Manual de instrucciones Napoleon Fireplaces GD82PT-T

32 de páginas 2.98 mb
Descargar

Pasar a la página of 32

Summary
  • Napoleon Fireplaces GD82PT-T - page 1

    1 W415-0583 / D / 07.24.07 INST ALLA TION AND OPERA TION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED T O AND REMAIN WITH THE HOMEOWNER. GD82NT -T NA TURAL GAS GD82PT -T PROP ANE W ARN ...

  • Napoleon Fireplaces GD82PT-T - page 2

    2 W415-0583 / D / 07.24.07 PG 2-5 INTRODUCTION W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-9 VENTING V ent lengths V enting Specifi cations Air T erminal Locations 10-15 INST ALLA TION/FRAMING W all & Ceiling Protection Using Flexible V ent Components Fireplace V ent Connection Using Rigid V ...

  • Napoleon Fireplaces GD82PT-T - page 3

    3 W415-0583 / D / 07.24.07 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915. © WOLF STEEL L TD. N APOLEON® products are manuf actured under the strict Standard of the ...

  • Napoleon Fireplaces GD82PT-T - page 4

    4 W415-0583 / D / 07.24.07 Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition. Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the fi replace. Never obstruct the front opening of the fi replace. Objects placed in front ...

  • Napoleon Fireplaces GD82PT-T - page 5

    5 W415-0583 / D / 07.24.07 24" 16" 8" Do not use abrasive cleaners to clean glass. Buff lightly with a clean dry cloth. The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer . DO NOT SUB- STITUTE MA TERIALS. Clean the glass after the fi rst 10 hours of operation with a recommended gas fi replace ...

  • Napoleon Fireplaces GD82PT-T - page 6

    6 W415-0583 / D / 07.24.07 VER TICAL RISE IN FEET V T FIGURE 4 when (H T ) < (V T ) Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 90° elbow , the following formulas apply: F or mula 1: H T < V T ...

  • Napoleon Fireplaces GD82PT-T - page 7

    7 W415-0583 / D / 07.24.07 H 2 H 1 V 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .0 3 (t wo 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft H T + V T = 10.7 + 6 =16.7 Formula 1: H ...

  • Napoleon Fireplaces GD82PT-T - page 8

    8 W415-0583 / D / 07.24.07 REQUIRED VER TICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T when (H T ) < (V T ) FIGURE 9 For vent confi gurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply: F or mula 1: H T < V T F or mula 2: H T + V T < 40 feet See graph to ...

  • Napoleon Fireplaces GD82PT-T - page 9

    9 W415-0583 / D / 07.24.07 FIGURE 12 ...

  • Napoleon Fireplaces GD82PT-T - page 10

    10 W415-0583 / D / 07.24.07 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napoleon® dealer . See Accessories to order the specifi c kit required. 1 . Determine the air terminal location, cut and frame 1 1½ inch openings in the ceiling and the roof to provide the minimum cl ...

  • Napoleon Fireplaces GD82PT-T - page 11

    11 W415-0583 / D / 07.24.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. (Fig.a) 3. Stretch the ...

  • Napoleon Fireplaces GD82PT-T - page 12

    12 W415-0583 / D / 07.24.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws pro- vided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. 3. Apply high tempera ...

  • Napoleon Fireplaces GD82PT-T - page 13

    13 W415-0583 / D / 07.24.07 FLUE COLLAR RESTRICTOR PLA TE TOP OF THE FIREBOX Proceed once the vent installation is complete. Note : All gas connections must be contained within the fi replace when complete. 1. The fi replace is designed to accept a ½” gas supply line. The fi replace is equipped with a ½” manual shut-off valve, and an 18” ...

  • Napoleon Fireplaces GD82PT-T - page 14

    14 W415-0583 / D / 07.24.07 WARNING F acing and/or fi nishing material must ne ver o verhang into the fi replace opening. Do not distor t or force the fr ame kit components. W hen using a rough fi nish materi- al (i.e.; stone), maintain a ¼” - ½” bor der from the fr aming components. NON-COMBUSTIBLE FINISHING MA TERIAL 59 3 / 8 " 21 3 ...

  • Napoleon Fireplaces GD82PT-T - page 15

    15 W415-0583 / D / 07.24.07 FIGURE 32 MANTLE CLEARANCES 0 34 7 8 9 11 13 12 5 6 7 10 12 H E I G H T M A N T L E MANTLE WIDTH Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. Do NOT use the fi replace if any part has been under water . Call a qualified service technician IMMED ...

  • Napoleon Fireplaces GD82PT-T - page 16

    16 W415-0583 / D / 07.24.07 Optional Front Glass Door Latches Retainer Before the glass door can be removed, the optional front must be removed. The glass door is secured to the top front edge of the fi rebox. Pull the handles of the latches forward, then lift the hooks out from the slots in the door frame to release the top of the door . Next, pi ...

  • Napoleon Fireplaces GD82PT-T - page 17

    17 W415-0583 / D / 07.24.07 UNDERSIDE OF ROCK CLUSTER 3. Carefully place the rocks on the bowl by lining up the locating notch on the underside of the rock cluster with the opening in the rear of the bowl. (Fig. 39) FIGURE 37 FIGURE 38 TOP EDGES BOTTOM EDGES Next, remove the 6 screws that secure the burner base. Once the gas has been disconnected, ...

  • Napoleon Fireplaces GD82PT-T - page 18

    18 W415-0583 / D / 07.24.07 3. Remove optional front, glass door , bowl w/ rocks, burner , decorative panel, & burner bottom. 4. The blower mounting plate can now be removed. Remove the four screws that secure the plate to the fi rebox base. 5. The blower is secured to the fi rebox. Disconnect the wire connectors before attempting to remove t ...

  • Napoleon Fireplaces GD82PT-T - page 19

    19 W415-0583 / D / 07.24.07 Yo u r comes equipped with our Night Light TM . The light has been pre-wired and is controlled from the remote control. If in the event the lamp or lens needs to be replaced, follow the instructions below . Unplug the wire harness / transformer from the junction box inside the fi replace or turn off the electrical break ...

  • Napoleon Fireplaces GD82PT-T - page 20

    20 W415-0583 / D / 07.24.07 2. FLAME HEIGHT This function allows remote control of the fl ame height. Check that the Remote Control is on, otherwise, turn on the Remote Control and wait 5 seconds. Select the manual fl ame height until the cursor (small triangle) is to the left of the big fl ame. (Fig. 47) Use the RIGHT or LEFT button to set the ...

  • Napoleon Fireplaces GD82PT-T - page 21

    21 W415-0583 / D / 07.24.07 5. F AN SPEED SETTING This function controls the speed of the hot air circulating fan. T o change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6. TIMER SETTING The Remote Control has a sleep fu ...

  • Napoleon Fireplaces GD82PT-T - page 22

    22 W415-0583 / D / 07.24.07 ADDRESS SETTING PROCEDURE Use the UP and DOWN key on the transmitter until the cursor (small triangle) is left of the clock icon. From time 0:00 press the LEFT key ten times. The display will show then the trans- mitter address. Press the LEFT key to exit this function. The transmitter address is required to be equal to ...

  • Napoleon Fireplaces GD82PT-T - page 23

    23 W415-0583 / D / 07.24.07 DIP SWIT CH NUMBER (0 = ON / 1 = OFF) FIGURE 57 ...

  • Napoleon Fireplaces GD82PT-T - page 24

    24 W415-0583 / D / 07.24.07 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Use only your hand to turn the gas control ...

  • Napoleon Fireplaces GD82PT-T - page 25

    25 W415-0583 / D / 07.24.07 FIGURE 60 Adjust the pilot screw to provide properly sized fl ame. T urn in a clockwise direction to reduce the gas fl ow . FIGURE 61 ADJUSTMENTS PILO T BURNER ADJUSTMENT TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE. CAUTION: Label all wires prior to disconnection when servic- ing controls. Wiri ...

  • Napoleon Fireplaces GD82PT-T - page 26

    26 W415-0583 / D / 07.24.07 CONVERSION KIT This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruction is not followed exactly , a fi re, explosion or pro- duction ...

  • Napoleon Fireplaces GD82PT-T - page 27

    27 W415-0583 / D / 07.24.07 # P ART NO. DESCRIPTION 1 W135-0275 OUTER ROCKS 2 W135-0304 SINGLE ROCK 3 W135-0277 BOWL 4 GL-655 ROCK SET ASSEMBL Y 5 W565-0090 WIRE MESH 6* W390-0002 DOOR LA TCH ( EA ) 7 W725-0047 NA TURAL GAS V AL VE - MODULA TING 7 W725-0048 PROP ANE GAS V AL VE - MODULA TING 8* W455-0019 NA TURAL GAS ORIFICE #43 8* W455-0003 PROP A ...

  • Napoleon Fireplaces GD82PT-T - page 28

    28 W415-0583 / D / 07.24.07 35 34 16 48 46 45 22 19 28 18 20 AUX ON 0:00 00 ON/OFF FEATURE SELECT 21 25 23 24 26 1 2 17 4 11 9 13 12 10 54 40 41 42 43 55 39 3 5 ...

  • Napoleon Fireplaces GD82PT-T - page 29

    29 W415-0583 / D / 07.24.07 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked. Carbon is being de- posited on glass, ...

  • Napoleon Fireplaces GD82PT-T - page 30

    30 W415-0583 / D / 07.24.07 Remote wall switch is in “OFF” position; main burner comes on when gas knob is turned to “ON” position. W all switch is mounted upside down - reverse. Faulty valve. - replace. - replace. Remote wall switch is ground- ing. - check for ground (short); repair ground or replace wire. Remote wall switch wire is ground ...

  • Napoleon Fireplaces GD82PT-T - page 31

    31 W415-0583 / D / 07.24.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

  • Napoleon Fireplaces GD82PT-T - page 32

    32 W415-0583 / D / 07.24.07 NOTES ...

Fabricante Napoleon Fireplaces Categoría Printer Accessories

Los documentos del dispositivo Napoleon Fireplaces GD82PT-T que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Napoleon Fireplaces
- manuales de instrucciones GD82PT-T
- hojas de producto Napoleon Fireplaces
- folletos informativos
- o etiquetas energéticas Napoleon Fireplaces GD82PT-T
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Napoleon Fireplaces GD82PT-T.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Napoleon Fireplaces GD82PT-T, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Napoleon Fireplaces GD82PT-T. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Napoleon Fireplaces GD82PT-T.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Napoleon Fireplaces GD82PT-T, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Napoleon Fireplaces GD82PT-T. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Napoleon Fireplaces GD82PT-T.

El manual de instrucciones completo de Napoleon Fireplaces debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Napoleon Fireplaces GD82PT-T - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Napoleon Fireplaces GD82PT-T, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Napoleon Fireplaces GD82PT-T que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Napoleon Fireplaces GD82PT-T - que deben facilitarnos los primeros pasos durante el uso de Napoleon Fireplaces GD82PT-T
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Napoleon Fireplaces GD82PT-T
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Napoleon Fireplaces GD82PT-T en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Napoleon Fireplaces GD82PT-T?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Napoleon Fireplaces GD82PT-T, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Napoleon Fireplaces GD82PT-T probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)