  • Sanyo ECOi - page 1

    ECOi TM V ariable R efrigerant Flo w (VRF), Multi-Zone, Heat P ump & Heat R eco v er y S y stems ...

  • Sanyo ECOi - page 2

    INTRODUCTION.. ..................................................2 ECOi™ Building Y our Business..................................3 ECOi™ . Y our Building Life T ool ..................................4 SANY O OUTDOOR Units ..................................6 3 Pipe VRF Heat Recovery ................................6 ECOi Mini VRF .............. ...

  • Sanyo ECOi - page 3

    INTRODUCTION E CO i™ . B u i l d i ng Y o u r B u s i n e s s . SANY O's Brand V ision SANYO HV AC consistently builds new ideas to help build your business. By delivering multi-zone options, space-saving and environmentally friendly designs, our solutions are evolving, improving solutions. Flexible Combinations: ECOi allows multiple indoor ...

  • Sanyo ECOi - page 4

    Contractors. Buil ding Support. At SANYO, we realize contractors are looking for turnkey installation and support. ECOi™ is quite simply the perfect building solution. With its modular design and ease of installation, it’ s a solution that can grow with any building project. In fact, ECOi may just make you remember why you got into the business ...

  • Sanyo ECOi - page 5

    INTRODUCTION For th e b ui ldi ngs re qui ri ng sim ult ane ou s h eat ing an d coo lin g, SANYO 3-Way ECOi™ system provides the perfect solution 05 05 C o m m e r ci a l o f f i c e b u i l d i n g s a r e s u b j e c t t o f l uc t ua t i n g h e a t l e v e l s g e n e r a t e d f r o m e l e c t r on ic o f f i c e e q u i p m e n t , ligh t ...

  • Sanyo ECOi - page 6

    MODELS (T ype: Nominal Cooling Capacity , etc) V olt PH CHDZ 07263 72,000 BTU Heat Recovery 208-230V/60 HZ 3 CHDZ R07263 72,000 BTU Heat Recovery W ith Salt Protection - Special Order 208-230V/60 HZ 3 CHDZ 09663 96,000 BTU Heat Recovery 208-230V/60 HZ 3 CHDZ R09663 96,000 BTU Heat Recovery W ith Salt Protection - Special Order 208-230V/60 HZ 3 CHDZ ...

  • Sanyo ECOi - page 7

    SANY O OUTDOOR 07 DESCRIPTION CHDZ (R) 07263 CHDZ (R) 09663 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW 72,000 5.3 81,000 5.79 96,000 7.75 108,000 8.6 ELECTRICAL RA TINGS VOL T AG E R A TING COOLING RUNNING AMPERES HEA TING RUNNING AMPERES MIN. CIRCUIT AMP ACITY MAX. CIRCUIT AMP ACITY 208 - 230 ...

  • Sanyo ECOi - page 8

    WCHDZ 14463 / WCHDZ 16863 / WCHDZ 19263 WCHDZ 21663 / WCHDZ 24063 WCHDZ 26463 / WCHDZ 28863 K E Y F E AT U R E S : * T hre e -Way H ea t Re c ov er y * Co mbin e 3 ou td oor u nit s up t o 24 tons * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 3 Ph ase, 6 0 H z * Mult iple C omp r es so rs F o r E x tr a Reliabilit y and P ar ti ...

  • Sanyo ECOi - page 9

    SANY O OUTDOOR 09 WCHDZ SERIES 3-W ay ECOi VRF Heat Recov ery Combined Units DESCRIPTION WCHDZ 14463 WCHDZ 16863 WCHDZ 19263 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (1) CHDZ07263 and (1) CHDZ07263 144,000 10.56 162,000 11.58 includes (1)CHDZ07263 and (1) CHDZ09663 168,000 12.97 189, ...

  • Sanyo ECOi - page 10

    WCHDZ SERIES 3-W ay ECOi VRF Heat Recov ery combined units DESCRIPTION WCHDZ 21663 WCHDZ 24063 WCHDZ 26463 WCHDZ 28863 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (3) CHDZ07263 216,000 15.84 243,000 17.37 includes (2) CHDZ07263 and (1) CHDZ09663 240,000 18.25 270,000 20.18 includes (1) ...

  • Sanyo ECOi - page 11

    11 SANYO’ s Mini ECOi is suited for numerous commercial and premium residential applications. SANY O OUTDOOR CHX SERIES Mini ECOi Multi Split VRF Heat Pump CHX (R) 03652 / CHX (R) 05252 K E Y F E AT U RE S : * Single P ha se 2 0 8 / 2 3 0 v olt s * One O u tdo or U nit C on ne c ts A s M an y A s 9 Ind oor U nit s ( 5 0 % -1 30 % r at io of ind o ...

  • Sanyo ECOi - page 12

    12 CHDX SERIES 2-W ay ECOi VRF Heat Pump DESCRIPTION (T ype: Nominal Cooling Capacity , etc) V olt PH CHDX 07263 * 72,000 BTU Heat Pump 208-230V/60 HZ 3 CHDX (R) 07263 * 72,000 BTU Heat Pump W ith Salt Protection - Special Order 208-230V/60 HZ 3 CHDX 09663 * 96,000 BTU Heat Pump 208-230V/60 HZ 3 CHDX (R) 09663 * 96,000 BTU Heat Pump W ith Salt Prot ...

  • Sanyo ECOi - page 13

    13 SANY O OUTDOOR CHDX SERIES 2- W ay ECOi VRF Heat Pump * NOTE : *460 V olt Step Down T ransformers (460-230) available for 6 and 8 ton condensers (R) indicates with salt protection - Special Order DESCRIPTION CHDX (R) 07263 CHDX (R) 09663 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW 72,000 5.28 ...

  • Sanyo ECOi - page 14

    14 WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units WCHDX 14463 / WCHDX 16863 / WCHDX 19263 WCHDX 21663 / WCHDX 24063 WCHDX 26463 / WCHDX 28863 K E Y F E AT U RE S : * He at P um p * Co mbin e 3 ou td oor u nit s up t o 24 tons * Co mbin ed S er ies A llow s Up t o 4 0 In doo r Uni ts ( 5 0 % - 1 30 % ra tio of indo or t o ou td oor c ap a ...

  • Sanyo ECOi - page 15

    15 SANY O OUTDOOR WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units DESCRIPTION WCHDX 14463 WCHDX 16863 WCHDX 19263 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (2) CHDX07263 144,000 10.56 162,000 11.58 includes (1) CHDX07263 and (1) CHDX09663 168,000 12.97 189,000 14.39 includes ...

  • Sanyo ECOi - page 16

    16 WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units DESCRIPTION WCHDX 21663 WCHDX 24063 WCHDX 26463 WCHDX 28863 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (3) CHDX07263 216,000 15.84 243,000 17.37 includes (2) CDDX07263 and (1) CHDX09663 240,000 18.25 270,000 20.18 includes (1) ...

  • Sanyo ECOi - page 17

    17 SANY O INDOOR KHX 0752 / KHX 0952 / KHX 1252 / KHX 1862 KHX 1962 / KHX 2452 / A TK-SVRK56BA K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * Ea sy Wall Mo un t for A n y A p plica tio n * W a s h a b l e L o n g L if e F i l t e r * E l e c t r on i c E x p a n s i o n V al v e ( E E V ...

  • Sanyo ECOi - page 18

    18 THX SERIES Ceiling Suspended Unit DESCRIPTION THX 1252 THX 1852 THX 2452 CAP ACIT Y COOLING HEA TING 12,000 BTU 14,000 BTU 19,000 BTU 21,000 BTU 25,000 BTU 27,000 BTU CUR REN T COOLING HEA TING 0.14/0.17 A 0.14/0.15 A 0.15/0.14 A 0.15/0.17 A 0.34/0.31 A 0.34/0.36 A POW ER INP UT COOLING HEA TING 15/16 W 15/16 W 16/16 W 16/18 W 38/37 W 40/40 W UN ...

  • Sanyo ECOi - page 19

    SYSTEM/MODEL Components (T ype: Nominal Cooling Capacity , etc) V olt PH 07 AHX 52 System 7500 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1 AHX 0752 cassette 208-230V/60 HZ 1 PNR-AH1252 grille 09 AHX 52 System 9000 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1 AHX 0952 cassette 208-230V/60 HZ 1 PNR-AH1252 grille 12 ...

  • Sanyo ECOi - page 20

    XMHX SERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump 4-W ay Ceiling Cassette 24" x 24", with Condensate Pump 12 XMHX 52 / 18 XMHX 52 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * F o u r Wa y A i r T h r o w * Wash able L on g Li fe A ir F ilter * B ui ...

  • Sanyo ECOi - page 21

    SANY O INDOOR XHX SERIES 4-W ay Ceiling Cassette 35" x 35", with Condensate Pump 24 XHX 52 / 36 XHX 52 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * F o u r Wa y A i r T h r o w * Wash able L on g Li fe A ir F ilter * B ui l t- In D r a i n P um p – 2 5 I n c h L i f t Po ss ...

  • Sanyo ECOi - page 22

    UMHX SERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump UMHX 0762 / UMHX 0962 / UMHX 1262 UMHX 1562 / UMHX 1862 K E Y F E AT U RE S : * “E C O Fr ie nd ly ” R 410A R e f ri ge ra n t * 20 8 / 2 3 0 V, 1 Pha se , 6 0 Hz * Ele c t r oni c E x p a nsi on Va lv e ( E E V ) fo r A c cur a t e Re f ri ge ra n t C on t ro l * Ad ...

  • Sanyo ECOi - page 23

    SANY O INDOOR UHX SERIES Concealed Ducted - Medium Static DESCRIPTION UHX 0762 UHX 0962 UHX 1262 UHX 1562 UHX 1862 UHX 2462 UHX 3662 UHX 4862 UHX 5462 PERFORMANCE COOL ING CAP A CITY HEA TING CAP ACITY 7,500 BTU/H 8,500 BTU/H 9,600 BTU/H 11,000 BTU/H 12,000 BTU/H 14,000 BTU/H 15,0 0 0 BTU/H 17 , 0 0 0 BTU/H 19,0 0 0 BTU/H 21,0 0 0 BTU/H 25 ,0 0 0 B ...

  • Sanyo ECOi - page 24

    DHX SERIES Concealed Ducted - Medium-High Static DESCRIPTION DHX 3652 DHX 4852 CAP ACIT Y COOLING HEA TING 36,000 BTU 39,000 BTU 47,800 BTU 54,600 BTU CUR REN T COOLING HEA TING 2.84/2.89 A 2.74/2.80 A 3.24/3.19 A 3.17/3.42 A POW ER INP UT COOLING HEA TING 548/620 W 528/602 W 644/695 W 627/756 W UNIT DIMENSIONS Inches (") / lbs. 16.5"/ 42 ...

  • Sanyo ECOi - page 25

    SANY O INDOOR FHX/FMHX SERIES Floor Mounted FMHX 0762 / FMHX 0962 / FMHX 1262 FMHX 1562 / FMHX 1862 / FMHX 2462 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * Ele ct r onic E xp an sion Valv e ( E E V ) fo r Ac cu ra te R ef r iger an t C on tr ol * Wir e d or W irel es s Rem ot e C on t ...

  • Sanyo ECOi - page 26

    CONTROL S Y S TEMS SANYO’ s system control network is the heart and soul of the ECOi™ unit, enabling it to live with the living inside. With a simple two-wire loop installation, we put co nt rol in yo ur ha nds , l ite ral ly . N o o uts id e spe cia lis ts re qui red , i t’ s a n all -in -on e s ol uti on for you, and a way to further build ...

  • Sanyo ECOi - page 27

    SANY O Control S ystem 27 CONTROL S Y S TEMS Simple System Control Network WIRED REMO TES SIMPLE TO INST ALL K E Y F E AT U RE S : ( S I M PL E RE M O T E ) * T hin and E as y T o Re ad * Simple T o Ins t all and Us e * Ca n Be A d ap te d fo r Us e On A ll EC Oi In doo r Unit s * Mo de * Operating Mode (Heating / Cooli ng/Au to / Dr y/ F an) * Vac ...

  • Sanyo ECOi - page 28

    CONTROL S Y S TEMS Simple System Control Network SHA-K T 2 5 6BA Intel l igent Controll er K E Y F E AT U RE S ( INT EL L IGENT CONT ROL) : * 6.5 Inc h T ouch Scr een P anel * Co ntr ols up to 2 5 6 Indo or unit s wi th ad ded C ommu nicat ion Ad apt er (1 28 indo ors w it hou t ) * N e w C o n t r ol W i r i n g S y s t e m ( S N e t ) C o n n e c ...

  • Sanyo ECOi - page 29

    SANY O Control S ystem 29 CONTROL S Y S TEMS Building Management Integration K E Y F E AT U RE S : * Co mmunica te W it h L onWork s Co mp atible Sy st ems * St ar t / St op * Co ntr ols Up T o 1 6 Groups ( Ma ximum 6 4 In door U nits ) * F o r 17 o r m or e g r o u p s o f in d o or u ni t s c on n e c t a d di t i o n a l inter fac e unit s. * T ...

  • Sanyo ECOi - page 30

    30 A CCESSORIES P ART NUMBER DESCRIPTION 2-W a y Distr ibution Kits (cut to fit) Simple System Control Network APR -P160UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - Up to 76,400 BTUs APR -P680UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - 76,500 to 232,000 BTUs APR -P1350UK DISTRIBUTION JOI ...

  • Sanyo ECOi - page 31

    31 SERVICES SER VICES Simple System Control Network P ART NUMBER DESCRIPTION ECO -SC-4 ECOi COMMISSIONING (Per normal business day , up to 24 tons) IC -SC-1 COMMISSIONING OF INTELLIGENT CONTROLLER (Base fee for each Intelligent Controller) IC -SC-INDOOR COMMISSIONING OF INTELLIGENT CONTROLLER (Indoor Units) LW -SC-1 COMMISSIONING OF LONWORKS INTERF ...

  • Sanyo ECOi - page 32

    Us age ○ T h e a i r c on d i t i o n e r s l i s t e d h e r e i n a r e o nl y f o r c o o l i n g / h e a t i n g a r e a s u s e d b y peo pl e. D o no t u se t h e un i t f or f oo ds , an ima ls , pla n t s, p r e ci si on m ac hi ne s, w o r k s o f a r t o r o t h e r o b j e c t s . D o i ng s o m a y c a u s e d a m a g e t o t h e u n ...

Fabricante Sanyo Categoría Work Light

Los documentos del dispositivo Sanyo ECOi que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Sanyo
- manuales de instrucciones ECOi
- hojas de producto Sanyo
- folletos informativos
- o etiquetas energéticas Sanyo ECOi
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Sanyo ECOi.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Sanyo ECOi, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Sanyo ECOi. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Sanyo ECOi.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Sanyo ECOi, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Sanyo ECOi. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Sanyo ECOi.

El manual de instrucciones completo de Sanyo debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Sanyo ECOi - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Sanyo ECOi, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Sanyo ECOi que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Sanyo ECOi - que deben facilitarnos los primeros pasos durante el uso de Sanyo ECOi
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Sanyo ECOi
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Sanyo ECOi en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Sanyo ECOi?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Sanyo ECOi, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Sanyo ECOi probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)