Manuale per l’uso Fluke PN 2063508

31 pagine 0.76 mb
Scarica

Vai alla pagina of 31

Summary
  • Fluke PN 2063508 - page 1

    ® PN 2063508 January 2003 © 2003 Fluke C orpor ation. Al l rig hts reserv ed. P rinted in Chin a. All produc t nam es are tr adem arks of the ir res pective c ompa nies. 12 Multimete r Users Manual ...

  • Fluke PN 2063508 - page 2

    i Table of Contents Title Page READ FIRST: SAFETY INFORMATION .................................................... 1 SYMBOLS .................................................................................................. 2 DISPLAY .................................................................................................... 3 OPERATING FEA ...

  • Fluke PN 2063508 - page 3

    12 Multimeter Users M anual ii Recording Min imum and Max imum Readi ng with El apsed Tim e ............ 19 Capturing Con tinuity Interm ittents with Cont inuity Capture  .................. 21 TURNING BEEPER OFF............................................................................ 23 MAINTENANCE............................................. ...

  • Fluke PN 2063508 - page 4

    1 READ FIRST: SAFETY INFORMATION This meter has been des igned a nd tested i n acc ordance wit h IEC Publicat ion 1010 . To ensure that th e meter is used s afely, follow all s afety an d operating i nstruc tions in this manual. If th e meter is n ot used as desc ribed in th is manua l, the s afety features of the meter might be im paired. W Warnin ...

  • Fluke PN 2063508 - page 5

    12 Multimeter Users Manual 2 SYMBOLS The followi ng inter nationa l elec trical sy mbols are us ed in t his m anual: W Important Safe ty Informat ion in Manual ∅ Not Applic able to I dentifie d Model B AC F DC G Diode E Capacitor J Ground T Double Insulat ion ...

  • Fluke PN 2063508 - page 6

    12 Multimeter DISPL AY 3 DISPLAY Figure 1. D isplay ...

  • Fluke PN 2063508 - page 7

    12 Multimeter Users Manual 4 OPERATING FEATURES Figure 2. Operating Features ...

  • Fluke PN 2063508 - page 8

    12 Multimeter STAND BY MOD E 5 STANDBY MOD E In standby m ode, the dis play goes blank to preserv e battery life. Th e meter beeps and enters Standby if it is O N but inac tive f or more than 45 minutes . Press any pushbu tton to resume op eration. Standby is n ot allowe d if the met er is in the MIN M AX mode. INPUT RANGES The input r ange determ ...

  • Fluke PN 2063508 - page 9

    12 Multimeter Users Manual 6 Autoranging The meter defa ults to autor ange w hen you tur n it on. I n autora nge, the m eter selec ts the range autom atic ally. Manually Selecting a Range The meter als o has a m anual ran ge mode. In m anual rang e, you s elect and lock the meter in a ran ge. To manua lly s elect a r ange: 1. Press [ V ]. The meter ...

  • Fluke PN 2063508 - page 10

    12 Multimeter MEASURI NG VOLTAGE 7 MEASURING VOLTAGE 1. Inser t the test l eads i n the ja cks. 2. To select a voltage function, pu t the s lide-s witch in t he middle position. Se e Figure 3. To toggle betw een dc and ac, pr ess [ g ]. 3. Touch the probes to th e test po ints, and r ead the display . The meter beeps an Overload Aler t™ when O L ...

  • Fluke PN 2063508 - page 11

    12 Multimeter Users Manual 8 Figure 3. Measuring Vo ltage ...

  • Fluke PN 2063508 - page 12

    12 Multimeter TESTI NG CONTINUITY A ND MEAS URI NG RESISTANCE 9 TESTING CONTINUITY AND M EASURING RESISTANC E 1. Inser t the test l eads i n the ja cks, and turn off power t o the circ uit under test. External volt age ac ross the c omponents c auses inv alid readin gs. 2. Put the slide-switch i n the c ontinuity/o hms pos ition (Figur e 4). To tog ...

  • Fluke PN 2063508 - page 13

    12 Multimeter Users Manual 10 Figure 4. Continuity and Res istance Measurements ...

  • Fluke PN 2063508 - page 14

    12 Multimeter TESTING DIOD ES 11 TESTING DIOD ES 1. Inser t the test l eads i n the ja cks. 2. Put the slide-switch i n the c ontinuity/o hms pos ition. The m eter selec ts eit her the continuity /diode ( R G ) or ohm s ( e ) f unction. If ohms is select ed, pres s [ g ] to toggle to th e conti nuity/diode functi on. To to ggle the beeper on or off ...

  • Fluke PN 2063508 - page 15

    12 Multimeter Users Manual 12 Figure 5. Test ing Diodes ...

  • Fluke PN 2063508 - page 16

    12 Multimeter VCHEK A N D HOW TO USE IT 13 VCHEK AND HO W TO USE IT i is a subs et of the con tinuity /ohms func tion. In i , th e meter is designed t o automatical ly display an ac or dc volt age when the meter detec ts a vo ltage gre ater in magnitude th an about 4.5 V and the meter is not in the manual range m ode. THIS WILL NOT HARM THE METER. ...

  • Fluke PN 2063508 - page 17

    12 Multimeter Users Manual 14 Use i only on power s uppli es and other power sourc es that hav e a low output impedance. D o not us e i to m easure volt age in e lectronic c ircuitry u nless a 2 k e load will not damage the circ uit. See † on pag e 27. DISABLING i WITH FUNCTION LOCK To lock the m eter in eit her the c ontinui ty/diode or ohms fun ...

  • Fluke PN 2063508 - page 18

    12 Multimeter MEAS URI NG CAPACITANCE 15 MEASURING CAPACITA NCE First, turn off p ower to the circuit, a nd dis connect and discharge the ca pacitor. 1. Insert test leads, an d move the slide-sw itch to [ E ]. (See Figure 6 .) 2. Press [ E ]. The capac itance func tion is select ed and µF is dis played . 3. Touch the prob es to th e capacit or. Wh ...

  • Fluke PN 2063508 - page 19

    12 Multimeter Users Manual 16 Figure 6. Measuring Capacitance ...

  • Fluke PN 2063508 - page 20

    12 Multimeter USING MIN MAX FUNCTIO NS 17 USING MIN MAX FUNCTION S Recording Minimum and Maximum Readings MIN MAX rec ords the highes t and lowes t measurem ents taken. MIN M AX cannot be used when the meter is measuring capacita nce. In t he MIN M AX mode, autora nging, Standby, and i are dis able d. 1. Insert the test leads , and put the meter i ...

  • Fluke PN 2063508 - page 21

    12 Multimeter Users Manual 18 Figure 7. Displaying Minimum and Maximum Reading ...

  • Fluke PN 2063508 - page 22

    12 Multimeter USING MIN MAX FUNCTIO NS 19 Recording Minimum and Maximum Reading with Elapsed Time The MIN MAX w ith elapsed-t ime mode r ecords the t ime (in hours and m inutes) between when M IN MAX was entered and the last high a nd low w as recorded . Time is kept to 99:59. OL is dis played for longer t imes . 1. To enable the MIN MAX el apsed-t ...

  • Fluke PN 2063508 - page 23

    12 Multimeter Users Manual 20 Figure 8. Maximum and Minimum Reading with Elapsed Time ...

  • Fluke PN 2063508 - page 24

    12 Multimeter USING MIN MAX FUNCTIO NS 21 Capturing Continuity Intermittents with Continuity Capture When testing c ontin uity, the m eter can cap ture intermittents as short as 250 µs, and display them as open-t o-short a nd short-to-op en trans itions . 1. Put the slide-s witch i n the conti nuity/o hms pos ition. 2. Connect th e leads to t he c ...

  • Fluke PN 2063508 - page 25

    12 Multimeter Users Manual 22 Figur e 9. Open-to-Sh o r t and Sho r t-to -Op en Tran siti ons ...

  • Fluke PN 2063508 - page 26

    12 Multimeter TURNING BEE PER OFF 23 TURNING BEEPER OFF To disable a ll beep er func tions, pr ess and ho ld dow n [ Z ] for 2 second s whil e tu r ning the meter on. MAINTENANCE W Warning To avoid el ectrical sho ck or damag e to the m eter, do not g et water in side the case. Remov e the test l eads and any input signal s bef ore opening t he cas ...

  • Fluke PN 2063508 - page 27

    12 Multimeter Users Manual 24 Service and P arts This meter s hould be s erviced on ly by a qualified s ervice tec hnic ian. To order t he servic e manual (PN 900824) and oth er parts or for servic e inform ation, in th e USA call 1-800-825-9810. Outside t he USA, c ontact the neares t Fluke serv ice c enter. Accessories When using ac ces sories, p ...

  • Fluke PN 2063508 - page 28

    12 Multimeter SPECIF ICA TION S 25 Maximum Voltage Between any Terminal and Earth Ground 600 V rms Display 3 3/ 4-digits, 4000 counts , updates 4/sec Operating Temperature -10 °C to 50 °C Storage Temperature -30 °C to 60 °C indefinitely (to -40 °C for 100 hrs) Temperature Coefficient 0.1 x (specified accuracy )/°C (<18 °C or >28 °C) R ...

  • Fluke PN 2063508 - page 29

    12 Multimeter Users Manual 26 Functi on Range Resolu tion Accur acy (50 to 4 00 Hz) 4000 mV* 1 mV ±(1.9 %+3) 4.000 V 0.001 V ±(1.9 %+3) 40.00 V 0.01 V ±(1.9 %+3) 400.0 V 0.1 V ±(1.9 %+3) 600 V 1 V ±(1.9 %+3) 4000 mV* 1 mV ±(0.9 %+2) 4.000 V 0.001 V ±(0.9 %+2) 40.00 V 0.01 V ±(0.9 %+1) 400.0 V 0.1 V ±(0.9 %+1) 600 V 1 V ±(0.9 %+1) 400.0 ? ...

  • Fluke PN 2063508 - page 30

    12 Multimeter SPECIF ICA TION S 27 Functi on Overl oad Prote ction* Input Impe danc e (Nomi nal) Comm o n Mo de Rejection Ratio (1 k Ω Unbalan ce) Norma l Mode Rejection 600 V dc >10 M Ω < 100 pF † & Lo Z = >2 k Ω <200 pF >100 dB at dc, 50 Hz or 60 Hz >50 dB at 50 Hz or 60 Hz 600 V rms >5 M Ω < 100 pF † & ...

  • Fluke PN 2063508 - page 31

    12 Multimeter Users Manual 28 ...

Fabbricante Fluke Categoria Weather Radio

I documenti che otteniamo dal fabbricante del dispositivoFluke PN 2063508 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Fluke
- manuali per l’uso PN 2063508
- schede prodotto Fluke
- opuscoli
- o etichette energetiche Fluke PN 2063508
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Fluke PN 2063508.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Fluke PN 2063508, manuali di manutenzione, brevi manuali o manuali utente Fluke PN 2063508. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Fluke PN 2063508.

Manuali per l’uso simili

Manuale completo del dispositivo Fluke PN 2063508, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Fluke PN 2063508 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Fluke PN 2063508.

Il manuale per l’uso completo Fluke, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Fluke PN 2063508 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Fluke PN 2063508, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Fluke PN 2063508 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Fluke PN 2063508 - che ci dovrebbe aiutare nei primi passi durante l'uso Fluke PN 2063508
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Fluke PN 2063508
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Fluke PN 2063508 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Fluke PN 2063508?

Utilizza il modulo sottostante

Se non hai risolto il problema con Fluke PN 2063508 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Fluke PN 2063508 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)