    EP A Wood-Burning Fireplace P/N 850,038M REV . A 05/2006 MONTEST MODEL MONTECITO EST A TE™ This installation manual will enable you to obtain a safe, effi cient and de- pendable installation of your fi replace system. Please read and understand these instructions before beginning your installation. Do not alter or modify the fi replace or its ...

  • Lennox Hearth MONTEST - page 2

    W ARNING T o avoid the risk of damaging fi replace materials and increas- ing the risk of fi re, do not use the fi replace to cook or warm food. W ARNING NEVER use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fl uid, naphtha, engine oil or similar liquids to start or “freshen up” a fi re in this fi replace. Keep any ? ...

  • Lennox Hearth MONTEST - page 3

    T ABLE OF CONTENTS Safety Rules ...................................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment ........................... Page 3 Operating The Montecito Estate ......... Page 3 Fuel .................................................. ...

  • Lennox Hearth MONTEST - page 4

    The combustion air control should be opened before opening the doors to minimize the possi- bility of back draft coming into the room ( Figure 1-A ) More details are available in Refueling For Best Performance on Page 5 . Time Delayed Air Boost System The time delayed air -boost system register is located underneath the door handles. Placed in the ...

  • Lennox Hearth MONTEST - page 5

    The unit will burn best with 2-3 pieces of cord wood spaced 1 to 2 inches apart and allowing air to get under the fuel. Criss-crossing or ar - ranging the fuel so that air can get underneath will help the fi re to get started easily . The unit should be operated with the air control fully open long enough to get the cord wood well ignited. REFUELI ...

  • Lennox Hearth MONTEST - page 6

    Figure 5 IMPORT ANT CAUTIONS A. Do not block the hot air vents to the fi re- place as this will cause the fi replace to overheat. B. Never use gasoline, kerosene, charcoal lighter fl uid or similar liquids to start or rekindle a fi re in this fi replace. Keep all such liquids well away from the fi replace at all times. C. Do not burn coal. Th ...

  • Lennox Hearth MONTEST - page 7

    DOOR INST ALLA TION The doors must be put in place only when the installation of the Montecito Estate™ is completed. All you have to do is fi t the male part of the hinge, already on the door , to the female part, which is on the fi replace. T o remove the doors, simply pull them up from the hinges. The door adjustment has been set at the facto ...

  • Lennox Hearth MONTEST - page 8

    FIREPLACE INST ALLA TION Locating The Montecito Estate™ The best location to install your fi replace is determined by considering the location of windows, doors, and the traffi c fl ow in the room where the fi replace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the loc ...

  • Lennox Hearth MONTEST - page 9

    Figure 11 Insulated Chase Construction 7 Ft. Min. Attic Radiation Shield Roof Support Storm Collar Flashing Drywall or Any Rigid Material 2” x 4” 1/2” Plywood 6’ 8” Min. Firestop * Floor Ceiling Wall * Floor Ceiling Wall Fireplace Optional Insulation In Outside Walls Of Chase Solid Continuous Surface Outside Base Insulation (Thermal Barri ...

  • Lennox Hearth MONTEST - page 10

    1. Combustible material must be installed fl ush with the fi replace. It may not project in front of and on the fi replace (i.e. the steel facade of the fi replace) ( Figure 14 ) . 2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fi replace facing ( Figure 13 ) . MANTEL & F ACING The ma ...

  • Lennox Hearth MONTEST - page 11

    Figure 17 13” x 13” 10’ Max. 10’ Max. Rain Cap Flashing Collar Flashing Roof Support Attic Radiation Shield Non-Combustible Flameproof Facing 56” Min. 68” Min. Figure 18 The duct system must be installed respecting the following: 1. Remove the plates closing up the 8” dia. holes on top of the fi replace. Then, cut the insulation in o ...

  • Lennox Hearth MONTEST - page 12

    OUTSIDE AIR KIT It is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and are included with the fi replace: - Outside air kit (includes 40 inch fl ex that goes up to ten (10) feet long) - 4” Adaptor for fi replace connection Outside Air Installation The outside air assembly may b ...

  • Lennox Hearth MONTEST - page 13

    8. A rain cap must be installed on top of the chimney . Failure to install a rain cap may cause corrosion problems. 9. Cut and frame square holes in all fl oors, ceilings, and roof that the chimney will go through to provide a 2” (50 mm) clearance between the chimney and any combustible materials. Do not fi ll this 2” space with insulation or ...

  • Lennox Hearth MONTEST - page 14

    CHIMNEY INST ALLA TION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, fl oor and roof where the chimney will pass (see Figure 22 ). Use a plumb bob to line up the center of the holes. The sizes are indicated in T able 2 for the fl oor and ceiling holes and T able 3 ( Page 15 ) for the roof holes. From below , install a fi restop in ea ...

  • Lennox Hearth MONTEST - page 15

    Roof Down Slope Hole Size DEGREE OF SLOPE Secure T emp™ S2100+ Nova T emp™ HT6000+ Secure T emp GX ACBI Roof Pitch 7” 7” 0 * 15” (380 mm) 15” (380 mm) 2/12 15-3/8” (390 mm) 15-3/8” (390 mm) 4/12 16-1/8” (410 mm) 16-1/8” (410 mm) 6/12 16-7/8” (430 mm) 16-7/8” (430 mm) 8/12 18-1/4” (465 mm) 18-1/4” (465 mm) 10/12 19-5/8” ...

  • Lennox Hearth MONTEST - page 16

    Chimney Elbow Offset & Height T wo Lengths Between Elbows 8 ” 1 2” 1 8” 2 4” 36 ” 8 ” & 36 ” 12” & 36” 18” & 36” 24” & 36” 36” & 36” GX S2100+ HT6000+ 7” 15º A 3” (76 mm) 4-1/4” (108 mm) 5-3/4” (146 mm) 7-1/4” (184 mm) 10-1/4” (260 mm) 12-1/4” (311 mm) 13-1/4” (337 mm) 14-3/4” ...

  • Lennox Hearth MONTEST - page 17

    Figure 28 OFFSET CHIMNEY INST ALLA TION Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 29 Roof Support Note: In cold areas it is recommended to protect the chimney in a insulated chase. Straps Chimney ACBI ACBI Starter Section Straps Outside Wall OFFSET CHIMNEY INST ALLA TION WITH WALL PENETR ...

  • Lennox Hearth MONTEST - page 18

    ANGLED WALL RADIA TION SHIELD (XRSMI30 and AC10RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled fi restop or wall radiation shield must be installed. Only one is required. Note: 45º angle for Canada only (XRSMI45). In cold climate locations (climates where temperatures will fall below 32º F / 0º C), ...

  • Lennox Hearth MONTEST - page 19

    INST ALLA TION INSTRUCTIONS FOR MASONRY APPLICA TION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualifi ed chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit corr ...

  • Lennox Hearth MONTEST - page 20

    CHIMNEY - P ARTS AND COMPONENTS LISTS Secure T emp GX - 2” Insulated Galvanized Chimney System (Recommended Insulated System) Galvanized (7” ID & 11” OD) U.S.A. ONL Y Description Cat./Part No. Lengths & Misc. Chimney Components Length 8”, 7GXL8 7GXL8 Length 12”, 7GXL12 7GXL12 Length 18”, 7GXL18 7GXL18 Length 24”, 7GXL24 7GXL24 ...

  • Lennox Hearth MONTEST - page 21

    ACBI Chimney* (7” I.D., 13” O.D. AC - Air Cooled) * AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates (climates where temperatures will fall below 32° F / 0° C). Description Cat./Part No. One of the following adaptors is required if installing an AC chimney system Starter Section w/ air intake, 7” Dia., ACBI7S ...

  • Lennox Hearth MONTEST - page 22

    CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: • Side wall (fi replace front): 24” (457 mm) measured from the fi replace side. • Ceiling: 6’ 8” (2,032 mm) measured from the base of the fi replace • Fireplace enclosure: Bottom: 0” Side: 0” Back: 0” • T op: Do not fi l ...

  • Lennox Hearth MONTEST - page 23

    NOTES 23 ...

  • Lennox Hearth MONTEST - page 24

    Printed in Canada © 2006 by LENNOX HEARTH PRODUCTS P/N 850,038M REV . A 05/2006 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information. LHP 1110 West T aft Ave ...

Fabricant Lennox Hearth Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilLennox Hearth MONTEST peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lennox Hearth
- manuels d’utilisations MONTEST
- fiches produit Lennox Hearth
- dépliants
- ou étiquettes-énergie Lennox Hearth MONTEST
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lennox Hearth MONTEST.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lennox Hearth MONTEST, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lennox Hearth MONTEST. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lennox Hearth MONTEST.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Lennox Hearth MONTEST, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lennox Hearth MONTEST par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lennox Hearth MONTEST.

Le manuel d’utilisation complet Lennox Hearth, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lennox Hearth MONTEST - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lennox Hearth MONTEST, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLennox Hearth MONTEST qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lennox Hearth MONTEST - qui devraient nous aider dans les premières étapes lors de l'utilisation Lennox Hearth MONTEST
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lennox Hearth MONTEST
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lennox Hearth MONTEST dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lennox Hearth MONTEST?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lennox Hearth MONTEST, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lennox Hearth MONTEST il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)