EST A TE™ This installation manual will enable you to obtain a safe, effi cient and de- pendable installation of your fi replace system. Please read and understand these instructions before beginning your installation. Do not alter or modify the fi replace or its ...

  • Lennox Hearth MONTEST - page 2

    W ARNING T o avoid the risk of damaging fi replace materials and increas- ing the risk of fi re, do not use the fi replace to cook or warm food. W ARNING NEVER use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fl uid, naphtha, engine oil or similar liquids to start or “freshen up” a fi re in this fi replace. Keep any ? ...

  • Lennox Hearth MONTEST - page 3

    T ABLE OF CONTENTS Safety Rules ...................................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment ........................... Page 3 Operating The Montecito Estate ......... Page 3 Fuel .................................................. ...

  • Lennox Hearth MONTEST - page 4

    The combustion air control should be opened before opening the doors to minimize the possi- bility of back draft coming into the room ( Figure 1-A ) More details are available in Refueling For Best Performance on Page 5 . Time Delayed Air Boost System The time delayed air -boost system register is located underneath the door handles. Placed in the ...

  • Lennox Hearth MONTEST - page 5

    The unit will burn best with 2-3 pieces of cord wood spaced 1 to 2 inches apart and allowing air to get under the fuel. Criss-crossing or ar - ranging the fuel so that air can get underneath will help the fi re to get started easily . The unit should be operated with the air control fully open long enough to get the cord wood well ignited. REFUELI ...

  • Lennox Hearth MONTEST - page 6

    Figure 5 IMPORT ANT CAUTIONS A. Do not block the hot air vents to the fi re- place as this will cause the fi replace to overheat. B. Never use gasoline, kerosene, charcoal lighter fl uid or similar liquids to start or rekindle a fi re in this fi replace. Keep all such liquids well away from the fi replace at all times. C. Do not burn coal. Th ...

  • Lennox Hearth MONTEST - page 7

    DOOR INST ALLA TION The doors must be put in place only when the installation of the Montecito Estate™ is completed. All you have to do is fi t the male part of the hinge, already on the door , to the female part, which is on the fi replace. T o remove the doors, simply pull them up from the hinges. The door adjustment has been set at the facto ...

  • Lennox Hearth MONTEST - page 8

    FIREPLACE INST ALLA TION Locating The Montecito Estate™ The best location to install your fi replace is determined by considering the location of windows, doors, and the traffi c fl ow in the room where the fi replace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the loc ...

  • Lennox Hearth MONTEST - page 9

    Figure 11 Insulated Chase Construction 7 Ft. Min. Attic Radiation Shield Roof Support Storm Collar Flashing Drywall or Any Rigid Material 2” x 4” 1/2” Plywood 6’ 8” Min. Firestop * Floor Ceiling Wall * Floor Ceiling Wall Fireplace Optional Insulation In Outside Walls Of Chase Solid Continuous Surface Outside Base Insulation (Thermal Barri ...

  • Lennox Hearth MONTEST - page 10

    1. Combustible material must be installed fl ush with the fi replace. It may not project in front of and on the fi replace (i.e. the steel facade of the fi replace) ( Figure 14 ) . 2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fi replace facing ( Figure 13 ) . MANTEL & F ACING The ma ...

  • Lennox Hearth MONTEST - page 11

    Figure 17 13” x 13” 10’ Max. 10’ Max. Rain Cap Flashing Collar Flashing Roof Support Attic Radiation Shield Non-Combustible Flameproof Facing 56” Min. 68” Min. Figure 18 The duct system must be installed respecting the following: 1. Remove the plates closing up the 8” dia. holes on top of the fi replace. Then, cut the insulation in o ...

  • Lennox Hearth MONTEST - page 12

    OUTSIDE AIR KIT It is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and are included with the fi replace: - Outside air kit (includes 40 inch fl ex that goes up to ten (10) feet long) - 4” Adaptor for fi replace connection Outside Air Installation The outside air assembly may b ...

  • Lennox Hearth MONTEST - page 13

    8. A rain cap must be installed on top of the chimney . Failure to install a rain cap may cause corrosion problems. 9. Cut and frame square holes in all fl oors, ceilings, and roof that the chimney will go through to provide a 2” (50 mm) clearance between the chimney and any combustible materials. Do not fi ll this 2” space with insulation or ...

  • Lennox Hearth MONTEST - page 14

    CHIMNEY INST ALLA TION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, fl oor and roof where the chimney will pass (see Figure 22 ). Use a plumb bob to line up the center of the holes. The sizes are indicated in T able 2 for the fl oor and ceiling holes and T able 3 ( Page 15 ) for the roof holes. From below , install a fi restop in ea ...

  • Lennox Hearth MONTEST - page 15

    Roof Down Slope Hole Size DEGREE OF SLOPE Secure T emp™ S2100+ Nova T emp™ HT6000+ Secure T emp GX ACBI Roof Pitch 7” 7” 0 * 15” (380 mm) 15” (380 mm) 2/12 15-3/8” (390 mm) 15-3/8” (390 mm) 4/12 16-1/8” (410 mm) 16-1/8” (410 mm) 6/12 16-7/8” (430 mm) 16-7/8” (430 mm) 8/12 18-1/4” (465 mm) 18-1/4” (465 mm) 10/12 19-5/8” ...

  • Lennox Hearth MONTEST - page 16

    Chimney Elbow Offset & Height T wo Lengths Between Elbows 8 ” 1 2” 1 8” 2 4” 36 ” 8 ” & 36 ” 12” & 36” 18” & 36” 24” & 36” 36” & 36” GX S2100+ HT6000+ 7” 15º A 3” (76 mm) 4-1/4” (108 mm) 5-3/4” (146 mm) 7-1/4” (184 mm) 10-1/4” (260 mm) 12-1/4” (311 mm) 13-1/4” (337 mm) 14-3/4” ...

  • Lennox Hearth MONTEST - page 17

    Figure 28 OFFSET CHIMNEY INST ALLA TION Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 29 Roof Support Note: In cold areas it is recommended to protect the chimney in a insulated chase. Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET CHIMNEY INST ALLA TION WITH WALL PENETR ...

  • Lennox Hearth MONTEST - page 18

    ANGLED WALL RADIA TION SHIELD (XRSMI30 and AC10RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled fi restop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only (XRSMI45). In cold climate locations (climates where temperatures will fall below 32º F / 0º C), ...

  • Lennox Hearth MONTEST - page 19

    INST ALLA TION INSTRUCTIONS FOR MASONRY APPLICA TION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualifi ed chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit corr ...

  • Lennox Hearth MONTEST - page 20

    CHIMNEY - P ARTS AND COMPONENTS LISTS Secure T emp GX - 2” Insulated Galvanized Chimney System (Recommended Insulated System) Galvanized (7” ID & 11” OD) U.S.A. ONL Y Description Cat./Part No. Lengths & Misc. Chimney Components Length 8”, 7GXL8 7GXL8 Length 12”, 7GXL12 7GXL12 Length 18”, 7GXL18 7GXL18 Length 24”, 7GXL24 7GXL24 ...

  • Lennox Hearth MONTEST - page 21

    ACBI Chimney* (7” I.D., 13” O.D. AC - Air Cooled) * AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates (climates where temperatures will fall below 32° F / 0° C). Description Cat./Part No. One of the following adaptors is required if installing an AC chimney system Starter Section w/ air intake, 7” Dia., ACBI7S ...

  • Lennox Hearth MONTEST - page 22

    CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: • Side wall (fi replace front): 24” (457 mm) measured from the fi replace side. • Ceiling: 6’ 8” (2,032 mm) measured from the base of the fi replace • Fireplace enclosure: Bottom: 0” Side: 0” Back: 0” • T op: Do not fi l ...

  • Lennox Hearth MONTEST - page 23

    NOTES 23 ...

  • Lennox Hearth MONTEST - page 24

    Printed in Canada © 2006 by LENNOX HEARTH PRODUCTS P/N 850,038M REV . A 05/2006 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information. LHP 1110 West T aft Ave ...

Fabricante Lennox Hearth Categoría Indoor Fireplace

Los documentos del dispositivo Lennox Hearth MONTEST que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Lennox Hearth
- manuales de instrucciones MONTEST
- hojas de producto Lennox Hearth
- folletos informativos
- o etiquetas energéticas Lennox Hearth MONTEST
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Lennox Hearth MONTEST.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Lennox Hearth MONTEST, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Lennox Hearth MONTEST. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Lennox Hearth MONTEST.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Lennox Hearth MONTEST, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Lennox Hearth MONTEST. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Lennox Hearth MONTEST.

El manual de instrucciones completo de Lennox Hearth debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Lennox Hearth MONTEST - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Lennox Hearth MONTEST, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Lennox Hearth MONTEST que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Lennox Hearth MONTEST - que deben facilitarnos los primeros pasos durante el uso de Lennox Hearth MONTEST
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Lennox Hearth MONTEST
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Lennox Hearth MONTEST en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Lennox Hearth MONTEST?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Lennox Hearth MONTEST, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Lennox Hearth MONTEST probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)