    ECOi TM V ariable R efrigerant Flo w (VRF), Multi-Zone, Heat P ump & Heat R eco v er y S y stems ...

  • Sanyo ECOi - page 2

    INTRODUCTION.. ..................................................2 ECOi™ Building Y our Business..................................3 ECOi™ . Y our Building Life T ool ..................................4 SANY O OUTDOOR Units ..................................6 3 Pipe VRF Heat Recovery ................................6 ECOi Mini VRF .............. ...

  • Sanyo ECOi - page 3

    INTRODUCTION E CO i™ . B u i l d i ng Y o u r B u s i n e s s . SANY O's Brand V ision SANYO HV AC consistently builds new ideas to help build your business. By delivering multi-zone options, space-saving and environmentally friendly designs, our solutions are evolving, improving solutions. Flexible Combinations: ECOi allows multiple indoor ...

  • Sanyo ECOi - page 4

    Contractors. Buil ding Support. At SANYO, we realize contractors are looking for turnkey installation and support. ECOi™ is quite simply the perfect building solution. With its modular design and ease of installation, it’ s a solution that can grow with any building project. In fact, ECOi may just make you remember why you got into the business ...

  • Sanyo ECOi - page 5

    INTRODUCTION For th e b ui ldi ngs re qui ri ng sim ult ane ou s h eat ing an d coo lin g, SANYO 3-Way ECOi™ system provides the perfect solution 05 05 C o m m e r ci a l o f f i c e b u i l d i n g s a r e s u b j e c t t o f l uc t ua t i n g h e a t l e v e l s g e n e r a t e d f r o m e l e c t r on ic o f f i c e e q u i p m e n t , ligh t ...

  • Sanyo ECOi - page 6

    MODELS (T ype: Nominal Cooling Capacity , etc) V olt PH CHDZ 07263 72,000 BTU Heat Recovery 208-230V/60 HZ 3 CHDZ R07263 72,000 BTU Heat Recovery W ith Salt Protection - Special Order 208-230V/60 HZ 3 CHDZ 09663 96,000 BTU Heat Recovery 208-230V/60 HZ 3 CHDZ R09663 96,000 BTU Heat Recovery W ith Salt Protection - Special Order 208-230V/60 HZ 3 CHDZ ...

  • Sanyo ECOi - page 7

    SANY O OUTDOOR 07 DESCRIPTION CHDZ (R) 07263 CHDZ (R) 09663 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW 72,000 5.3 81,000 5.79 96,000 7.75 108,000 8.6 ELECTRICAL RA TINGS VOL T AG E R A TING COOLING RUNNING AMPERES HEA TING RUNNING AMPERES MIN. CIRCUIT AMP ACITY MAX. CIRCUIT AMP ACITY 208 - 230 ...

  • Sanyo ECOi - page 8

    WCHDZ 14463 / WCHDZ 16863 / WCHDZ 19263 WCHDZ 21663 / WCHDZ 24063 WCHDZ 26463 / WCHDZ 28863 K E Y F E AT U R E S : * T hre e -Way H ea t Re c ov er y * Co mbin e 3 ou td oor u nit s up t o 24 tons * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 3 Ph ase, 6 0 H z * Mult iple C omp r es so rs F o r E x tr a Reliabilit y and P ar ti ...

  • Sanyo ECOi - page 9

    SANY O OUTDOOR 09 WCHDZ SERIES 3-W ay ECOi VRF Heat Recov ery Combined Units DESCRIPTION WCHDZ 14463 WCHDZ 16863 WCHDZ 19263 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (1) CHDZ07263 and (1) CHDZ07263 144,000 10.56 162,000 11.58 includes (1)CHDZ07263 and (1) CHDZ09663 168,000 12.97 189, ...

  • Sanyo ECOi - page 10

    WCHDZ SERIES 3-W ay ECOi VRF Heat Recov ery combined units DESCRIPTION WCHDZ 21663 WCHDZ 24063 WCHDZ 26463 WCHDZ 28863 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (3) CHDZ07263 216,000 15.84 243,000 17.37 includes (2) CHDZ07263 and (1) CHDZ09663 240,000 18.25 270,000 20.18 includes (1) ...

  • Sanyo ECOi - page 11

    11 SANYO’ s Mini ECOi is suited for numerous commercial and premium residential applications. SANY O OUTDOOR CHX SERIES Mini ECOi Multi Split VRF Heat Pump CHX (R) 03652 / CHX (R) 05252 K E Y F E AT U RE S : * Single P ha se 2 0 8 / 2 3 0 v olt s * One O u tdo or U nit C on ne c ts A s M an y A s 9 Ind oor U nit s ( 5 0 % -1 30 % r at io of ind o ...

  • Sanyo ECOi - page 12

    12 CHDX SERIES 2-W ay ECOi VRF Heat Pump DESCRIPTION (T ype: Nominal Cooling Capacity , etc) V olt PH CHDX 07263 * 72,000 BTU Heat Pump 208-230V/60 HZ 3 CHDX (R) 07263 * 72,000 BTU Heat Pump W ith Salt Protection - Special Order 208-230V/60 HZ 3 CHDX 09663 * 96,000 BTU Heat Pump 208-230V/60 HZ 3 CHDX (R) 09663 * 96,000 BTU Heat Pump W ith Salt Prot ...

  • Sanyo ECOi - page 13

    13 SANY O OUTDOOR CHDX SERIES 2- W ay ECOi VRF Heat Pump * NOTE : *460 V olt Step Down T ransformers (460-230) available for 6 and 8 ton condensers (R) indicates with salt protection - Special Order DESCRIPTION CHDX (R) 07263 CHDX (R) 09663 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW 72,000 5.28 ...

  • Sanyo ECOi - page 14

    14 WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units WCHDX 14463 / WCHDX 16863 / WCHDX 19263 WCHDX 21663 / WCHDX 24063 WCHDX 26463 / WCHDX 28863 K E Y F E AT U RE S : * He at P um p * Co mbin e 3 ou td oor u nit s up t o 24 tons * Co mbin ed S er ies A llow s Up t o 4 0 In doo r Uni ts ( 5 0 % - 1 30 % ra tio of indo or t o ou td oor c ap a ...

  • Sanyo ECOi - page 15

    15 SANY O OUTDOOR WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units DESCRIPTION WCHDX 14463 WCHDX 16863 WCHDX 19263 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (2) CHDX07263 144,000 10.56 162,000 11.58 includes (1) CHDX07263 and (1) CHDX09663 168,000 12.97 189,000 14.39 includes ...

  • Sanyo ECOi - page 16

    16 WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units DESCRIPTION WCHDX 21663 WCHDX 24063 WCHDX 26463 WCHDX 28863 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (3) CHDX07263 216,000 15.84 243,000 17.37 includes (2) CDDX07263 and (1) CHDX09663 240,000 18.25 270,000 20.18 includes (1) ...

  • Sanyo ECOi - page 17

    17 SANY O INDOOR KHX 0752 / KHX 0952 / KHX 1252 / KHX 1862 KHX 1962 / KHX 2452 / A TK-SVRK56BA K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * Ea sy Wall Mo un t for A n y A p plica tio n * W a s h a b l e L o n g L if e F i l t e r * E l e c t r on i c E x p a n s i o n V al v e ( E E V ...

  • Sanyo ECOi - page 18

    18 THX SERIES Ceiling Suspended Unit DESCRIPTION THX 1252 THX 1852 THX 2452 CAP ACIT Y COOLING HEA TING 12,000 BTU 14,000 BTU 19,000 BTU 21,000 BTU 25,000 BTU 27,000 BTU CUR REN T COOLING HEA TING 0.14/0.17 A 0.14/0.15 A 0.15/0.14 A 0.15/0.17 A 0.34/0.31 A 0.34/0.36 A POW ER INP UT COOLING HEA TING 15/16 W 15/16 W 16/16 W 16/18 W 38/37 W 40/40 W UN ...

  • Sanyo ECOi - page 19

    SYSTEM/MODEL Components (T ype: Nominal Cooling Capacity , etc) V olt PH 07 AHX 52 System 7500 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1 AHX 0752 cassette 208-230V/60 HZ 1 PNR-AH1252 grille 09 AHX 52 System 9000 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1 AHX 0952 cassette 208-230V/60 HZ 1 PNR-AH1252 grille 12 ...

  • Sanyo ECOi - page 20

    XMHX SERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump 4-W ay Ceiling Cassette 24" x 24", with Condensate Pump 12 XMHX 52 / 18 XMHX 52 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * F o u r Wa y A i r T h r o w * Wash able L on g Li fe A ir F ilter * B ui ...

  • Sanyo ECOi - page 21

    SANY O INDOOR XHX SERIES 4-W ay Ceiling Cassette 35" x 35", with Condensate Pump 24 XHX 52 / 36 XHX 52 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * F o u r Wa y A i r T h r o w * Wash able L on g Li fe A ir F ilter * B ui l t- In D r a i n P um p – 2 5 I n c h L i f t Po ss ...

  • Sanyo ECOi - page 22

    UMHX SERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump UMHX 0762 / UMHX 0962 / UMHX 1262 UMHX 1562 / UMHX 1862 K E Y F E AT U RE S : * “E C O Fr ie nd ly ” R 410A R e f ri ge ra n t * 20 8 / 2 3 0 V, 1 Pha se , 6 0 Hz * Ele c t r oni c E x p a nsi on Va lv e ( E E V ) fo r A c cur a t e Re f ri ge ra n t C on t ro l * Ad ...

  • Sanyo ECOi - page 23

    SANY O INDOOR UHX SERIES Concealed Ducted - Medium Static DESCRIPTION UHX 0762 UHX 0962 UHX 1262 UHX 1562 UHX 1862 UHX 2462 UHX 3662 UHX 4862 UHX 5462 PERFORMANCE COOL ING CAP A CITY HEA TING CAP ACITY 7,500 BTU/H 8,500 BTU/H 9,600 BTU/H 11,000 BTU/H 12,000 BTU/H 14,000 BTU/H 15,0 0 0 BTU/H 17 , 0 0 0 BTU/H 19,0 0 0 BTU/H 21,0 0 0 BTU/H 25 ,0 0 0 B ...

  • Sanyo ECOi - page 24

    DHX SERIES Concealed Ducted - Medium-High Static DESCRIPTION DHX 3652 DHX 4852 CAP ACIT Y COOLING HEA TING 36,000 BTU 39,000 BTU 47,800 BTU 54,600 BTU CUR REN T COOLING HEA TING 2.84/2.89 A 2.74/2.80 A 3.24/3.19 A 3.17/3.42 A POW ER INP UT COOLING HEA TING 548/620 W 528/602 W 644/695 W 627/756 W UNIT DIMENSIONS Inches (") / lbs. 16.5"/ 42 ...

  • Sanyo ECOi - page 25

    SANY O INDOOR FHX/FMHX SERIES Floor Mounted FMHX 0762 / FMHX 0962 / FMHX 1262 FMHX 1562 / FMHX 1862 / FMHX 2462 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H z * Ele ct r onic E xp an sion Valv e ( E E V ) fo r Ac cu ra te R ef r iger an t C on tr ol * Wir e d or W irel es s Rem ot e C on t ...

  • Sanyo ECOi - page 26

    CONTROL S Y S TEMS SANYO’ s system control network is the heart and soul of the ECOi™ unit, enabling it to live with the living inside. With a simple two-wire loop installation, we put co nt rol in yo ur ha nds , l ite ral ly . N o o uts id e spe cia lis ts re qui red , i t’ s a n all -in -on e s ol uti on for you, and a way to further build ...

  • Sanyo ECOi - page 27

    SANY O Control S ystem 27 CONTROL S Y S TEMS Simple System Control Network WIRED REMO TES SIMPLE TO INST ALL K E Y F E AT U RE S : ( S I M PL E RE M O T E ) * T hin and E as y T o Re ad * Simple T o Ins t all and Us e * Ca n Be A d ap te d fo r Us e On A ll EC Oi In doo r Unit s * Mo de * Operating Mode (Heating / Cooli ng/Au to / Dr y/ F an) * Vac ...

  • Sanyo ECOi - page 28

    CONTROL S Y S TEMS Simple System Control Network SHA-K T 2 5 6BA Intel l igent Controll er K E Y F E AT U RE S ( INT EL L IGENT CONT ROL) : * 6.5 Inc h T ouch Scr een P anel * Co ntr ols up to 2 5 6 Indo or unit s wi th ad ded C ommu nicat ion Ad apt er (1 28 indo ors w it hou t ) * N e w C o n t r ol W i r i n g S y s t e m ( S N e t ) C o n n e c ...

  • Sanyo ECOi - page 29

    SANY O Control S ystem 29 CONTROL S Y S TEMS Building Management Integration K E Y F E AT U RE S : * Co mmunica te W it h L onWork s Co mp atible Sy st ems * St ar t / St op * Co ntr ols Up T o 1 6 Groups ( Ma ximum 6 4 In door U nits ) * F o r 17 o r m or e g r o u p s o f in d o or u ni t s c on n e c t a d di t i o n a l inter fac e unit s. * T ...

  • Sanyo ECOi - page 30

    30 A CCESSORIES P ART NUMBER DESCRIPTION 2-W a y Distr ibution Kits (cut to fit) Simple System Control Network APR -P160UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - Up to 76,400 BTUs APR -P680UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - 76,500 to 232,000 BTUs APR -P1350UK DISTRIBUTION JOI ...

  • Sanyo ECOi - page 31

    31 SERVICES SER VICES Simple System Control Network P ART NUMBER DESCRIPTION ECO -SC-4 ECOi COMMISSIONING (Per normal business day , up to 24 tons) IC -SC-1 COMMISSIONING OF INTELLIGENT CONTROLLER (Base fee for each Intelligent Controller) IC -SC-INDOOR COMMISSIONING OF INTELLIGENT CONTROLLER (Indoor Units) LW -SC-1 COMMISSIONING OF LONWORKS INTERF ...

  • Sanyo ECOi - page 32

    Us age ○ T h e a i r c on d i t i o n e r s l i s t e d h e r e i n a r e o nl y f o r c o o l i n g / h e a t i n g a r e a s u s e d b y peo pl e. D o no t u se t h e un i t f or f oo ds , an ima ls , pla n t s, p r e ci si on m ac hi ne s, w o r k s o f a r t o r o t h e r o b j e c t s . D o i ng s o m a y c a u s e d a m a g e t o t h e u n ...

Fabricant Sanyo Catégorie Work Light

Les documents que nous recevons du fabricant de l'appareilSanyo ECOi peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Sanyo
- manuels d’utilisations ECOi
- fiches produit Sanyo
- dépliants
- ou étiquettes-énergie Sanyo ECOi
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Sanyo ECOi.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Sanyo ECOi, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Sanyo ECOi. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Sanyo ECOi.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Sanyo ECOi, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Sanyo ECOi par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Sanyo ECOi.

Le manuel d’utilisation complet Sanyo, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Sanyo ECOi - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Sanyo ECOi, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSanyo ECOi qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Sanyo ECOi - qui devraient nous aider dans les premières étapes lors de l'utilisation Sanyo ECOi
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Sanyo ECOi
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Sanyo ECOi dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Sanyo ECOi?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Sanyo ECOi, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Sanyo ECOi il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)