Manual de instrucciones Fluke PN 2063508

31 de páginas 0.76 mb
Descargar

Pasar a la página of 31

Summary
  • Fluke PN 2063508 - page 1

    ® PN 2063508 January 2003 © 2003 Fluke C orpor ation. Al l rig hts reserv ed. P rinted in Chin a. All produc t nam es are tr adem arks of the ir res pective c ompa nies. 12 Multimete r Users Manual ...

  • Fluke PN 2063508 - page 2

    i Table of Contents Title Page READ FIRST: SAFETY INFORMATION .................................................... 1 SYMBOLS .................................................................................................. 2 DISPLAY .................................................................................................... 3 OPERATING FEA ...

  • Fluke PN 2063508 - page 3

    12 Multimeter Users M anual ii Recording Min imum and Max imum Readi ng with El apsed Tim e ............ 19 Capturing Con tinuity Interm ittents with Cont inuity Capture  .................. 21 TURNING BEEPER OFF............................................................................ 23 MAINTENANCE............................................. ...

  • Fluke PN 2063508 - page 4

    1 READ FIRST: SAFETY INFORMATION This meter has been des igned a nd tested i n acc ordance wit h IEC Publicat ion 1010 . To ensure that th e meter is used s afely, follow all s afety an d operating i nstruc tions in this manual. If th e meter is n ot used as desc ribed in th is manua l, the s afety features of the meter might be im paired. W Warnin ...

  • Fluke PN 2063508 - page 5

    12 Multimeter Users Manual 2 SYMBOLS The followi ng inter nationa l elec trical sy mbols are us ed in t his m anual: W Important Safe ty Informat ion in Manual ∅ Not Applic able to I dentifie d Model B AC F DC G Diode E Capacitor J Ground T Double Insulat ion ...

  • Fluke PN 2063508 - page 6

    12 Multimeter DISPL AY 3 DISPLAY Figure 1. D isplay ...

  • Fluke PN 2063508 - page 7

    12 Multimeter Users Manual 4 OPERATING FEATURES Figure 2. Operating Features ...

  • Fluke PN 2063508 - page 8

    12 Multimeter STAND BY MOD E 5 STANDBY MOD E In standby m ode, the dis play goes blank to preserv e battery life. Th e meter beeps and enters Standby if it is O N but inac tive f or more than 45 minutes . Press any pushbu tton to resume op eration. Standby is n ot allowe d if the met er is in the MIN M AX mode. INPUT RANGES The input r ange determ ...

  • Fluke PN 2063508 - page 9

    12 Multimeter Users Manual 6 Autoranging The meter defa ults to autor ange w hen you tur n it on. I n autora nge, the m eter selec ts the range autom atic ally. Manually Selecting a Range The meter als o has a m anual ran ge mode. In m anual rang e, you s elect and lock the meter in a ran ge. To manua lly s elect a r ange: 1. Press [ V ]. The meter ...

  • Fluke PN 2063508 - page 10

    12 Multimeter MEASURI NG VOLTAGE 7 MEASURING VOLTAGE 1. Inser t the test l eads i n the ja cks. 2. To select a voltage function, pu t the s lide-s witch in t he middle position. Se e Figure 3. To toggle betw een dc and ac, pr ess [ g ]. 3. Touch the probes to th e test po ints, and r ead the display . The meter beeps an Overload Aler t™ when O L ...

  • Fluke PN 2063508 - page 11

    12 Multimeter Users Manual 8 Figure 3. Measuring Vo ltage ...

  • Fluke PN 2063508 - page 12

    12 Multimeter TESTI NG CONTINUITY A ND MEAS URI NG RESISTANCE 9 TESTING CONTINUITY AND M EASURING RESISTANC E 1. Inser t the test l eads i n the ja cks, and turn off power t o the circ uit under test. External volt age ac ross the c omponents c auses inv alid readin gs. 2. Put the slide-switch i n the c ontinuity/o hms pos ition (Figur e 4). To tog ...

  • Fluke PN 2063508 - page 13

    12 Multimeter Users Manual 10 Figure 4. Continuity and Res istance Measurements ...

  • Fluke PN 2063508 - page 14

    12 Multimeter TESTING DIOD ES 11 TESTING DIOD ES 1. Inser t the test l eads i n the ja cks. 2. Put the slide-switch i n the c ontinuity/o hms pos ition. The m eter selec ts eit her the continuity /diode ( R G ) or ohm s ( e ) f unction. If ohms is select ed, pres s [ g ] to toggle to th e conti nuity/diode functi on. To to ggle the beeper on or off ...

  • Fluke PN 2063508 - page 15

    12 Multimeter Users Manual 12 Figure 5. Test ing Diodes ...

  • Fluke PN 2063508 - page 16

    12 Multimeter VCHEK A N D HOW TO USE IT 13 VCHEK AND HO W TO USE IT i is a subs et of the con tinuity /ohms func tion. In i , th e meter is designed t o automatical ly display an ac or dc volt age when the meter detec ts a vo ltage gre ater in magnitude th an about 4.5 V and the meter is not in the manual range m ode. THIS WILL NOT HARM THE METER. ...

  • Fluke PN 2063508 - page 17

    12 Multimeter Users Manual 14 Use i only on power s uppli es and other power sourc es that hav e a low output impedance. D o not us e i to m easure volt age in e lectronic c ircuitry u nless a 2 k e load will not damage the circ uit. See † on pag e 27. DISABLING i WITH FUNCTION LOCK To lock the m eter in eit her the c ontinui ty/diode or ohms fun ...

  • Fluke PN 2063508 - page 18

    12 Multimeter MEAS URI NG CAPACITANCE 15 MEASURING CAPACITA NCE First, turn off p ower to the circuit, a nd dis connect and discharge the ca pacitor. 1. Insert test leads, an d move the slide-sw itch to [ E ]. (See Figure 6 .) 2. Press [ E ]. The capac itance func tion is select ed and µF is dis played . 3. Touch the prob es to th e capacit or. Wh ...

  • Fluke PN 2063508 - page 19

    12 Multimeter Users Manual 16 Figure 6. Measuring Capacitance ...

  • Fluke PN 2063508 - page 20

    12 Multimeter USING MIN MAX FUNCTIO NS 17 USING MIN MAX FUNCTION S Recording Minimum and Maximum Readings MIN MAX rec ords the highes t and lowes t measurem ents taken. MIN M AX cannot be used when the meter is measuring capacita nce. In t he MIN M AX mode, autora nging, Standby, and i are dis able d. 1. Insert the test leads , and put the meter i ...

  • Fluke PN 2063508 - page 21

    12 Multimeter Users Manual 18 Figure 7. Displaying Minimum and Maximum Reading ...

  • Fluke PN 2063508 - page 22

    12 Multimeter USING MIN MAX FUNCTIO NS 19 Recording Minimum and Maximum Reading with Elapsed Time The MIN MAX w ith elapsed-t ime mode r ecords the t ime (in hours and m inutes) between when M IN MAX was entered and the last high a nd low w as recorded . Time is kept to 99:59. OL is dis played for longer t imes . 1. To enable the MIN MAX el apsed-t ...

  • Fluke PN 2063508 - page 23

    12 Multimeter Users Manual 20 Figure 8. Maximum and Minimum Reading with Elapsed Time ...

  • Fluke PN 2063508 - page 24

    12 Multimeter USING MIN MAX FUNCTIO NS 21 Capturing Continuity Intermittents with Continuity Capture When testing c ontin uity, the m eter can cap ture intermittents as short as 250 µs, and display them as open-t o-short a nd short-to-op en trans itions . 1. Put the slide-s witch i n the conti nuity/o hms pos ition. 2. Connect th e leads to t he c ...

  • Fluke PN 2063508 - page 25

    12 Multimeter Users Manual 22 Figur e 9. Open-to-Sh o r t and Sho r t-to -Op en Tran siti ons ...

  • Fluke PN 2063508 - page 26

    12 Multimeter TURNING BEE PER OFF 23 TURNING BEEPER OFF To disable a ll beep er func tions, pr ess and ho ld dow n [ Z ] for 2 second s whil e tu r ning the meter on. MAINTENANCE W Warning To avoid el ectrical sho ck or damag e to the m eter, do not g et water in side the case. Remov e the test l eads and any input signal s bef ore opening t he cas ...

  • Fluke PN 2063508 - page 27

    12 Multimeter Users Manual 24 Service and P arts This meter s hould be s erviced on ly by a qualified s ervice tec hnic ian. To order t he servic e manual (PN 900824) and oth er parts or for servic e inform ation, in th e USA call 1-800-825-9810. Outside t he USA, c ontact the neares t Fluke serv ice c enter. Accessories When using ac ces sories, p ...

  • Fluke PN 2063508 - page 28

    12 Multimeter SPECIF ICA TION S 25 Maximum Voltage Between any Terminal and Earth Ground 600 V rms Display 3 3/ 4-digits, 4000 counts , updates 4/sec Operating Temperature -10 °C to 50 °C Storage Temperature -30 °C to 60 °C indefinitely (to -40 °C for 100 hrs) Temperature Coefficient 0.1 x (specified accuracy )/°C (<18 °C or >28 °C) R ...

  • Fluke PN 2063508 - page 29

    12 Multimeter Users Manual 26 Functi on Range Resolu tion Accur acy (50 to 4 00 Hz) 4000 mV* 1 mV ±(1.9 %+3) 4.000 V 0.001 V ±(1.9 %+3) 40.00 V 0.01 V ±(1.9 %+3) 400.0 V 0.1 V ±(1.9 %+3) 600 V 1 V ±(1.9 %+3) 4000 mV* 1 mV ±(0.9 %+2) 4.000 V 0.001 V ±(0.9 %+2) 40.00 V 0.01 V ±(0.9 %+1) 400.0 V 0.1 V ±(0.9 %+1) 600 V 1 V ±(0.9 %+1) 400.0 ? ...

  • Fluke PN 2063508 - page 30

    12 Multimeter SPECIF ICA TION S 27 Functi on Overl oad Prote ction* Input Impe danc e (Nomi nal) Comm o n Mo de Rejection Ratio (1 k Ω Unbalan ce) Norma l Mode Rejection 600 V dc >10 M Ω < 100 pF † & Lo Z = >2 k Ω <200 pF >100 dB at dc, 50 Hz or 60 Hz >50 dB at 50 Hz or 60 Hz 600 V rms >5 M Ω < 100 pF † & ...

  • Fluke PN 2063508 - page 31

    12 Multimeter Users Manual 28 ...

Fabricante Fluke Categoría Weather Radio

Los documentos del dispositivo Fluke PN 2063508 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Fluke
- manuales de instrucciones PN 2063508
- hojas de producto Fluke
- folletos informativos
- o etiquetas energéticas Fluke PN 2063508
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Fluke PN 2063508.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Fluke PN 2063508, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Fluke PN 2063508. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Fluke PN 2063508.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Fluke PN 2063508, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Fluke PN 2063508. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Fluke PN 2063508.

El manual de instrucciones completo de Fluke debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Fluke PN 2063508 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Fluke PN 2063508, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Fluke PN 2063508 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Fluke PN 2063508 - que deben facilitarnos los primeros pasos durante el uso de Fluke PN 2063508
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Fluke PN 2063508
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Fluke PN 2063508 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Fluke PN 2063508?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Fluke PN 2063508, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Fluke PN 2063508 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)